Laboratory Evaluation of the Dual-Probe Heat-Pulse Method for Measuring Soil Water Content

被引:73
|
作者
Basinger, J. M. [2 ]
Kluitenberg, G. J. [1 ]
Ham, J. M. [1 ]
Frank, J. M. [3 ]
Barnes, P. L. [4 ]
Kirkham, M. B. [1 ]
机构
[1] Kansas State Univ, Dept Agron, Manhattan, KS 66505 USA
[2] Texas Tech Univ, Dept Plant & Soil Sci, Lubbock, TX 79409 USA
[3] US Forest Serv, Rocky Mt Res Stn, Ft Collins, CO 80526 USA
[4] Kansas State Univ, Dept Biol & Agr Engn, Manhattan, KS 66505 USA
关键词
D O I
10.2113/2.3.389
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The dual-probe heat-pulse (DPHP) method provides a means of estimating volumetric soil water content (theta) and change in volumetric water content (Delta theta) from measurements of volumetric heat capacity. The purpose of this investigation was to characterize the accuracy and precision that can be achieved in measuring theta and Delta theta with the DPHP method. Tempe pressure cells fitted with DPHP sensors were used to conduct desorption experiments in which DPHP-based estimates of theta and Delta theta were compared with values estimated by the gravimetric method. For water contents corresponding to soil water pressure potentials below -100 kPa, comparisons were made by packing the pressure cells with soil wetted to known water contents. The investigation was conducted with seven soil materials representing a wide range of physical properties for mineral soils. The DPHP sensors slightly overestimated theta at low water contents, but it was shown that the bias could be removed by using an empirical calibration equation, Delta theta 1.09 theta(DPHP) - 0.045. This relationship appears to be general inasmuch as it was shown to be applicable for all seven soil materials and for water contents ranging from 0.02 to 0.59 m(3) m(-3). The general calibration equation was also shown to be effective in removing bias in Delta theta estimates. Pooled regression analysis (all soil materials) showed that theta can be measured with a root mean square error (RMSE) of 0.022 m(3) m(-3). Greater precision can be achieved with Delta theta measurements (RMSE = 0.012 m(3) m(-3)); however, the results indicated a decrease in precision with increasing magnitude of Delta theta.
引用
收藏
页码:389 / 399
页数:11
相关论文
共 50 条
  • [21] Correcting dual-probe heat-pulse readings for changes in ambient temperature
    Young, M. H.
    Campbell, G. S.
    Yin, J.
    VADOSE ZONE JOURNAL, 2008, 7 (01): : 22 - 30
  • [22] Effect of Probe Deflection on Dual-Probe Heat-Pulse Thermal Conductivity Measurements
    Kluitenberg, Gerard J.
    Kamai, Tamir
    Vrugt, Jasper A.
    Hopmans, Jan W.
    SOIL SCIENCE SOCIETY OF AMERICA JOURNAL, 2010, 74 (05) : 1537 - 1540
  • [23] Integral form of the cylindrical perfect conductors solution for the dual-probe heat-pulse method
    Kluitenberg, Gerard J.
    Knight, John H.
    Kamai, Tamir
    SOIL SCIENCE SOCIETY OF AMERICA JOURNAL, 2021, 85 (06) : 1963 - 1969
  • [24] Test of a dual-probe, heat-pulse method for determining thermal properties of porous materials
    Bilskie, JR
    Horton, R
    Bristow, KL
    SOIL SCIENCE, 1998, 163 (05) : 346 - 355
  • [25] Semianalytical Solution for Dual-Probe Heat-Pulse Applications that Accounts for Probe Radius and Heat Capacity
    Knight, John H.
    Kluitenberg, Gerard J.
    Kamai, Tamir
    Hopmans, Jan W.
    VADOSE ZONE JOURNAL, 2012, 11 (02):
  • [26] PROBE FOR MEASURING SOIL SPECIFIC-HEAT USING A HEAT-PULSE METHOD
    CAMPBELL, GS
    CALISSENDORFF, C
    WILLIAMS, JH
    SOIL SCIENCE SOCIETY OF AMERICA JOURNAL, 1991, 55 (01) : 291 - 293
  • [27] Measuring soil water content in surface layer with heat-pulse technique
    Zhang, Xiao
    Wang, Yueyue
    Ren, Tusheng
    Nongye Gongcheng Xuebao/Transactions of the Chinese Society of Agricultural Engineering, 2015, 31 (02): : 72 - 78
  • [28] Measuring peat moisture content using the dual-probe heat pulse technique
    Campbell, DI
    Laybourne, CE
    Blair, IJ
    AUSTRALIAN JOURNAL OF SOIL RESEARCH, 2002, 40 (01): : 177 - 190
  • [29] Evaluation of microlysimeters used in turfgrass evapotranspiration studies using the dual-probe heat-pulse technique
    Bremer, DJ
    AGRONOMY JOURNAL, 2003, 95 (06) : 1625 - 1632
  • [30] Measuring Subsurface Soil-Water Evaporation with an Improved Heat-Pulse Probe
    Xiao, Zhang
    Lu, Sen
    Heitman, Joshua
    Horton, Robert
    Ren, Tusheng
    SOIL SCIENCE SOCIETY OF AMERICA JOURNAL, 2012, 76 (03) : 876 - 879