The Effect of Corneal Biomechanical Properties on Rebound Tonometer in Patients With Normal-Tension Glaucoma

被引:37
|
作者
Shin, Jonghoon [1 ]
Lee, Ji-Woong [1 ,2 ,3 ]
Kim, Eun-Ah [3 ]
Caprioli, Joseph [3 ]
机构
[1] Pusan Natl Univ Hosp, Dept Ophthalmol, Pusan, South Korea
[2] Pusan Natl Univ Hosp, Med Res Inst, Pusan, South Korea
[3] Univ Calif Los Angeles, Sch Med, Jules Stein Eye Inst, Los Angeles, CA 90024 USA
关键词
OCULAR-RESPONSE-ANALYZER; OPEN-ANGLE GLAUCOMA; GOLDMANN APPLANATION TONOMETER; INTRAOCULAR-PRESSURE MEASUREMENTS; NORMAL EYES; THICKNESS; HYSTERESIS; LATANOPROST; HYPERTENSION; PROGRESSION;
D O I
10.1016/j.ajo.2014.10.007
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
center dot PURPOSE: To evaluate the effects of corneal biomechanical properties on intraocular pressure (IOP) measured with the ICare, and to compare IOP readings obtained with ICare, Ocular-Response Analyzer (ORA), and Goldmann applanation tonometry (GAT) in normal-tension glaucoma (NTG) and normal subjects. center dot DESIGN: Prospective, cross-sectional, comparative study. center dot METHODS: IOP was measured with ICare, ORA, and GAT. All subjects had corneal hysteresis (CH) and corneal resistance factor (CRF), which were measured with ORA; and central corneal thickness (CCT), axial length, spherical equivalent, and keratometry. center dot RESULTS: This study enrolled 97 eyes of 97 NTG patients and 89 eyes of 89 normal subjects. CCT, CH, and CRF in NTG patients were significantly lower than those in normal subjects (P = .033, P = .006, and P = .003). The difference in IOP between techniques was highly significant in NTG patients (P < .001), while there was no significant difference in IOP values between techniques in normal controls (P = .931). ICare readings were significantly lower than corneal-compensated IOP in NTG patients (P = .014). CH and CRF were significantly associated with IOP measurements with ICare in NTG and normal subjects (P < .001). The greater difference between IOPcc and ICare in NTG patients was significantly influenced by the lower CH (P < .001). center dot CONCLUSIONS: Since ICare is a convenient way to measure IOP, ICare is a reasonable option as an alternative tonometer in NTG patients. However, the clinician must consider that the corneal biomechanical characteristics in NTG can cause ICare to underestimate IOP. (C) 2015 by Elsevier Inc. All rights reserved.
引用
收藏
页码:144 / 154
页数:11
相关论文
共 50 条
  • [1] The Effect of Corneal Biomechanical Properties on Rebound Tonometer in Patients with Normal Tension Glaucoma
    Shin, Jong-Hoon
    Lee, Jiwoong
    Kim, Eun Ah
    Caprioli, Joseph
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [2] Corneal biomechanical properties in normal-tension glaucoma
    Morita, Tetsuya
    Shoji, Nobuyuki
    Kamiya, Kazutaka
    Fujimura, Fusako
    Shimizu, Kimiya
    ACTA OPHTHALMOLOGICA, 2012, 90 (01) : E48 - E53
  • [3] Significance of corneal biomechanical properties in patients with progressive normal-tension glaucoma
    Park, Jong Hyuk
    Jun, Roo Min
    Choi, Kyu-Ryong
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2015, 99 (06) : 746 - 751
  • [4] Relationship between corneal biomechanical properties and the structure of optic nerve head in patients with normal-tension glaucoma
    Shin, Jonghoon
    Lee, Jiwoong
    Kim, Eun-Ah
    Caprioli, Joseph
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [5] Relationship of axial length and corneal biomechanical properties with susceptibility to unilateral normal-tension glaucoma
    Ying-Yi Chen
    Tsing-Hong Wang
    Jehn-Yu Huang
    Chien-Chia Su
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2022, 260 : 255 - 264
  • [6] Relationship of axial length and corneal biomechanical properties with susceptibility to unilateral normal-tension glaucoma
    Chen, Ying-Yi
    Wang, Tsing-Hong
    Huang, Jehn-Yu
    Su, Chien-Chia
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2022, 260 (01) : 255 - 264
  • [7] Relationship between corneal biomechanical properties and structural biomarkers in patients with normal-tension glaucoma: a retrospective study
    Keunheung Park
    Jonghoon Shin
    Jiwoong Lee
    BMC Ophthalmology, 18
  • [8] Relationship between corneal biomechanical properties and structural biomarkers in patients with normal-tension glaucoma: a retrospective study
    Park, Keunheung
    Shin, Jonghoon
    Lee, Jiwoong
    BMC OPHTHALMOLOGY, 2018, 18
  • [9] Effect of Selective Laser Trabeculoplasty on Ocular Biomechanical Properties in Normal-Tension Glaucoma
    Kazemi, Arash
    Bui, Ngoc Thang
    Arthur, Xiaoming Zhang
    Sit, Arthur J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [10] Keratoconus and Normal-Tension Glaucoma: A Study of the Possible Association With Abnormal Biomechanical Properties as Measured by Corneal Hysteresis
    Cohen, Elisabeth J.
    Myers, Jonathan S.
    CORNEA, 2010, 29 (09) : 955 - 970