Towards real-time thermometry using simultaneous multislice MRI

被引:15
|
作者
Borman, P. T. S. [1 ,2 ]
Bos, C. [2 ]
de Boorder, T. [3 ]
Raaymakers, B. W. [1 ]
Moonen, C. T. W. [2 ]
Crijns, S. P. M. [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Radiotherapy, Heidelberglaan 100, NL-3584 CX Utrecht, Netherlands
[2] Univ Med Ctr Utrecht, Imaging Div, Heidelberglaan 100, NL-3584 CX Utrecht, Netherlands
[3] Univ Med Ctr Utrecht, Med Technol & Clin Phys, Heidelberglaan 100, NL-3584 CX Utrecht, Netherlands
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2016年 / 61卷 / 17期
关键词
MR-guided therapy; thermal therapy; MR thermometry; multiband imaging; simultaneous multislice imaging; SIGNAL-TO-NOISE; THERMAL THERAPY; TEMPERATURE; HIFU; RECONSTRUCTION; ABLATION; BRAIN; SHIFT;
D O I
10.1088/0031-9155/61/17/N461
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
MR-guided thermal therapies, such as high-intensity focused ultrasound (MRgHIFU) and laser-induced thermal therapy (MRgLITT) are increasingly being applied in oncology and neurology. MRI is used for guidance since it can measure temperature noninvasively based on the proton resonance frequency shift (PRFS). For therapy guidance using PRFS thermometry, high temporal resolution and large spatial coverage are desirable. We propose to use the parallel imaging technique simultaneous multislice (SMS) in combination with controlled aliasing (CAIPIRINHA) to accelerate the acquisition. We compare this with the sensitivity encoding (SENSE) acceleration technique. Two experiments were performed to validate that SMS can be used to increase the spatial coverage or the temporal resolution. The first was performed in agar gel using LITT heating and a gradient-echo sequence with echo-planar imaging (EPI), and the second was performed in bovine muscle using HIFU heating and a gradient-echo sequence without EPI. In both experiments temperature curves from an unaccelerated scan and from SMS, SENSE, and SENSE/ SMS accelerated scans were compared. The precision was quantified by a standard deviation analysis of scans without heating. Both experiments showed a good agreement between the temperature curves obtained from the unaccelerated, and SMS accelerated scans, confirming that accuracy was maintained during SMS acceleration. The standard deviations of the temperature measurements obtained with SMS were significantly smaller than when SENSE was used, implying that SMS allows for higher acceleration. In the LITT and HIFU experiments SMS factors up to 4 and 3 were reached, respectively, with a loss of precision of less than a factor of 3. Based on these results we conclude that SMS acceleration of PRFS thermometry is a valuable addition to SENSE, because it allows for a higher temporal resolution or bigger spatial coverage, with a higher precision.
引用
收藏
页码:N461 / N477
页数:17
相关论文
共 50 条
  • [1] Towards Real-Time PRFS Thermometry Using Simultaneous MultiSlice Acquisitions
    Borman, P.
    Crijns, S.
    Bos, C.
    Moonen, C.
    Raaymakers, B.
    MEDICAL PHYSICS, 2015, 42 (06) : 3263 - 3263
  • [2] Improved imaging of lingual articulation using real-time multislice MRI
    Kim, Yoon-Chul
    Proctor, Michael I.
    Narayanan, Shrikanth S.
    Nayak, Krishna S.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 35 (04) : 943 - 948
  • [3] Rapid ventricular assessment using real-time interactive multislice MRI
    Nayak, KS
    Pauly, JM
    Nishimura, DG
    Hu, BS
    MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (03) : 371 - 375
  • [4] Predicting liver ablation volumes with real-time MRI thermometry
    Ocal, Osman
    Dietrich, Olaf
    Lentini, Sergio
    Bour, Pierre
    Faller, Thibaut
    Ozenne, Valery
    Maier, Florian
    Fabritius, Matthias Philipp
    Puhr-Westerheide, Daniel
    Schmidt, Vanessa F.
    Oecal, Elif
    Seidensticker, Ricarda
    Wildgruber, Moritz
    Ricke, Jens
    Seidensticker, Max
    JHEP REPORTS, 2024, 6 (11)
  • [5] Simultaneous multislice MRI thermometry with a single coil using incoherent blipped-controlled aliasing
    Quah, Kristin
    Poorman, Megan E.
    Allen, Steven P.
    Grissom, William A.
    MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (02) : 479 - 491
  • [6] Real-Time Ultrasound Thermography and Thermometry
    Ebbini, Emad S.
    Simon, Claudio
    Liu, Dalong
    IEEE SIGNAL PROCESSING MAGAZINE, 2018, 35 (02) : 166 - 174
  • [7] Towards accurate real-time luminescence thermometry: An automated machine learning approach
    Santos, Emanuel P.
    Pugina, Roberta S.
    Hilario, Eloisa G.
    Carvalho, Alyson J. A.
    Jacinto, Carlos
    Rego-Filho, Francisco A. M. G.
    Canabarro, Askery
    Gomes, Anderson S. L.
    Caiut, Jose Mauricio A.
    Moura, Andre L.
    SENSORS AND ACTUATORS A-PHYSICAL, 2023, 362
  • [8] Real-time interactive multislice MRI: Stress LV function and first pass perfusion
    Nayak, KS
    Hu, BS
    Pauly, JM
    Putz, EJ
    Kerr, AB
    Nishimura, DG
    CIRCULATION, 2000, 102 (18) : 687 - 687
  • [9] Real-Time Thermal Imaging based on the Simultaneous Rise and Decay Luminescence Lifetime Thermometry
    Avram, Daniel
    Porosnicu, Ioana
    Patrascu, Andrei
    Tiseanu, Carmen
    ADVANCED PHOTONICS RESEARCH, 2022, 3 (06):
  • [10] Real-time MRI using gradient echoes
    Riederer, SJ
    Busse, RF
    Fain, SB
    Kruger, DG
    ULTRAFAST MAGNETIC RESONANCE IMAGING IN MEDICINE, 1999, 1192 : 103 - 109