Novel gadolinium poly(vinyl chloride) membrane sensor based on a new S-N Schiff's base

被引:99
|
作者
Ganjali, MR
Emami, M
Rezapour, M
Shamsipur, M
Maddah, B
Salavati-Niasari, M
Hosseini, M
Talebpoui, Z
机构
[1] Univ Tehran, Dept Chem, Tehran, Iran
[2] Razi Univ, Dept Chem, Kermanshah, Iran
[3] Kashan Univ, Dept Chem, Kashan, Iran
[4] Tarbiat Modares Univ, Dept Chem, Tehran, Iran
关键词
potentiometry; Gd(III) ion-selective electrode; PVC membrane; S-N Schiff's base;
D O I
10.1016/S0003-2670(03)00921-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, a novel gadolinium membrane sensor based on new S-N Schiff s base (2-[{3-[(2-sulfanylphenyl)imino)- 1-methylbutylidene}amino]phenyl hydrosulfide (SMPH) is presented. The sensor displays a linear dynamic range between 1.0 x 10(-1) and 1.0 x 10(-5) M, with a nice Nernstian slope of 19.8 +/- 0.3 mV per decade and a detection limit of 3.0 x 10(-6) M. The best performance was obtained with a membrane composition of 33% poly(vinyl chloride), 61% benzyl acetate, 2% sodium tetraphenyl borate and 5% SMPH. The potentiometric response of the sensor is independent of the pH of the solution in the pH range of 4.0-8.0. The sensor possesses the advantages of short conditioning time, very fast response time, and especially, very good selectivity towards a large number of cations, such as Sm(III), Ce(III), La(III), Cu(II), Pb(II) and Hg(II). The electrode can be used for at least 9 weeks without any considerable divergence in the potentials. It was used as an indicator electrode in potentiometric titration of Gd(III) ions with EDTA, and recovery of Gd(III) from various binary mixtures. The electrode was also applied to the determination of Gd(III) in a urine sample. (C) 2003 Published by Elsevier B.V.
引用
收藏
页码:51 / 59
页数:9
相关论文
共 50 条
  • [31] Highly Selective Ratiometric Fluorescent Sensor for La(III) Ion Based on a New Schiff's Base
    Hosseini, Morteza
    Ganjali, Mohammad Reza
    Veismohammadi, Bahareh
    Riahl, Siavash
    Norouzi, Parviz
    Salavati-Niasari, Masoud
    Abkenar, Shiva Dehghan
    ANALYTICAL LETTERS, 2009, 42 (07) : 1029 - 1040
  • [32] Highly Selective and Sensitive Tin(II) Membrane Electrode Based on a New Synthesized Schiff's Base
    Hosseini, Morteza
    Sadeghi, Hayedeh Bagheri
    Rahimi, Mohammad
    Salavati-Niasari, Masoud
    Abkenar, Shiva Dehghan
    Alizadeh, Kamal
    Ganjali, Mohammad Reza
    ELECTROANALYSIS, 2009, 21 (07) : 859 - 866
  • [33] Highly selective and sensitive chromium(III) membrane sensors based on a new tridentate Schiff's base
    Ganjali, Mohammad Reza
    Norouzi, P.
    Faridbod, F.
    Ghorbani, M.
    Adib, M.
    ANALYTICA CHIMICA ACTA, 2006, 569 (1-2) : 35 - 41
  • [34] Evaluation and Characteristics of a Tb3+ Electrochemical Sensor Based on Plasticized Poly(vinyl chloride) Membrane
    Zamani, Hassan Ali
    Sahebnasagh, Sara
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2013, 8 (03): : 3696 - 3707
  • [35] Novel copper(II)-selective membrane electrode based on a new synthesized Schiff base
    Akhond, Morteza
    Najafi, Mohammad Bagher
    Sharghi, Hashem
    Tashkhourian, Javad
    Naiemi, Hossein
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2007, 54 (02) : 331 - 337
  • [36] Evaluating two new synthesized S-N Schiff bases on the corrosion of copper in 15% hydrochloric acid
    Behpour, M.
    Ghoreishi, S. M.
    Salavati-Niasari, M.
    Ebrahimi, B.
    MATERIALS CHEMISTRY AND PHYSICS, 2008, 107 (01) : 153 - 157
  • [37] Novel biocidal N-halamine plastic based on poly(vinyl chloride): Preparation and characteristics
    Chylinska, Marta
    Kaczmarek, Halina
    Burkowska-But, Aleksandra
    Walczak, Maciej
    JOURNAL OF INDUSTRIAL AND ENGINEERING CHEMISTRY, 2015, 28 : 124 - 130
  • [38] Synthesis of a new octadentates Schiff's base and its application in construction of a highly selective and sensitive lanthanum (III) membrane sensor
    Ganjali, M. R.
    Gholivand, M. B.
    Rahimi-Nasrabadi, M.
    Maddah, B.
    Salavati-Niasari, M.
    Ahmadi, F.
    SENSOR LETTERS, 2006, 4 (04) : 356 - 363
  • [39] Synthesis and properties of two novel poly(Schiff base)s and their rare-earth complexes
    Yang, J
    Sun, WL
    Jiang, HJ
    Shen, ZQ
    POLYMER, 2005, 46 (23) : 10478 - 10483
  • [40] A modified selective optical sensor for selenium determination based on incorporating xylenol orange in a poly(vinyl chloride) membrane
    Hassan, Abeer M. E.
    Alshehri, Reem F.
    El-Bahy, Salah M.
    Amin, Alaa S.
    Aish, Mai
    RSC ADVANCES, 2023, 13 (49) : 34618 - 34629