Bone vibration measurement using ultrasound: Application to detection of hip prosthesis loosening

被引:41
|
作者
Rowlands, A.
Duck, F. A.
Cunningham, J. L. [1 ]
机构
[1] Univ Bath, Dept Mech Engn, Bath BA2 7AY, Avon, England
关键词
hip prosthesis; loosening; vibration; ultrasound; detection;
D O I
10.1016/j.medengphy.2007.04.017
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Hip prosthesis loosening can be determined in vivo using a vibration-based technique called vibrometry. In this technique, a low frequency (<1000 Hz) sinusoidal vibration is applied to the femoral condyles and the resulting vibration is measured at the greater trochanter. If the prosthesis is securely fixed, the output vibration signal matches that of the input vibration, whereas if the prosthesis is loose, the output vibration signal is distorted and shows the marked presence of harmonics of the input frequency. One of the main problems with this application of this technique is in measuring the output vibration where significant amounts of soft tissue cover the measurement site. In order to circumvent this problem, an ultrasound probe, normally used for the measurement of blood flow, has been used to measure the output vibration. This has been evaluated by comparing the results obtained from the ultrasound probe with those from a conventional accelerometer in models representing a tight and loose hip prosthesis under simulated clinical conditions. The ultrasound probe was able to consistently detect the output vibration, for both the loose and secure prostheses. Under the test conditions used (which attempted to simulate a large thickness of soft tissue), the ultrasound probe was able to produce a greatly enhanced output vibration signal compared to the accelerometer. This suggests that the use of an ultrasound probe to detect mechanically induced vibration through significant amounts of soft tissue appears to be viable and could lead to enhanced detection of prosthesis loosening using this technique. (C) 2007 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:278 / 284
页数:7
相关论文
共 50 条
  • [41] Material Removal of Hip Stem Prosthesis Using Bio-Inspiration from Trabecular Bone
    Bilhere-Dieuzeide, Mathieu
    Chaves-Jacob, Julien
    Buhon, Emmanuel
    Biguet-Mermet, Guillaume
    Linares, Jean -Marc
    V CIRP CONFERENCE ON BIOMANUFACTURING, 2022, 110 : 267 - 272
  • [42] Modeling and Detection of Joint Loosening using Output-Only Broad-Band Vibration Data
    Milanese, A.
    Marzocca, P.
    Nichols, J. M.
    Seaver, M.
    Trickey, S. T.
    STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2008, 7 (04): : 309 - 328
  • [43] Vibration-Based Loosening Detection of a Multi-Bolt Structure Using Machine Learning Algorithms
    Eraliev, Oybek
    Lee, Kwang-Hee
    Lee, Chul-Hee
    SENSORS, 2022, 22 (03)
  • [44] Application of ultrasound-tagged photons for measurement of amplitude of vibration of tissue caused by ultrasound: theory, simulation, and experiments
    Devi, C. Usha
    Vasu, R. M.
    Sood, A. K.
    JOURNAL OF BIOMEDICAL OPTICS, 2006, 11 (03)
  • [45] Tissue vibration pulsatility for arterial bleeding detection using Doppler ultrasound
    Xie, Zhiyong
    Kim, Eung-Hun
    Kim, Yongmin
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 2272 - 2275
  • [46] Combined bone scintigraphy with 99mTc-MDP and 99mTc-ciprofloxacin in differentiation of hip and knee prosthesis aseptic loosening and infection: A preliminary study
    Pucar, Dragan
    Jankovic, Zoran
    Bascarevic, Zoran
    Starcevic, Srdjan
    Cizmic, Milica
    Radulovic, Marija
    Sisic, Marija
    Dugonjic, Sanja
    Jaukovic, Ljiljana
    Ajdinovic, Boris
    VOJNOSANITETSKI PREGLED, 2017, 74 (07) : 666 - 671
  • [47] EARLY DETECTION OF PROSTHETIC-HIP LOOSENING - COMPARISON OF LOW-VISCOSITY AND HIGH-VISCOSITY BONE-CEMENT
    MJOBERG, B
    FRANZEN, H
    SELVIK, G
    ACTA ORTHOPAEDICA SCANDINAVICA, 1990, 61 (03): : 273 - 274
  • [48] Application of an Improved Ultrasound Full-Waveform Inversion in Bone Quantitative Measurement
    Suo, Meng
    Zhang, Dong
    Yang, Yan
    SYMMETRY-BASEL, 2021, 13 (02): : 1 - 29
  • [49] The reconstruction of extended acetabular bone defects in revision hip arthroplasty - Risk factors for migration and loosening using the pedestal cup
    Tohtz, S.
    Katterle, H.
    Matziolis, G.
    Drahn, T.
    Perka, C.
    ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2007, 145 (02): : 176 - 180
  • [50] Cemented acetabular revision of aseptic cemented hip arthroplasties loosening using a superior structural bone graft and a Muller ring
    Massin, P
    Tanaka, C
    Huten, D
    Duparc, J
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 1998, 84 (01): : 51 - 60