Improvement Method of Fast and Isocratic RP-HPLC Analysis of Major Diterpene Glycoside from Stevia rebaudiana Leaves

被引:7
|
作者
Martono, Yohanes [1 ,2 ]
Riyanto, Sugeng [1 ]
Rohman, Abdul [1 ]
Martono, Sudibyo [1 ]
机构
[1] Gadjah Mada Univ, Fac Pharm, Yogyakarta 55221, Indonesia
[2] SatyaWacana Christian Univ, Dept Chem, Salatiga 50733, Indonesia
关键词
LIQUID-CHROMATOGRAPHY; PLANT-MATERIAL; STEVIOSIDE; REBAUDIOSIDE; QUANTIFICATION; SWEETENER;
D O I
10.1063/1.4958509
中图分类号
O59 [应用物理学];
学科分类号
摘要
Stevioside and rebaudioside A are major diterpene glycoside from Stevia rebaudiana. These compounds have similar structure and make both compounds have close polarity. The aim of this study was to improve isocratic RP-HPLC analysis to achieve a complete separation of stevioside and rebaudioside A in baseline peak. The method improved was conducted on Eurosphere C-18 (250 x 4.6 mm, 5 mu m) as the stationary phase. Mobile phase was made by a mixture of water-methanol (90: 10, v / v, pH = 3.0); acetonitrile, and trifluoroacetic acid (TFA) in the ratio 65: 35: 0.01 (v/v/v). Flow rate of mobile phase was 0.6 mL/min. The detection was performed in UV-210 nm. The improved method has complete separation by R > 2.00 in baseline peak. The linearity of the standard curve was obtained with a correlation coefficient of 0.9998 for rebaudioside A and 0.9994 for stevioside. The percent recovery was determined by standard addition method with a mean recovery of 100.82% for rebaudioside A and 101.04% for stevioside. The relative standard deviation (RSD) of intraday precision varies from 0.34 - 1.79% for rebaudioside A and 0.31 - 1.81% for stevioside, and interday precision showed RSD 1.47% for rebaudioside A and 0.37% for stevioside. While the sensitivity reported in the limit of detection (LOD) value of method improvement was 1.00 mu g/mL for both rebaudioside A and stevioside. The limit of quantitation (LOQ) of the method was 3.00 mu g/mL for both respected compounds. The small changes of the mobile phase composition, the mobile phase is reused after 1 week, flow rate, and column temperature did not alter the method performance significantly. The reliable and robust of the developed and validated method was applied to both simple and complex matrices of samples including S. rebaudiana leaves for major diterpene glycoside analysis.
引用
收藏
页数:8
相关论文
共 36 条
  • [31] Determining Seasonal Changes in Three Major Phenolic Compounds from Bark of Saraca asoca in Comparison with Local Market Sample Using RP-HPLC Analysis
    Ketkar, Pushkar M.
    Nayak, Shraddha U.
    Pai, Sandeep R.
    Joshi, Rajesh K.
    NATIONAL ACADEMY SCIENCE LETTERS-INDIA, 2015, 38 (05): : 403 - 407
  • [32] Development of Method for Isolation of Selected Group of Pesticides from Soil by Solid Sample Flow-Throught Extraction before RP-HPLC Analysis
    Chalanyova, Maria
    Prochazkova, Ivana
    Hutta, Milan
    CHEMICKE LISTY, 2013, 107 (02): : 165 - 171
  • [33] Development of a Novel, Fast, Simple, Non-derived RP-HPLC Method for simultaneous Estimation of Benzocaine and Tibezonium Iodide from Mucoadhesive Dosage Form as well as Human Saliva and its Validation
    Syed, Muhammad Ali
    Khan, Ikram Ullah
    Iqbal, Muhammad Shahid
    Syed, Haroon Khalid
    Irfan, Muhammad
    LATIN AMERICAN JOURNAL OF PHARMACY, 2021, 40 (06): : 1281 - 1287
  • [34] A new green approach for the reduction of consumed solvents and simultaneous quality control analysis of several pharmaceuticals using a fast and economic RP-HPLC method; a case study for a mixture of piracetam, ketoprofen and omeprazole drugs
    Abdelgawad, Mohamed A.
    Abdelaleem, Eglal A.
    Gamal, Mohammed
    Abourehab, Mohammed A. S.
    Abdelhamid, Nessreen S.
    RSC ADVANCES, 2022, 12 (25) : 16301 - 16309
  • [35] Development and validation of novel RP-HPLC method for midostaurin determination using analytical quality by design approach from regulatory perspective and determination of major degradation compounds of midostaurin using LC-MS
    Saddala, Madhu Prakash Reddy
    Konduru, Naresh
    Gundla, Rambabu
    Kowtharapu, Leela Prasad
    BIOMEDICAL CHROMATOGRAPHY, 2022, 36 (12)
  • [36] Fast and Environmentally Friendly Quantitative Analysis of Active Agents in Anti-Diabetic Tablets by an Alternative Laser-Induced Breakdown Spectroscopy (LIBS) Method and Comparison to a Validated Reversed-Phase High-Performance Liquid Chromatography (RP-HPLC) Method
    Ulises Contreras, Victor
    Meneses-Nava, Marco A.
    Ornelas-Soto, Nancy
    Barbosa-Garcia, Oracio
    Lopez-de-Alba, Pedro L.
    Maldonado, Jose L.
    Ramos-Ortiz, Gabriel
    Acevedo-Aguilar, Francisco J.
    Lopez-Martinez, Leticia