Towards real-time thermometry using simultaneous multislice MRI

被引:15
|
作者
Borman, P. T. S. [1 ,2 ]
Bos, C. [2 ]
de Boorder, T. [3 ]
Raaymakers, B. W. [1 ]
Moonen, C. T. W. [2 ]
Crijns, S. P. M. [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Radiotherapy, Heidelberglaan 100, NL-3584 CX Utrecht, Netherlands
[2] Univ Med Ctr Utrecht, Imaging Div, Heidelberglaan 100, NL-3584 CX Utrecht, Netherlands
[3] Univ Med Ctr Utrecht, Med Technol & Clin Phys, Heidelberglaan 100, NL-3584 CX Utrecht, Netherlands
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2016年 / 61卷 / 17期
关键词
MR-guided therapy; thermal therapy; MR thermometry; multiband imaging; simultaneous multislice imaging; SIGNAL-TO-NOISE; THERMAL THERAPY; TEMPERATURE; HIFU; RECONSTRUCTION; ABLATION; BRAIN; SHIFT;
D O I
10.1088/0031-9155/61/17/N461
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
MR-guided thermal therapies, such as high-intensity focused ultrasound (MRgHIFU) and laser-induced thermal therapy (MRgLITT) are increasingly being applied in oncology and neurology. MRI is used for guidance since it can measure temperature noninvasively based on the proton resonance frequency shift (PRFS). For therapy guidance using PRFS thermometry, high temporal resolution and large spatial coverage are desirable. We propose to use the parallel imaging technique simultaneous multislice (SMS) in combination with controlled aliasing (CAIPIRINHA) to accelerate the acquisition. We compare this with the sensitivity encoding (SENSE) acceleration technique. Two experiments were performed to validate that SMS can be used to increase the spatial coverage or the temporal resolution. The first was performed in agar gel using LITT heating and a gradient-echo sequence with echo-planar imaging (EPI), and the second was performed in bovine muscle using HIFU heating and a gradient-echo sequence without EPI. In both experiments temperature curves from an unaccelerated scan and from SMS, SENSE, and SENSE/ SMS accelerated scans were compared. The precision was quantified by a standard deviation analysis of scans without heating. Both experiments showed a good agreement between the temperature curves obtained from the unaccelerated, and SMS accelerated scans, confirming that accuracy was maintained during SMS acceleration. The standard deviations of the temperature measurements obtained with SMS were significantly smaller than when SENSE was used, implying that SMS allows for higher acceleration. In the LITT and HIFU experiments SMS factors up to 4 and 3 were reached, respectively, with a loss of precision of less than a factor of 3. Based on these results we conclude that SMS acceleration of PRFS thermometry is a valuable addition to SENSE, because it allows for a higher temporal resolution or bigger spatial coverage, with a higher precision.
引用
收藏
页码:N461 / N477
页数:17
相关论文
共 50 条
  • [31] Real-time MRI angioplasty using intravascular guidewire coils
    Dick, AJ
    Guttman, MA
    Raman, VK
    Peters, DC
    Thompson, RB
    Lederman, RJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (05) : 352A - 352A
  • [32] A NEW METHOD FOR VOLUME MRI USING SIMULTANEOUS MULTISLICE ACQUISITION SIMA
    PLEWES, DB
    SZUMOWSKI, J
    DUMOULIN, CR
    SOUZA, SP
    MEDICAL PHYSICS, 1987, 14 (04) : 709 - 710
  • [33] Simultaneous T2-weighted real-time MRI of two orthogonal slices
    Hickey, Samantha
    Reichert, Andreas
    Ptacek, Wolfgang
    Bielak, Lars
    Reiss, Simon
    Fischer, Johannes
    Gunashekar, Deepa Darshini
    Bortfeld, Thomas
    Bock, Michael
    MAGNETIC RESONANCE IN MEDICINE, 2023, 90 (06) : 2388 - 2399
  • [34] Simultaneous multi-slice cardiac real-time MRI at 0.55T
    Yagiz, Ecrin
    Garg, Parveen
    Cen, Steven Y.
    Nayak, Krishna S.
    Tian, Ye
    MAGNETIC RESONANCE IN MEDICINE, 2024,
  • [35] Simultaneous multi-slice cardiac real-time MRI at 0.55T
    Yagiz, Ecrin
    Garg, Parveen
    Cen, Steven Y.
    Nayak, Krishna S.
    Tian, Ye
    MAGNETIC RESONANCE IN MEDICINE, 2025, 93 (04) : 1723 - 1732
  • [36] Real-time millikelvin thermometry in a semiconductor-qubit architecture
    Champain, V.
    Schmitt, V.
    Bertrand, B.
    Niebojewski, H.
    Maurand, R.
    Jehl, X.
    Winkelmann, C. B.
    De Franceschi, S.
    Brun, B.
    PHYSICAL REVIEW APPLIED, 2024, 21 (06):
  • [37] Real-Time MR Thermometry for Monitoring HIFU Ablations of the Liver
    Holbrook, Andrew B.
    Santos, Juan M.
    Kaye, Elena
    Rieke, Viola
    Pauly, Kim Butts
    MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (02) : 365 - 373
  • [38] Real-time nanodiamond thermometry probing in vivo thermogenic responses
    Fujiwara, Masazumi
    Sun, Simo
    Dohms, Alexander
    Nishimura, Yushi
    Suto, Ken
    Takezawa, Yuka
    Oshimi, Keisuke
    Zhao, Li
    Sadzak, Nikola
    Umehara, Yumi
    Teki, Yoshio
    Komatsu, Naoki
    Benson, Oliver
    Shikano, Yutaka
    Kage-Nakadai, Eriko
    SCIENCE ADVANCES, 2020, 6 (37):
  • [39] Towards real-time forest inventory using handheld LiDAR
    Proudman, Alexander
    Ramezani, Milad
    Digumarti, Sundara Tejaswi
    Chebrolu, Nived
    Fallon, Maurice
    ROBOTICS AND AUTONOMOUS SYSTEMS, 2022, 157
  • [40] Towards real-time object recognition using pairs of lines
    Meikle, S
    Amavasai, BP
    Caparrelli, F