Sensitive sandwich immunoassay based on single particle mode inductively coupled plasma mass spectrometry detection

被引:41
|
作者
Liu, Rui [1 ,2 ]
Xing, Zhi [1 ]
Lv, Yi [2 ]
Zhang, Sichun [1 ]
Zhang, Xinrong [1 ]
机构
[1] Tsinghua Univ, Dept Chem, Key Lab Atom & Mol Nanosci, Minist Educ, Beijing 100084, Peoples R China
[2] Sichuan Univ, Coll Chem, Minist Educ, Key Lab Green Chem & Technol, Chengdu 610064, Peoples R China
关键词
Inductively coupled plasma mass spectrometry (ICP-MS); Sandwich immunoassay; Single particle; Time resolved analysis; Colloidal gold; IgG; ATRIAL-NATRIURETIC-PEPTIDE; ELEMENT-TAGGED IMMUNOASSAY; ICP-MS; GOLD NANOPARTICLES; PROTEIN; COMBINATION; ANTIBODY; TAGS;
D O I
10.1016/j.talanta.2010.08.037
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive sandwich type immunoassay has been proposed with the detection by inductively coupled plasma mass spectrometry (ICP-MS) in a single particle mode (time resolved analysis) The signal induced by the flash of ions (Au-197(+)) due to the ionization of single Au-nanoparticle (Au-NP) label in the plasma torch can be measured by the mass spectrometer The frequency of the transient signals is proportional to the concentration of Au-NPs labels Characteristics of the signals obtained from Au-NPs of 20 45 and 80 nm in diameters were discussed The analytical figures for the determination of Au-labeled IgG using ICP-MS in conventional integral mode and single particle mode were compared in detail Rabbit-anti-human IgG was used as a model analyte in the sandwich immunoassay A detection limit (3 sigma) of 01 ng mL(-1) was obtained for rabbit-anti-human IgG after immunoreactions with a linear range of 0 3-10 ng mL(-1) and a RSD of 8 1% (2 0 ng mL(-1)) Finally the proposed method was successfully applied to spiked rabbit-anti-human IgG samples and rabbit-anti-human serum samples The method resulted to be a highly sensitive ICP-MS based sandwich type immunoassay (C) 2010 Elsevier B V All rights reserved
引用
收藏
页码:48 / 54
页数:7
相关论文
共 50 条
  • [41] Inductively coupled plasma mass spectrometry
    Beauchemin, D
    ANALYTICAL CHEMISTRY, 2004, 76 (12) : 3395 - 3415
  • [42] Inductively coupled plasma mass spectrometry
    Woeste, S
    LABORATORY MEDICINE, 2004, 35 (02) : 73 - 75
  • [43] Inductively coupled plasma mass spectrometry
    Beauchemin, Diane
    ANALYTICAL CHEMISTRY, 2006, 78 (12) : 4111 - 4135
  • [44] Inductively coupled plasma mass spectrometry
    Van Acker, Thibaut
    Theiner, Sarah
    Bolea-Fernandez, Eduardo
    Vanhaecke, Frank
    Koellensperger, Gunda
    NATURE REVIEWS METHODS PRIMERS, 2023, 3 (01):
  • [45] Inductively coupled plasma mass spectrometry
    Beauchemin, Diane
    ANALYTICAL CHEMISTRY, 2008, 80 (12) : 4455 - 4486
  • [46] Inductively coupled plasma mass spectrometry
    Thibaut Van Acker
    Sarah Theiner
    Eduardo Bolea-Fernandez
    Frank Vanhaecke
    Gunda Koellensperger
    Nature Reviews Methods Primers, 3
  • [47] Inductively coupled plasma mass spectrometry
    Beauchemin, D
    ANALYTICAL CHEMISTRY, 2002, 74 (12) : 2873 - 2893
  • [48] Inductively coupled plasma mass spectrometry
    Jakubowski, Norbert
    Horsky, Monika
    Roos, Peter H.
    Vanhaecke, Frank
    Prohaska, Thomas
    New Developments in Mass Spectrometry, 2015, 2015-January (03): : 208 - 318
  • [49] Inductively coupled plasma mass spectrometry
    Nature Reviews Methods Primers, 3 (1):
  • [50] Inductively Coupled Plasma Mass Spectrometry
    Beauchemin, Diane
    ANALYTICAL CHEMISTRY, 2010, 82 (12) : 4786 - 4810