Improvement Method of Fast and Isocratic RP-HPLC Analysis of Major Diterpene Glycoside from Stevia rebaudiana Leaves

被引:7
|
作者
Martono, Yohanes [1 ,2 ]
Riyanto, Sugeng [1 ]
Rohman, Abdul [1 ]
Martono, Sudibyo [1 ]
机构
[1] Gadjah Mada Univ, Fac Pharm, Yogyakarta 55221, Indonesia
[2] SatyaWacana Christian Univ, Dept Chem, Salatiga 50733, Indonesia
关键词
LIQUID-CHROMATOGRAPHY; PLANT-MATERIAL; STEVIOSIDE; REBAUDIOSIDE; QUANTIFICATION; SWEETENER;
D O I
10.1063/1.4958509
中图分类号
O59 [应用物理学];
学科分类号
摘要
Stevioside and rebaudioside A are major diterpene glycoside from Stevia rebaudiana. These compounds have similar structure and make both compounds have close polarity. The aim of this study was to improve isocratic RP-HPLC analysis to achieve a complete separation of stevioside and rebaudioside A in baseline peak. The method improved was conducted on Eurosphere C-18 (250 x 4.6 mm, 5 mu m) as the stationary phase. Mobile phase was made by a mixture of water-methanol (90: 10, v / v, pH = 3.0); acetonitrile, and trifluoroacetic acid (TFA) in the ratio 65: 35: 0.01 (v/v/v). Flow rate of mobile phase was 0.6 mL/min. The detection was performed in UV-210 nm. The improved method has complete separation by R > 2.00 in baseline peak. The linearity of the standard curve was obtained with a correlation coefficient of 0.9998 for rebaudioside A and 0.9994 for stevioside. The percent recovery was determined by standard addition method with a mean recovery of 100.82% for rebaudioside A and 101.04% for stevioside. The relative standard deviation (RSD) of intraday precision varies from 0.34 - 1.79% for rebaudioside A and 0.31 - 1.81% for stevioside, and interday precision showed RSD 1.47% for rebaudioside A and 0.37% for stevioside. While the sensitivity reported in the limit of detection (LOD) value of method improvement was 1.00 mu g/mL for both rebaudioside A and stevioside. The limit of quantitation (LOQ) of the method was 3.00 mu g/mL for both respected compounds. The small changes of the mobile phase composition, the mobile phase is reused after 1 week, flow rate, and column temperature did not alter the method performance significantly. The reliable and robust of the developed and validated method was applied to both simple and complex matrices of samples including S. rebaudiana leaves for major diterpene glycoside analysis.
引用
收藏
页数:8
相关论文
共 36 条
  • [1] Fast and isocratic HPLC-method for steviol glycosides analysis from Stevia rebaudiana leaves
    Dominik Bergs
    Bernhard Burghoff
    Matthias Joehnck
    Georg Martin
    Gerhard Schembecker
    Journal für Verbraucherschutz und Lebensmittelsicherheit, 2012, 7 : 147 - 154
  • [2] Fast and isocratic HPLC-method for steviol glycosides analysis from Stevia rebaudiana leaves
    Bergs, Dominik
    Burghoff, Bernhard
    Joehnck, Matthias
    Martin, Georg
    Schembecker, Gerhard
    JOURNAL FUR VERBRAUCHERSCHUTZ UND LEBENSMITTELSICHERHEIT-JOURNAL OF CONSUMER PROTECTION AND FOOD SAFETY, 2012, 7 (02): : 147 - 154
  • [3] A Validated RP-HPLC Method for Quantification of Steviol Glycoside: Rebaudioside A in Extracts of Stevia Rebaudiana Leaf
    Kolate, Nikhil S.
    Mishra, Himanshu
    Kini, Suvarna G.
    Raghavan, Govindarajan
    Vyas, Tejas B.
    CHROMATOGRAPHIA, 2021, 84 (01) : 21 - 26
  • [4] A Validated RP-HPLC Method for Quantification of Steviol Glycoside: Rebaudioside A in Extracts of Stevia Rebaudiana Leaf
    Nikhil S. Kolate
    Himanshu Mishra
    Suvarna G. Kini
    Govindarajan Raghavan
    Tejas B. Vyas
    Chromatographia, 2021, 84 : 21 - 26
  • [5] Analysis of sweet diterpene glycosides from Stevia rebaudiana:: Improved HPLC method
    Kolb, N
    Herrera, JL
    Ferreyra, DJ
    Uliana, RF
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2001, 49 (10) : 4538 - 4541
  • [6] Improved HPLC method for the evaluation of the major steviol glycosides in leaves of Stevia rebaudiana
    Woelwer-Rieck, Ursula
    Lankes, Christa
    Wawrzun, Andreas
    Wuest, Matthias
    EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2010, 231 (04) : 581 - 588
  • [7] Improved HPLC method for the evaluation of the major steviol glycosides in leaves of Stevia rebaudiana
    Ursula Woelwer-Rieck
    Christa Lankes
    Andreas Wawrzun
    Matthias Wüst
    European Food Research and Technology, 2010, 231 : 581 - 588
  • [8] Analysis Study of Stevioside and Rebaudioside A from Stevia rebaudiana Bertoni by Normal Phase SPE and RP-HPLC
    Martono, Y.
    Rohman, A.
    Riyanto, S.
    Martono, S.
    12TH JOINT CONFERENCE ON CHEMISTRY, 2018, 349
  • [9] Comparative study of HPLC methods for the Analysis of Diterpene Glycosides from Stevia rebaudiana
    Hoekstra, B.
    Traub, J.
    Chamberlain, K.
    Baugh, S.
    Venkataraman, S. K.
    PLANTA MEDICA, 2009, 75 (09) : 1003 - 1003
  • [10] Fast methodology of analysing major steviol glycosides from Stevia rebaudiana leaves
    Lorenzo, Candida
    Serrano-Diaz, Jessica
    Plaza, Miguel
    Quintanilla, Carmen
    Alonso, Gonzalo L.
    FOOD CHEMISTRY, 2014, 157 : 518 - 523