Bone vibration measurement using ultrasound: Application to detection of hip prosthesis loosening

被引:41
|
作者
Rowlands, A.
Duck, F. A.
Cunningham, J. L. [1 ]
机构
[1] Univ Bath, Dept Mech Engn, Bath BA2 7AY, Avon, England
关键词
hip prosthesis; loosening; vibration; ultrasound; detection;
D O I
10.1016/j.medengphy.2007.04.017
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Hip prosthesis loosening can be determined in vivo using a vibration-based technique called vibrometry. In this technique, a low frequency (<1000 Hz) sinusoidal vibration is applied to the femoral condyles and the resulting vibration is measured at the greater trochanter. If the prosthesis is securely fixed, the output vibration signal matches that of the input vibration, whereas if the prosthesis is loose, the output vibration signal is distorted and shows the marked presence of harmonics of the input frequency. One of the main problems with this application of this technique is in measuring the output vibration where significant amounts of soft tissue cover the measurement site. In order to circumvent this problem, an ultrasound probe, normally used for the measurement of blood flow, has been used to measure the output vibration. This has been evaluated by comparing the results obtained from the ultrasound probe with those from a conventional accelerometer in models representing a tight and loose hip prosthesis under simulated clinical conditions. The ultrasound probe was able to consistently detect the output vibration, for both the loose and secure prostheses. Under the test conditions used (which attempted to simulate a large thickness of soft tissue), the ultrasound probe was able to produce a greatly enhanced output vibration signal compared to the accelerometer. This suggests that the use of an ultrasound probe to detect mechanically induced vibration through significant amounts of soft tissue appears to be viable and could lead to enhanced detection of prosthesis loosening using this technique. (C) 2007 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:278 / 284
页数:7
相关论文
共 50 条
  • [1] A Medical Wireless Measurement System for Hip Prosthesis Loosening Detection Based on Vibration Analysis
    Institute of Semiconductors and Microsystems, Technische Universität Dresden, Dresden, Germany
    不详
    不详
    不详
    Sensors Transducers, 2013, SPEC.ISS.1 (134-144):
  • [2] A telemetry system for the detection of hip prosthesis loosening by vibration analysis
    Puers, R
    Catrysse, M
    Vandevoorde, G
    Collier, RJ
    Louridas, E
    Burny, F
    Donkerwolcke, M
    Moulart, F
    SENSORS AND ACTUATORS A-PHYSICAL, 2000, 85 (1-3) : 42 - 47
  • [3] Excitation and Wireless Lock-in Measurement of Hip Prosthesis Vibrations for Loosening Detection
    Marschner, Uwe
    Fischer, Wolf-Joachim
    Jettkant, Birger
    Ruwisch, Dietmar
    Graetz, Hagen
    Woldt, Gregor
    Clasbrummel, Bernhard
    TM-TECHNISCHES MESSEN, 2010, 77 (02) : 74 - 82
  • [4] Integration of a wireless lock-in measurement of hip prosthesis vibrations for loosening detection
    Marschner, U.
    Graetz, H.
    Jettkant, B.
    Ruwisch, D.
    Woldt, G.
    Fischer, W. -J.
    Clasbrummel, B.
    SENSORS AND ACTUATORS A-PHYSICAL, 2009, 156 (01) : 145 - 154
  • [5] Vibration analysis in the detection of total hip prosthetic loosening
    Li, PLS
    Jones, NB
    Gregg, PJ
    MEDICAL ENGINEERING & PHYSICS, 1996, 18 (07) : 596 - 600
  • [6] Accurate diagnosis of hip prosthesis loosening using a vibrational technique
    Georgiou, AP
    Cunningham, JL
    CLINICAL BIOMECHANICS, 2001, 16 (04) : 315 - 323
  • [7] Model-based Monitoring of Hip Prosthesis Vibrations for Loosening Detection
    Marschner, Uwe
    Sauer, Sebastian
    Koerbitz, Rene
    Starke, Eric
    Fischer, Wolf-Joachim
    Clasbrummel, Bernhard
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2014, 59 : S987 - S988
  • [8] Gruen zones:: A tool for bone scan evaluation in suspected hip prosthesis loosening?
    Huber, H
    Griessler, W
    Maschek, W
    Hatzl-Griesenhofer, M
    Böhler, N
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1999, 26 (09): : 1054 - 1054
  • [9] AUTOCLAVED CANCELLOUS BONE-GRAFTING FOLLOWING LOOSENING OF A TOTAL HIP-PROSTHESIS
    WAGNER, M
    PESCH, HJ
    ORTHOPADE, 1989, 18 (05): : 463 - 467
  • [10] RADIONUCLIDE BONE IMAGING AS A MEANS OF DIFFERENTIATING LOOSENING AND INFECTION IN PATIENTS WITH A PAINFUL TOTAL HIP-PROSTHESIS
    WILLIAMSON, BRJ
    MCLAUGHLIN, RE
    WANG, GJ
    MILLER, CW
    TEATES, CD
    BRAY, ST
    RADIOLOGY, 1979, 133 (03) : 723 - 726