The Effect of Corneal Biomechanical Properties on Rebound Tonometer in Patients With Normal-Tension Glaucoma

被引:37
|
作者
Shin, Jonghoon [1 ]
Lee, Ji-Woong [1 ,2 ,3 ]
Kim, Eun-Ah [3 ]
Caprioli, Joseph [3 ]
机构
[1] Pusan Natl Univ Hosp, Dept Ophthalmol, Pusan, South Korea
[2] Pusan Natl Univ Hosp, Med Res Inst, Pusan, South Korea
[3] Univ Calif Los Angeles, Sch Med, Jules Stein Eye Inst, Los Angeles, CA 90024 USA
关键词
OCULAR-RESPONSE-ANALYZER; OPEN-ANGLE GLAUCOMA; GOLDMANN APPLANATION TONOMETER; INTRAOCULAR-PRESSURE MEASUREMENTS; NORMAL EYES; THICKNESS; HYSTERESIS; LATANOPROST; HYPERTENSION; PROGRESSION;
D O I
10.1016/j.ajo.2014.10.007
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
center dot PURPOSE: To evaluate the effects of corneal biomechanical properties on intraocular pressure (IOP) measured with the ICare, and to compare IOP readings obtained with ICare, Ocular-Response Analyzer (ORA), and Goldmann applanation tonometry (GAT) in normal-tension glaucoma (NTG) and normal subjects. center dot DESIGN: Prospective, cross-sectional, comparative study. center dot METHODS: IOP was measured with ICare, ORA, and GAT. All subjects had corneal hysteresis (CH) and corneal resistance factor (CRF), which were measured with ORA; and central corneal thickness (CCT), axial length, spherical equivalent, and keratometry. center dot RESULTS: This study enrolled 97 eyes of 97 NTG patients and 89 eyes of 89 normal subjects. CCT, CH, and CRF in NTG patients were significantly lower than those in normal subjects (P = .033, P = .006, and P = .003). The difference in IOP between techniques was highly significant in NTG patients (P < .001), while there was no significant difference in IOP values between techniques in normal controls (P = .931). ICare readings were significantly lower than corneal-compensated IOP in NTG patients (P = .014). CH and CRF were significantly associated with IOP measurements with ICare in NTG and normal subjects (P < .001). The greater difference between IOPcc and ICare in NTG patients was significantly influenced by the lower CH (P < .001). center dot CONCLUSIONS: Since ICare is a convenient way to measure IOP, ICare is a reasonable option as an alternative tonometer in NTG patients. However, the clinician must consider that the corneal biomechanical characteristics in NTG can cause ICare to underestimate IOP. (C) 2015 by Elsevier Inc. All rights reserved.
引用
收藏
页码:144 / 154
页数:11
相关论文
共 50 条
  • [41] Normal-tension glaucoma: an update
    Barranco Esporcatte, Bruno Leonardo
    Tavares, Ivan Maynart
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2016, 79 (04) : 270 - 276
  • [42] SURGERY FOR NORMAL-TENSION GLAUCOMA
    HITCHINGS, RA
    WU, J
    POINOOSAWMY, D
    MCNAUGHT, A
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1995, 79 (05) : 402 - 406
  • [43] Normal-tension glaucoma history
    Lichter, PR
    OPHTHALMOLOGY, 2002, 109 (01) : 2 - 2
  • [44] Comparison of corneal biomechanical properties in normal tension glaucoma patients with different visual field progression speed
    Ying Hong
    Nobuyuki Shoji
    Tetsuya Morita
    Kazunori Hirasawa
    Kazuhiro Matsumura
    Masayuki Kasahara
    Kimiya Shimizu
    International Journal of Ophthalmology, 2016, 9 (07) : 973 - 978
  • [45] Corneal Thickness Measurements in Normal-tension Glaucoma Workups Is It Worth the Effort?
    Kurtz, Shimon
    Haber, Inbal
    Kesler, Anat
    JOURNAL OF GLAUCOMA, 2010, 19 (01) : 58 - 60
  • [46] Comparison of corneal biomechanical properties in normal tension glaucoma patients with different visual field progression speed
    Hong, Ying
    Shoji, Nobuyuki
    Morita, Tetsuya
    Hirasawa, Kazunori
    Matsumura, Kazuhiro
    Kasahara, Masayuki
    Shimizu, Kimiya
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2016, 9 (07) : 973 - 978
  • [47] Effect of betaxolol on primary open-angle glaucoma and normal-tension glaucoma patients
    Sacca, SC
    Macri, A
    Rolando, M
    Ciurlo, G
    JOURNAL OF OCULAR PHARMACOLOGY AND THERAPEUTICS, 1998, 14 (03) : 191 - 201
  • [48] Indocyanine green angiography in patients with normal-tension glaucoma
    Prunte, C
    OCULAR BLOOD FLOW: NEW INSIGHTS INTO THE PATHOGENESIS OF OCULAR DISEASES, 1996, : 189 - 194
  • [49] Effect of central corneal thickness on intraocular pressure with the rebound tonometer and the applanation tonometer in normal dogs
    Park, Young-Woo
    Jeong, Man-Bok
    Kim, Tae-Hyun
    Ahn, Jae-Sang
    Ahn, Jeong-Taek
    Park, Shin-Ae
    Kim, Se-Eun
    Seo, Kangmoon
    VETERINARY OPHTHALMOLOGY, 2011, 14 (03) : 169 - 173
  • [50] Results of Neuroimaging in Patients with Atypical Normal-Tension Glaucoma
    Kosior-Jarecka, Ewa
    Wrobel-Dudzinska, Dominika
    Pietura, Radoslaw
    Pankowska, Anna
    Szczuka, Beata
    Zarnowska, Iwona
    Lukasik, Urszula
    Zarnowski, Tomasz
    BIOMED RESEARCH INTERNATIONAL, 2020, 2020