A New Fast Method of Magnetometer Calibration Based on Hexahedron Measurement

被引:0
|
作者
Hua, Yongzhu [1 ]
Qin, Huibin [1 ]
Luo, Bowen [2 ]
Wu, Jianfeng [1 ]
机构
[1] Hangzhou Dianzi Univ, Sch Elect & Informat, Hangzhou 310018, Zhejiang, Peoples R China
[2] Ningbo Jiangbei Yongjiang Elect Instrument Plast, Ningbo 315000, Zhejiang, Peoples R China
关键词
film resistance; thermal equilibrium equation; bernoulli equation; flow rate; wind pressure; schmidt compensation;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
According to the thermal equilibrium equation, the resistance value of the film is converted into the air flow rate, and the flow rate is converted into the wind pressure by the Bernoulli equation. The wind pressure is detected based on the film resistance. Using the digital filter to remove the collected anomaly data, combined with Schmidt compensation to remove the sensor detection process delay. Test surface based on the film resistance of the wind pressure detection system to detect the air flow and wind pressure, can be widely used in industrial, military.
引用
收藏
页码:35 / 40
页数:6
相关论文
共 50 条
  • [21] Horizontal Error Calibration Method for Triaxial Fluxgate Magnetometer
    Yan, Hui
    Xiao, Changhan
    Liu, Shengdao
    Zhang, Zhaoyang
    2008 WORLD AUTOMATION CONGRESS PROCEEDINGS, VOLS 1-3, 2008, : 1407 - 1411
  • [22] Magnetometer calibration algorithm based on ellipsoid constraint
    董明杰
    Chou Wusheng
    Fang Bin
    High Technology Letters, 2015, 21 (04) : 407 - 413
  • [23] Calibration of a Vector Magnetometer Based on Minimum Residual
    Zlygostev, I. N.
    Morozov, Yu. V.
    Murasev, A. A.
    Spektor, A. A.
    OPTOELECTRONICS INSTRUMENTATION AND DATA PROCESSING, 2024, 60 (06) : 803 - 809
  • [24] Magnetometer calibration algorithm based on ellipsoid constraint
    Dong, Mingjie
    Chou, Wusheng
    Fang, Bin
    High Technology Letters, 2015, 21 (04) : 407 - 413
  • [25] Fast Amplitude-Only Measurement Method for Phased Array Calibration
    Long, Rui
    Ouyang, Jun
    Yang, Feng
    Han, Wangwang
    Zhou, Longjian
    IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 2017, 65 (04) : 1815 - 1822
  • [26] Fast method of eliminating extraneous in near filed measurement of calibration load
    Yang, Shan
    Bai, Ming
    Miao, Jungang
    Beijing Hangkong Hangtian Daxue Xuebao/Journal of Beijing University of Aeronautics and Astronautics, 2010, 36 (02): : 235 - 238
  • [27] An efficient method for tri-axis magnetometer calibration
    Li, Jiakun
    Shu, Kuangi
    Zhang, Heng
    2019 IEEE SMARTWORLD, UBIQUITOUS INTELLIGENCE & COMPUTING, ADVANCED & TRUSTED COMPUTING, SCALABLE COMPUTING & COMMUNICATIONS, CLOUD & BIG DATA COMPUTING, INTERNET OF PEOPLE AND SMART CITY INNOVATION (SMARTWORLD/SCALCOM/UIC/ATC/CBDCOM/IOP/SCI 2019), 2019, : 654 - 660
  • [28] A fast three-dimensional measurement method based on color fringe projection and background intensity calibration
    Zhu, Qian
    Du, Hubing
    Tang, Bo
    Ma, Yueyang
    OPTICAL AND QUANTUM ELECTRONICS, 2024, 56 (07)
  • [29] A New Full Pose Measurement Method for Robot Calibration
    Hoai-Nhan Nguyen
    Zhou, Jian
    Kang, Hee-Jun
    SENSORS, 2013, 13 (07) : 9132 - 9147
  • [30] A novel multi-view three-dimensional visual measurement method based on hexahedron targets
    The Higher Educational Key Laboratory for Measuring and Control Technology and Instrumentations of Heilongjiang province, Harbin University of Science and Technology, Harbin, China
    Int. J. Multimedia Ubiquitous Eng., 9 (109-116):