Retention and Stability Characteristics of Soft-Liner and Clip Attachments Used for Bar/Implant-Assisted Mandibular Overdentures: An In Vitro Study

被引:1
|
作者
Denewar, Mohamed Mahmoud [1 ,2 ]
Abdelmawgood, Esam Ibraheim [3 ,4 ]
ELsyad, Moustafa Abdou [3 ,4 ]
Al-Tonbary, Gilan Youssef [3 ,4 ]
机构
[1] Delta Univ Sci & Technol, Fac Oral & Dent Med, Talkha, Egypt
[2] Fac Oral & Dent Med, Dept Removable Prosthodont, Eldakahlia, Egypt
[3] Univ Mansoura, Fac Dent, Eldakahlia, Egypt
[4] Univ Mansoura, Fac Dent, Dept Prosthodont, Eldakahlia, Egypt
关键词
attachment; clip; bar; implant; overdentures; retention; soft liner; stability; RETAINED IMPLANT OVERDENTURES; RESILIENT LINER; PERI-IMPLANT; MAXILLARY OVERDENTURES; PROSTHETIC ASPECTS; BAR; INCLINATION; FORCES; RESORPTION; DESIGNS;
D O I
10.11607/jomi.8862
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To investigate retention and stability characteristics of soft-liner and clip attachments used for bar/implant- assisted mandibular overdentures. Materials and Methods: Two implants were placed in an edentulous mandibular model. According to the type of bar, presence of cantilevers, and type of attachments, eight groups were tested: (1) DCC-Dolder bar with cantilevers and three titanium clips, (2) DLC-Dolder bar with cantilevers and resilient liner attachments, (3) DCWC-Dolder bar without cantilevers and one titanium clip, (4) DLWC-Dolder bar without cantilevers and resilient liner attachments, (5) HCC-Hader bar with cantilevers and three plastic clips, (6) HLC-Hader bar with cantilevers and resilient liner attachments, (7) HCWC-Hader bar without cantilevers and one plastic clip, and (8) HLWC-Hader bar without cantilever and resilient liner. Axial (retention) and nonaxial (stability during anterior, posterior, and lateral dislodging) forces were evaluated initially and after 540 times of prosthesis insertions and withdrawals. Results: The highest retention and stability forces were observed with HCC, and the lowest forces were recorded with DLWC. The lowest retention and stability after wear was noted with DCWC and HCWC. For the majority of groups, the highest forces were noted with posterior dislodgment, and the lowest forces were observed with lateral dislodgment. The largest retention loss was recorded with DCC and HCC, and the lowest retention loss was noted with HLWC. DLC and HLC showed retention gain. Conclusion: The Hader bar with clips and cantilever extensions achieved the highest retention and stability forces after wear simulation, while bars without cantilevers and clips showed the lowest forces. For cantilevered Dolder and Hader bars, clip attachments showed increased retention loss, while soft-liner attachments showed retention gain. Int J Oral Maxillofac Implants 2021;36:1095-1103. doi: 10.11607/jomi.8862
引用
收藏
页码:1095 / 1103
页数:9
相关论文
共 38 条
  • [21] In vitro study of a mandibular implant overdenture retained with ball, magnet, or bar attachments: Comparison of load transfer and denture stability
    Tokuhisa, M
    Matsushita, Y
    Koyano, K
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2003, 16 (02) : 128 - 134
  • [22] Implant-supported mandibular overdentures retained with ball or bar attachments: A randomized prospective 5-year study
    Gotfredsen, K
    Holm, B
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2000, 13 (02) : 125 - 130
  • [23] Resilient Stud Versus Bar Attachments for Inclined Implants Supporting Mandibular Overdentures. An In Vitro Study of and Strains
    Elhelbawy, Nahla Gamaleldin
    ELsyad, Moustafa Abdou
    Soliman, Tarek Ahmed
    Mahrous, Ahmed
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (05) : 982 - 988
  • [24] Retention of mandibular implant-retained overdentures with two different attachment designs: An in vitro study
    Ramadan, Rania E.
    Mohamed, Faten S.
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (05): : 738.e1 - 738.e6
  • [25] Hard and soft-tissue evaluation of bar-clip, ball-socket, and kerator attachments in mandibular implant overdenture treatment: An in vivo study
    Varshney, Nitish
    Gupta, Sakshi
    Aggarwal, Sun
    Kumar, Shalabh
    Sadish, M.
    Khan, Mohsin
    JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2019, 19 (04): : 296 - 306
  • [26] Initial retention force of three attachment systems for implant retained-mandibular overdentures: An in vitro study
    Wakam, Raphael
    Mawussi, Kwamivi B.
    Benoit, Aurelie
    Gorin, Caroline
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024, 33 (05): : 475 - 483
  • [27] Influence of Rigid Bar and Nonrigid Double Crown Attachments on Maxillary Implant Overdentures: An In Vitro Study with Differential Bone Quality
    Kimura, Toru
    Yang, Tsung-Chieh
    Maeda, Yoshinobu
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (04) : 764 - 769
  • [28] Accuracy of Selective Laser Melted Bar Retaining Mandibular Implant-Assisted Overdenture: An In Vitro Comparison of Different Impression Materials and Techniques
    El-Asfahani, Iman A.
    Ramdan, Amr S.
    Agamy, Emad M. T. M.
    JOURNAL OF ORAL IMPLANTOLOGY, 2023, 49 (06) : 590 - 598
  • [29] Retention and postinsertion maintenance of bar-clip, ball and magnet attachments in mandibular implant overdenture treatment:: an in vivo comparison after 3 months of function
    van Kampen, F
    Cune, M
    van der Bilt, A
    Bosman, F
    CLINICAL ORAL IMPLANTS RESEARCH, 2003, 14 (06) : 720 - 726
  • [30] Retention loss and wear assessment of three attachment systems for implant retained-mandibular overdentures: An in vitro study
    Wakam, Raphael
    Ramalingam, Srilakshmi
    Mawussi, Kwamivi Bernardin
    Gorin, Caroline
    Benoit, Aurelie
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2024, 150