A γ probe for radionuclide diagnostics of cancer

被引:2
|
作者
Bolozdynya, A. I. [1 ]
Vorobiev, K. A. [1 ]
Evgrafova, E. I. [1 ]
Zhukov, K. I. [2 ]
Kantserov, V. A. [1 ]
Sosnovtsev, V. V. [1 ]
Filipov, D. E.
Yagnyukova, A. K. [1 ]
机构
[1] Natl Res Nucl Univ, Moscow Engn Phys Inst, Moscow 115409, Russia
[2] Russian Acad Sci, Lebedev Phys Inst, Moscow 119991, Russia
关键词
Counting Rate; Positron Emission Tomograph; Moscow Engineer Physics Institute; Detector Axis; Silicon Photomultiplier;
D O I
10.1134/S0020441215010157
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A miniature gamma probe for nuclear medicine based on a LaBr3:Ce scintillation crystal and a silicon photomultiplier is described. The gamma ray detection efficiency is 29% for Cs-137 (662 keV) and 70% for Co-57 (122 keV). The spatial resolution and selectivity measured with a tungsten collimator for Co-57 are 8 mm and 26A degrees, respectively.
引用
收藏
页码:153 / 157
页数:5
相关论文
共 50 条
  • [11] RADIONUCLIDE OF CHOICE FOR USE WITH AN INTRAOPERATIVE PROBE
    THURSTON, MO
    KAEHR, JW
    MARTIN, EW
    MARTIN, EW
    ANTIBODY IMMUNOCONJUGATES AND RADIOPHARMACEUTICALS, 1991, 4 (04): : 595 - 601
  • [12] RADIONUCLIDE DIAGNOSTICS IN ST.PETERSBURG, RUSSIA
    Zvonova, Irina
    MEDICAL PHYSICS IN THE BALTIC STATES, 2011, : 147 - 148
  • [13] A limiting factor for the progress of radionuclide-based cancer diagnostics and therapy - Availability of suitable radionuclides
    Tolmachev, V
    Carlsson, R
    Lundqvist, H
    ACTA ONCOLOGICA, 2004, 43 (03) : 264 - 275
  • [14] Probe diagnostics of meteotron flame
    Kuznetsov, AA
    COMBUSTION EXPLOSION AND SHOCK WAVES, 2003, 39 (03) : 275 - 284
  • [15] Probe Diagnostics of a Rotating Plasma
    N. M. Gorshunov
    E. P. Potanin
    Instruments and Experimental Techniques, 2018, 61 : 543 - 547
  • [16] KSTAR edge probe diagnostics
    Bak, JG
    Lee, SG
    KSTAR Project Team
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (03): : 1578 - 1582
  • [17] Electrical Probe Diagnostics for KSTAR
    Bak, J. G.
    Lee, S. G.
    Kim, J. Y.
    CONTRIBUTIONS TO PLASMA PHYSICS, 2010, 50 (09) : 892 - 897
  • [18] DEVICE FOR PLASMA PROBE DIAGNOSTICS
    TIKHOMIROV, IA
    TIKHOMIROV, VV
    SHISHKOVSKII, VI
    SHKURKIN, VV
    HIGH TEMPERATURE, 1976, 14 (02) : 388 - 389
  • [19] Probe Diagnostics of Dusty Plasma
    A. V. Kashevarov
    High Temperature, 2002, 40 : 648 - 651
  • [20] Probe diagnostics for fusion devices
    Van Oost, G
    FUSION SCIENCE AND TECHNOLOGY, 2006, 49 (2T) : 357 - 366