Bleaching and microstructural effects of low concentration hydrogen peroxide photoactivated with LED/laser system on bovine enamel

被引:10
|
作者
de Sousa Gomes Costa, Joatan Lucas [1 ]
Besegato, Joao Felipe [1 ]
Kuga, Milton Carlos [1 ]
机构
[1] Sao Paulo State Univ UNESP, Sch Dent, Dept Restorat Dent, BR-14801903 Araraquara, SP, Brazil
关键词
Tooth whitening; Hydrogen peroxide; pH; LED; IN-SITU; VIOLET LIGHT; PH VALUES; SURFACE; COLOR; AGENTS; MICROHARDNESS; TEETH; LASER; GEL;
D O I
10.1016/j.pdpdt.2021.102352
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: Tooth whitening protocols with low concentration hydrogen peroxide (HP) appear to minimize the microstructural effect on teeth. In addition, light sources have been used to enhance bleaching efficiency. This study evaluated the color change and microhardness of a protocol with 6% HP photoactivated by LED/laser in comparison with 35% HP. Methods: Twenty bovine incisors were randomized in two groups: 6% HP + LED/laser and 35% HP (n=10). Teeth were submitted to staining using dark tea. Three whitening sessions were carried out according to the manufacturer's instructions. Enamel microhardness (VHN) and color change evaluation (Delta L*, Delta a*, Delta b*, Delta E-00 [CIEDE2000], and WID) before 24 hours and 7 days after the last whitening session were performed. Two-way repeated ANOVA and Bonferroni post-test was used (alpha = 0.05). Results: Both groups showed perceptible color changes, being more pronounce for 35% HP. Differences were observed for Delta a*, Delta b* and Delta E-00 (p <= 0.027), except for Delta L* (p>0.05). Differences were also found in the comparison among the evaluation times within the same group (p <= 0.027), except for Delta a* results (p>0.05). WID showed that 35% HP exhibited high whiteness values. Regarding microhardness, the groups did not show significant differences (p>0.05). However, 35% HP showed decreased values after 7 days of the last whitening session compared to the baseline (p <= 0.027). Conclusions: 6% HP + LED/laser promoted perceptible color change, but not comparable with 35% HP. No differences on enamel microhardness were observed between the whitening protocols. However, 35% HP showed decreased hardness after 7 days of whitening compared to baseline.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] In vitro bleaching effect of hydrogen peroxide with different time of exposition and concentration on shear bond strength of orthodontic brackets to human enamel: A meta-analysis of in vitro studies
    Imani, Mohammad Moslem
    Azizi, Fatemeh
    Bahrami, Kiana
    Golshah, Amin
    Safari-Faramani, Roya
    INTERNATIONAL ORTHODONTICS, 2020, 18 (01) : 22 - 31
  • [42] Enamel Mineral Content Changes After Bleaching With High and Low Hydrogen Peroxide Concentrations: Colorimetric Spectrophotometry and Total Reflection X-ray Fluorescence Analyses
    Pinto, A. V. D.
    Bridi, E. C.
    Amaral, F. L. B.
    Franca, F. M. G.
    Turssi, C. P.
    Perez, C. A.
    Martinez, E. F.
    Florio, F. M.
    Basting, R. T.
    OPERATIVE DENTISTRY, 2017, 42 (03) : 308 - 318
  • [43] Longevity, Esthetic Perception, and Psychosocial Impact of Teeth Bleaching by Low (6%) Hydrogen Peroxide Concentration for In-office Treatment: A Randomized Clinical Trial
    Fernandez, E.
    Bersezio, C.
    Bottner, J.
    Avalos, F.
    Godoy, I.
    Inda, D.
    Vildosola, P.
    Saad, J. R. C.
    Oliveira, O. B., Jr.
    Martin, J.
    OPERATIVE DENTISTRY, 2017, 42 (01) : 41 - 52
  • [44] Three-monthevaluation of a low concentration (6% hydrogen peroxide) experimental bleaching gel containing Tio2and chitosan: An in vitro study
    Kolsuz Ozcetin, Halime
    Surmelioglu, Derya
    COLOR RESEARCH AND APPLICATION, 2020, 45 (06): : 1101 - 1108
  • [45] LED and low level laser therapy association in tooth bleaching using a novel low concentration H2O2/N-doped TiO2 bleaching agent
    Dias, Hercules Bezerra
    Carrera, Emanuelle Teixeira
    Bortolatto, Janania Freitas
    de Andrade, Marcelo Ferrarezi
    de Souza Rastelli, Alessandra Nara
    LASER PHYSICS, 2016, 26 (01)
  • [46] Effects of energy and hydrogen peroxide concentration on structural and optical properties of CuO nanosheets prepared by pulsed laser ablation
    Azadi, H.
    Aghdam, H. Dizajghorbani
    Malekfar, R.
    Bellah, S. Moemen
    RESULTS IN PHYSICS, 2019, 15
  • [47] An In Vitro Study on the Effects of Hydrogen Peroxide-Based Bleaching Agents on Enamel: Field Emission Scanning Electron Microscopy (FESEM) With Energy Dispersive Spectroscopy (EDS) Evaluation
    Sreelakshmi, P. S.
    Karumaran, Chellaswamy Savrimalai
    Arjun, R. S.
    Manuel, Corrine Esther
    Christy, V. Jevina
    Stalin, Roselin
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (04)
  • [48] Effects of Sodium Chloride and Long-Term, Low-Concentration Exposures to Hydrogen Peroxide on New Zealand Mud Snails
    Oplinger, Randall W.
    Wagner, Eric J.
    NORTH AMERICAN JOURNAL OF AQUACULTURE, 2015, 77 (01) : 31 - 36
  • [49] Fourier Transform-Raman and Reflectance Studies on Dental Enamel Bleached with Hydrogen Peroxide Activated Using a Light-Emitting Diode-Laser System
    Rosia Cesar, Ilene Cristine
    Silva Soares, Luis Eduardo
    Alves, Leandro Procopio
    Martin, Airton Abrahao
    Munin, Egberto
    Suzy Liporoni, Priscila Christiane
    PHOTOMEDICINE AND LASER SURGERY, 2009, 27 (06) : 913 - 919
  • [50] Teeth bleaching with low concentrations of hydrogen peroxide (6%) and catalyzed by LED blue (450 ± 10 nm) and laser infrared (808 ± 10 nm) light for in-office treatment: Randomized clinical trial 1-year follow-up
    Vildosola, Patricio
    Bottner, Jessica
    Avalos, Francisca
    Godoy, Isidora
    Martin, Javier
    Fernandez, Eduardo
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2017, 29 (05) : 339 - 345