Thermoluminescent response of LiF: Mg,Cu,P+PTFE prepared in Mexico to 90Sr/90Y beta particles

被引:9
|
作者
González, PR
Azorín, J
机构
[1] Univ Autonoma Metropolitana Iztapalapa, Dept Fis, Mexico City 09340, DF, Mexico
[2] Inst Nacl Invest Nucl, Salazar 52045, Mexico, Mexico
[3] IPN, Ctr Invest Ciencia Aplicada & Tecnol Avanzada, Mexico City 11500, DF, Mexico
关键词
thermoluminescence LiF : Mg; Cu; P; beta particles;
D O I
10.1016/S0969-806X(01)00287-0
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Results of study of the thermoluminescent response of LiF:Mg,Cu,P+PTFE irradiated with beta particles are presented and compared with results for LiF TLD-100. Both materials exhibited a linear dose response in the range from 4.35 mGy to 2.17519 Gy. The glow curve of LiF: Mg,Cu,P+ PTFE exhibited four peaks while TLD-100 showed six. All the peaks studied for the two materials exhibited first order kinetics. The average values of activation energy were: 1.35, 1.58 and 2.51 eV for LiF: Mg,Cu,P+PTFE; and, 2.04, 2.24, 2.51 and 2.89 eV for LiF TLD-100. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:425 / 427
页数:3
相关论文
共 43 条
  • [21] Effects of very low dose-rate 90Sr/90Y exposure on the acute moist desquamation response of pig skin
    Millar, W. T.
    Hopewell, J. W.
    RADIOTHERAPY AND ONCOLOGY, 2007, 83 (02) : 187 - 195
  • [22] Simultaneous 137Cs and 90Sr/90Y detection in water on an LS counter: A quick response in a case of radiation emergency
    Stojkovic, Ivana
    Todorovic, Natasa
    Nikolov, Jovana
    Papovic, Snezana
    Gadzuric, Slobodan
    Vranes, Milan
    RADIATION PHYSICS AND CHEMISTRY, 2024, 221
  • [23] COMPARISON OF HP(0.07, 0°) FOR 90SR/90Y BETA RADIATION WITH CAF2:DY TLD-200 DOSIMETERS
    Alvarez Romero, Jose T.
    Tamayo Garcia, Jose A.
    RADIATION PROTECTION DOSIMETRY, 2017, 174 (01) : 53 - 61
  • [24] Effect of complexing anions on sorption of U(VI), 90Sr, and 90Y from aqueous solutions on layered double hydroxides of Mg, Al, and Nd
    Kulyukhin S.A.
    Krasavina E.P.
    Rumer I.A.
    Mizina L.V.
    Konovalova N.A.
    Gredina I.V.
    Radiochemistry, 2011, 53 (5) : 504 - 509
  • [25] Simulation of a 32P sourcewire and a 90Sr/90Y sourcetrain using MCNP4b and EGS4
    Todorovic, M
    Cremers, F
    Albers, D
    Schmidt, R
    ADVANCED MONTE CARLO FOR RADIATION PHYSICS, PARTICLE TRANSPORT SIMULATION AND APPLICATIONS, 2001, : 523 - 527
  • [26] Monte Carlo calculation of LiF:Mg,Cu,P thermoluminescent dosimeter correction factors for 18 F, 131I and 90 Y submersion dosimetry
    Ezzati, Ahad Ollah
    Mohajeri, Farzane
    Studenski, Matthew
    RADIATION MEASUREMENTS, 2025, 180
  • [27] The effects of non-centred catheter and guidewire on the dose distribution around source in catheter-based intravascular brachytherapy with 90Sr/90Y beta source
    Demir, B
    Demir, M
    Ahmed, AS
    RADIATION MEASUREMENTS, 2006, 41 (03) : 317 - 322
  • [28] Use of Layered Double Oxides and Hydroxides of Mg and Al for Removing Dyes from Aqueous Solutions Containing 137Cs, 90Sr, 90Y, and U(VI)
    S. A. Kulyukhin
    E. P. Krasavina
    I. A. Rumer
    A. V. Gordeev
    Radiochemistry, 2019, 61 : 585 - 591
  • [29] Use of Layered Double Oxides and Hydroxides of Mg and Al for Removing Dyes from Aqueous Solutions Containing 137Cs, 90Sr, 90Y, and U(VI)
    Kulyukhin, S. A.
    Krasavina, E. P.
    Rumer, I. A.
    Gordeev, A. V.
    RADIOCHEMISTRY, 2019, 61 (05) : 585 - 591
  • [30] DEPTH-DOSE CURVES OF THE BETA REFERENCE FIELDS 147Pm, 85Kr AND 90Sr/90Y PRODUCED BY THE BETA SECONDARY STANDARD BSS2
    Brunzendorf, Jens
    RADIATION PROTECTION DOSIMETRY, 2012, 151 (02) : 211 - 217