Influence of correction of flow limitation on continuous positive airway pressure efficiency in sleep apnoea/hypopnoea syndrome

被引:63
|
作者
Meurice, JC
Paquereau, J
Denjean, A
Patte, F
Series, F
机构
[1] CHU Poitiers, Serv Pneumol, F-86000 Poitiers, France
[2] CHU Poitiers, Serv Explorat Fonctionnelles, Poitiers, France
[3] Univ Laval, Hop Laval, Unite Rech, Ctr Pneumol, Quebec City, PQ G1K 7P4, Canada
关键词
continuous positive airway pressure; flow limitation; sleep apnoea syndrome; treatment;
D O I
10.1183/09031936.98.11051121
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
We evaluated the efficiency of two different treatment procedures with continuous positive airway pressure (CPAP) on sleep, nocturnal breathing characteristics and daytime vigilance in 18 newly diagnosed patients with untreated sleep apnoea/hypopnoea syndrome (SAHS) randomly allocated to two different groups. In group T, the positive pressure (PP) level was set to suppress Bow limitation (PFL), while in group II the PP was set at a level that eliminated only apnoea/hypopnoea and snoring (PAHS). At the end of a 3 week period of home CPAP therapy, a follow-up sleep study, vigilance and cognitive tests were made. Overall, PFL was significantly higher than PAHS values (PFL: 10.4+/-2.6 cmH(2)O; PAHS: 8.9+/-2.6 cmH(2)O; p<0.01, mean+/-SD). We found no difference in sleep quality nocturnal saturation and apnoea/hypopnoea index, or in daytime vigilance tests be: tween the two groups at the end of the treatment period. However, there was a significantly greater scattering in the changes of sleep latency in group II than in group I. This was associated with a significant difference in the daily duration of nasal CPAP use between the two groups (group I: 7.29+/-0.95 h.day(-1);( )group II: 6.01+/-0.94 h.day(-1); p=0.01) and with a positive correlation between final maintenance of wakefulness test values and the duration of CPAP use (p<0.05; r=0.55). These results tend to show that correcting flow limitation is associated with a higher observance and a more important efficiency in normalizing daytime vigilance than with conventional nasal continuous positive airway pressure.
引用
收藏
页码:1121 / 1127
页数:7
相关论文
共 50 条
  • [41] Adherence to continuous positive airway pressure in women with obstructive sleep apnoea
    Nunez, Nuria Reyes
    Gonzalez-Martinez, Monica
    Sanchez-Armengol, Angeles
    Jurado-Gamez, Bernabe
    Cordero-Guevara, Jose
    Troncoso, Maria F.
    Abad-Fernandez, Araceli
    Teran-Santos, Joaquin
    Caballero-Rodriguez, Julian
    Martin-Romero, Mercedes
    Encabo-Motino, Ana
    Martinez-Garcia, Miguel A.
    Sacristan-Bou, Lirios
    Navarro-Esteva, Javier
    Somoza-Gonzalez, Maria
    Masa, Juan F.
    Sanchez-Quiroga, Maria A.
    Jara-Chinarro, Beatriz
    Orosa-Bertol, Belen
    Campos-Rodriguez, Francisco
    EUROPEAN RESPIRATORY JOURNAL, 2017, 50
  • [42] Nasal pressure recording in the diagnosis of sleep apnoea hypopnoea syndrome
    Sériès, F
    Marc, I
    THORAX, 1999, 54 (06) : 506 - 510
  • [43] Randomised controlled trial of variable-pressure versus fixed-pressure continuous positive airway pressure (CPAP) treatment for patients with obstructive sleep apnoea/hypopnoea syndrome (OSAHS)
    Vennelle, M.
    White, S.
    Riha, R. L.
    Mackay, T. W.
    Douglas, N. J.
    JOURNAL OF SLEEP RESEARCH, 2008, 17 : 145 - 146
  • [44] Cost-effectiveness of using continuous positive airways pressure in treating severe obstructive sleep apnoea/hypopnoea syndrome in the UK
    Guest, J. F.
    Helter, M. T.
    Morga, A.
    Stradling, J. R.
    JOURNAL OF SLEEP RESEARCH, 2008, 17 : 161 - 161
  • [45] EFFECTIVENESS OF CONTINUOUS POSITIVE AIRWAY PRESSURE ON BLOOD PRESSURE IN PATIENTS WITH OBSTRUCTIVE SLEEP APNOEA
    Zhao Qing
    Liu Zhihong
    Doug, Mcevoy
    Luo Qin
    Zhao Zhihui
    Zhang Hongliang
    Wang Yong
    HEART, 2010, 96 : A183 - A183
  • [46] Autonomic effects of short term nasal continuous positive airway pressure therapy in sleep apnoea syndrome
    Bilge, AR
    Lacroix, A
    Gerard, P
    Kulbertus, HE
    Poirrier, R
    Pierard, LA
    CIRCULATION, 1996, 94 (08) : 2159 - 2159
  • [47] FACTORS AFFECTING CONCORDANCE WITH CONTINUOUS POSITIVE AIRWAY PRESSURE (CPAP) IN OBSTRUCTIVE SLEEP APNOEA SYNDROME (OSAS)
    Shilliday, N.
    Bishopp, A.
    Chakraborty, B.
    Daniels, M.
    Mukherjee, R.
    THORAX, 2015, 70 : A134 - A134
  • [48] Five-year effects of nasal continuous positive airway pressure in obstructive sleep apnoea syndrome
    Chaouat, A
    Weitzenblum, E
    Kessler, R
    Oswald, M
    Sforza, E
    Liegeon, MN
    Krieger, J
    EUROPEAN RESPIRATORY JOURNAL, 1997, 10 (11) : 2578 - 2582
  • [49] Impact of treatment by continuous positive airway pressure on quality of life of patients with the obstructive sleep apnoea syndrome
    Lebrun, T
    Rolland, N
    Sailly, JC
    Meslier, N
    Racineux, JL
    PhilippJoet, F
    Fleury, B
    QUALITY OF LIFE RESEARCH, 1997, 6 (7-8) : 214 - 214
  • [50] Nasal continuous positive airway pressure: influence on digital volume pulse in obstructive sleep apnoea patients
    Scholze, Alexandra
    Lamwers, Stephanie
    Tepel, Martin
    Sanner, Bernd M.
    EUROPEAN RESPIRATORY JOURNAL, 2012, 39 (05) : 1127 - 1135