Characterization of a fast gas analyzer based on Raman scattering for the analysis of synthesis gas

被引:45
|
作者
Eichmann, S. C. [1 ,2 ]
Weschta, M. [1 ]
Kiefer, J. [3 ]
Seeger, T. [2 ,4 ]
Leipertz, A. [1 ,2 ]
机构
[1] Univ Erlangen Nurnberg, Lehrstuhl Tech Thermodynam, D-91058 Erlangen, Germany
[2] Erlangen Grad Sch Adv Opt Technol, D-91052 Erlangen, Germany
[3] Univ Aberdeen, Sch Engn, Aberdeen AB24 3UE, Scotland
[4] Lehrstuhl Thermodynam & Verbrennung, D-57072 Siegen, Germany
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2010年 / 81卷 / 12期
关键词
MIXTURE FORMATION PROCESS; DUAL-PUMP CARS; DIFFUSION FLAME; DIESEL-ENGINE; TEMPERATURE; H-2; SPECTROSCOPY; FRACTION;
D O I
10.1063/1.3521397
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A sensor system for fast analysis of synthesis gas (mixtures of CO and H(2)) is proposed and characterized. The system is based on spontaneous Raman scattering, which enables simultaneous concentration measurements of all relevant species. For typical synthesis gas applications, this system has to face large variations of temperature and pressure. In addition, strong fluctuations in mixture composition may occur, which lead to rather inconvenient signal intensities. In this paper, we describe a low resolution spectrometer designed to function as a synthesis gas sensor and characterize pressure and temperature effects on concentration measurements. In addition, the use of different spectral ranges and calibration strategies is investigated in view of measurement accuracy and precision. (C) 2010 American Institute of Physics. [doi:10.1063/1.3521397]
引用
收藏
页数:7
相关论文
共 50 条
  • [21] A new advanced infrared-based analyzer for fast analysis of ultra trace gas impurities
    Markowski, ML
    Dudek, J
    Lehmann, D
    Rabinowitz, P
    PROCEEDINGS OF THE 46TH ANNUAL ISA ANALYSIS DIVISION SYMPOSIUM, VOL 34, 2001, 410 : 121 - 130
  • [22] CLINICAL-EVALUATION OF A RAMAN-SCATTERING MULTIPLE GAS ANALYZER FOR THE OPERATING-ROOM
    WESTENSKOW, DR
    SMITH, KW
    COLEMAN, DL
    GREGONIS, DE
    VANWAGENEN, RA
    ANESTHESIOLOGY, 1989, 70 (02) : 350 - 355
  • [23] Gas Sensor for Volatile Anesthetic Agents Based on Raman Scattering
    Schlueter, Sebastian
    Popovska-Leipertz, Nadejda
    Seeger, Thomas
    Leipertz, Alfred
    LASER ASSISTED NET SHAPE ENGINEERING 7 (LANE 2012), 2012, 39 : 835 - 842
  • [24] Evaluation of the Metrological Characteristics of Raman Analyzer of Natural Gas
    Petrov, D. V.
    Matrosov, I. I.
    Zaripov, A. R.
    Tanichev, A. S.
    Kostenko, M. A.
    Nekhoroshev, A. O.
    MEASUREMENT TECHNIQUES, 2021, 64 (03) : 261 - 266
  • [25] Evaluation of the Metrological Characteristics of Raman Analyzer of Natural Gas
    D. V. Petrov
    I. I. Matrosov
    A. R. Zaripov
    A. S. Tanichev
    M. A. Kostenko
    A. O. Nekhoroshev
    Measurement Techniques, 2021, 64 : 261 - 266
  • [26] Polarisation of Raman scattering by hydrogen gas
    Bhagavantam, S
    NATURE, 1931, 128 : 70 - 70
  • [27] Double Raman Scattering In Gas Mixtures
    Verzhbitskiy, I. A.
    Chrysos, M.
    Kouzov, A. P.
    Rachet, F.
    20TH INTERNATIONAL CONFERENCE ON SPECTRAL LINE SHAPES, 2010, 1290 : 137 - +
  • [28] PNEUMATIC REFRACTOMETER - A CONTINUOUS FAST RECORDING GAS ANALYZER
    CLAMANN, HG
    FEDERATION PROCEEDINGS, 1952, 11 (01) : 25 - 25
  • [29] A Fast Exhaust-Gas Analyzer for the ITER Divertor
    Klepper, C. Christopher
    Carlson, Eric P.
    Moschella, John J.
    Hazelton, Robert C.
    Keitz, Michael D.
    2009 23RD IEEE/NPSS SYMPOSIUM ON FUSION ENGINEERING, 2009, : 213 - 216
  • [30] SCATTERING OF FAST ELECTRONS BY A GAS PLASMA
    BOERSCH, H
    GEIGER, J
    TOPSCHOWSKY, M
    ZEITSCHRIFT FUR NATURFORSCHUNG PART A-ASTROPHYSIK PHYSIK UND PHYSIKALISCHE CHEMIE, 1970, A 25 (10): : 1411 - +