Radar based technology for non-contact monitoring of accumulation of blood in the head: A numerical study

被引:11
|
作者
Oziel, Moshe [1 ]
Korenstein, Rafi [1 ]
Rubinsky, Boris [2 ]
机构
[1] Tel Aviv Univ, Sackler Sch Med, Dept Physiol & Pharmacol, Tel Aviv, Israel
[2] Univ Calif Berkeley, Dept Mech Engn, Berkeley, CA 94720 USA
来源
PLOS ONE | 2017年 / 12卷 / 10期
关键词
COMPUTED-TOMOGRAPHY; HEMATOMA GROWTH; ACUTE STROKE; BRAIN; RADIATION; ANTENNA; CT; HEMORRHAGE; SYSTEM; EDEMA;
D O I
10.1371/journal.pone.0186381
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background This theoretical study examines the use of radar to continuously monitor "accumulation of blood in the head" (ACBH) non-invasively and from a distance, after the location of a hematoma or hemorrhage in the brain was initially identified with conventional medical imaging. Current clinical practice is to monitor ABCH with multiple, subsequent, conventional medical imaging. The radar technology introduced in this study could provide a lower cost and safe alternative to multiple conventional medical imaging monitoring for ACBH. Materials and methods The goal of this study is to evaluate the feasibility of using radar to monitor changes in blood volume in the brain through a numerical simulation of ACBH monitoring from remote, with a directional spiral slot antennae, in 3-D models of the brain. The focus of this study is on evaluating the effect of frequencies on the antennae reading. To that end we performed the calculations for frequencies of 100 MHz, 500 MHz and 1 GHz. Results and discussion The analysis shows that the ACBH can be monitored with radar and the monitoring resolution improves with an increase in frequency, in the range studied. However, it also appears that when typical clinical dimensions of hematoma and hemorrhage are used, the variable ratio of blood volume radius and radar wavelength can bring the measurements into the Mie and Rayleigh regions of the radar cross section. In these regions there is an oscillatory change in signal with blood volume size. For some frequencies there is an increase in signal with an increase in volume while in others there is a decrease. Conclusions While radar can be used to monitor ACBH non-invasively and from a distance, the observed Mie region dependent oscillatory relation between blood volume size and wavelength requires further investigation. Classifiers, multifrequency algorithms or ultra-wide band radar are possible solutions that should be explored in the future.
引用
收藏
页数:20
相关论文
共 50 条
  • [31] Non-contact head laser tomography
    Huseyin Ozgur Kazanci
    Optical and Quantum Electronics, 2016, 48
  • [32] Non-contact head laser tomography
    Kazanci, Huseyin Ozgur
    OPTICAL AND QUANTUM ELECTRONICS, 2016, 48 (06)
  • [33] Non-Contact In-Vehicle Occupant Monitoring System Based on Point Clouds from FMCW Radar
    Chen, Yixuan
    Luo, Yunlong
    Ma, Jianhua
    Qi, Alex
    Huang, Runhe
    De Paulis, Francesco
    Qi, Yihong
    TECHNOLOGIES, 2023, 11 (02)
  • [34] A Novel Non-Contact Drunkenness Monitoring Technique Based on A 24-GHz Interferometric Radar System
    Ye, Yangtao
    Ma, Lina
    Liu, Jingtao
    Zhang, Zesheng
    Gu, Changzhan
    Mao, Jun-Fa
    2022 IEEE MTT-S INTERNATIONAL MICROWAVE BIOMEDICAL CONFERENCE (IMBIOC), 2022, : 296 - 298
  • [35] Non-contact heart beat monitoring using impulse-radio ultra-wide band radar technology
    Lim, Y. -H.
    Choi, Y. W.
    Park, J. Y.
    Lee, Y. G.
    Choi, J. W.
    Park, H. K.
    Cho, S. -H.
    Cho, S. H.
    EUROPEAN HEART JOURNAL, 2018, 39 : 888 - 888
  • [36] Non-contact Non-invasive Heart and Respiration Rates Monitoring with MIMO Radar Sensing
    Liu, Qiwei
    Guo, Hanqing
    Xu, Junhong
    Kageza, Aron
    AlQarni, Saeed
    Wu, Shaoen
    Wang, Honggang
    2018 IEEE GLOBAL COMMUNICATIONS CONFERENCE (GLOBECOM), 2018,
  • [37] Non-contact wheat moisture detection based on mmWave radar ToF
    Hu, Pengming
    Duan, Shanshan
    Yang, Weidong
    JOURNAL OF STORED PRODUCTS RESEARCH, 2025, 111
  • [38] Non-Contact Vibration Retrieval and Performance Analysis Based on LFMCW Radar
    Liao, Xin
    Liu, Shuai
    Xiang, Yin
    Ding, Zegang
    Yan, Xuemei
    2016 IEEE INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING, COMMUNICATIONS AND COMPUTING (ICSPCC), 2016,
  • [39] Non-Contact Respiratory Monitoring in Neonates
    Eastwood-Sutherland, Caillin
    Gale, Timothy J.
    Dargaville, Peter A.
    Wheeler, Kevin
    2014 7TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON), 2014,
  • [40] The study on numerical simulation of non-contact explosion impact response
    Jin jing
    Chen yan-feng
    Wu xing-yue
    7TH INTERNATIONAL CONFERENCE ON SYSTEM SIMULATION AND SCIENTIFIC COMPUTING ASIA SIMULATION CONFERENCE 2008, VOLS 1-3, 2008, : 914 - 917