The infrared radiation thermometer is now becoming a very widely used instrument for industrial temperature measurement and hazardous temperature assessment. Its simple design allows a very low manufacturing cost, and hence its widespread adoption as a convenient non-contact thermometer. The spectral sensitivity of these instruments is usually set by the transmission properties of the windows on the pyrometer, and, although the manufacturer usually makes some statement as to the operating wavelength region, it is difficult to know exactly what is being reported. Calibration laboratories often require knowledge of the band-pass for appropriate calculations of uncertainty, corrections for blackbody emissivity, or, as is commonly becoming required, correction of blackbody radiance temperatures for the calibration of cheaper 'fixed emissivity (eg. 95%)' pyrometers. An explicit measurement of the spectral response of the pyrometer would require a tunable IR source, and special attention to the effects of ambient radiation. This paper presents a very simple experimental technique for the estimation of effective pass-band of an IR radiation thermometer using only a mesh and a blackbody radiator at several temperatures. An analysis of the uncertainty in this determination of the band-pass is also presented.
引用
收藏
页码:607 / 612
页数:6
相关论文
共 50 条
  • [41] Experimental study on narrow spectral width FP lasers with a wavelength detuned band-pass filter
    Fu, Junwei
    Xi, Yanping
    Li, Xun
    Hong, Wei
    Huang, Weiping
    OPTICAL REVIEW, 2017, 24 (04) : 483 - 488
  • [42] Experimental study on narrow spectral width FP lasers with a wavelength detuned band-pass filter
    Junwei Fu
    Yanping Xi
    Xun Li
    Wei Hong
    Weiping Huang
    Optical Review, 2017, 24 : 483 - 488
  • [43] Tunable graphene-based mid-infrared band-pass planar filter and its application
    Somayyeh Asgari
    Hossein Rajabloo
    Nosrat Granpayeh
    Homayoon Oraizi
    Chinese Physics B, 2018, (08) : 294 - 300
  • [44] Manufacturing and characterizing of all-dielectric band-pass filters for the short-wave infrared region
    Bauer, T.
    Lappschies, M.
    Schallenberg, U.
    Jakobs, S.
    ADVANCES IN OPTICAL THIN FILMS IV, 2011, 8168
  • [45] Proposal for a graphene nanoribbon assisted mid-infrared band-stop/band-pass filter based on Bragg gratings
    Janfaza, Morteza
    Mansouri-Birjandi, Mohammad Ali
    Tavousi, Alireza
    OPTICS COMMUNICATIONS, 2019, 440 : 75 - 82
  • [46] Comparative Experimental Research on the LEMP Protection Effects of RF Surge Arresters with Low-pass and Band-pass Frequency Characteristics
    Wang, Dongdong
    Chen, Xi
    Gao, Lan
    PROCEEDINGS OF 2017 7TH IEEE INTERNATIONAL SYMPOSIUM ON MICROWAVE, ANTENNA, PROPAGATION, AND EMC TECHNOLOGIES (MAPE), 2017, : 200 - 202
  • [47] High sensitive temperature sensor based on narrow band-pass filters via optical heterodyne technique
    Dheyaa A. Resen
    Jassim K. Hmood
    Mohammed F. Altemimi
    Sulaiman W. Harun
    Optical and Quantum Electronics, 2023, 55
  • [48] Mechanical resonance suppression technique for inertial reference unit based on band-pass filter disturbance observer
    Wang, Tianyu
    Tuo, Weixiao
    Li, Xingfei
    He, Mengjie
    Gao, Xiaoqing
    ISA TRANSACTIONS, 2024, 155 : 337 - 345
  • [49] Performance enhancement of band-pass FIR filter-based M-class phasor estimation
    Kumar, Mukesh
    Kumar, M. Senthil
    JOURNAL OF ELECTRICAL ENGINEERING-ELEKTROTECHNICKY CASOPIS, 2024, 75 (02): : 124 - 136
  • [50] High sensitive temperature sensor based on narrow band-pass filters via optical heterodyne technique
    Resen, Dheyaa A. A.
    Hmood, Jassim K. K.
    Altemimi, Mohammed F. F.
    Harun, Sulaiman W. W.
    OPTICAL AND QUANTUM ELECTRONICS, 2023, 55 (08)