Fab fragments imprinted SPR biosensor for real-time human immunoglobulin G detection

被引:87
|
作者
Erturk, Gizem [2 ]
Uzun, Lokman [1 ]
Tumer, M. Askin [2 ]
Say, Ridvan [3 ]
Denizli, Adil
机构
[1] Hacettepe Univ, Dept Chem, Fac Sci, Div Biochem, TR-06532 Ankara, Turkey
[2] Hacettepe Univ, Dept Biol, TR-06532 Ankara, Turkey
[3] Anadolu Univ, Dept Chem, Eskisehir, Turkey
来源
BIOSENSORS & BIOELECTRONICS | 2011年 / 28卷 / 01期
关键词
F-ab fragment; F-c fragment; Molecular imprinted polymers; Surface plasmon resonance sensors; Immunoglobulin G detection; ADSORPTION; AUTOANTIBODIES; PURIFICATION; SEPARATION; POLYMERS; MONOLITH; ANTIBODY; REMOVAL; SENSORS; PLASMA;
D O I
10.1016/j.bios.2011.07.004
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
F-ab fragments imprinted surface plasmon resonance (SPR) chip was prepared for the real-time detection of human immunoglobulin G (IgG). In order to attach polymerization precursor on SPR chip, the SPR chip surface was modified with allyl mercaptan. F-ab fragments of the IgG molecules were prepared by papain digestion procedure and collected by fast protein liquid chromatography (FPLC) system using Hi-Trap_r Protein A FF column. The collected Fab fragments were complexed with histidine containing specific monomer, N-methacryloyl-L-histidine methyl ester (MAH). Molecular imprinted polymeric nanofilm was prepared on SPR chip in the presence of ethylene glycol dimethacrylate and 2-hydroxyethylmethacrylate. The template molecules, F-ab fragments, were removed from the polymeric nanofilm using 1 M NaCl solution (pH: 7.4, phosphate buffer system). The molecular imprinted SPR chip was characterized by contact angle, atomic force microscopy and Fourier transform infrared spectroscopy. By the real-time IgG detection studies carried out using aqueous IgG solutions in different concentrations, the kinetics and isotherm parameters of the molecular imprinted SPR chip-IgG system were calculated. To show selectivity and specificity of the molecular imprinted SPR chip, competitive kinetic analyses were performed using bovine serum albumin (BSA), IgG, F-ab and F-c fragments in singular and competitive manner. As last step. IgG detection studies from human plasma were performed and the measured IgG concentrations were well matched with the results determined by enzyme-linked immunosorbent assay (ELISA). The results obtained with the molecular imprinted SPR chip were well fitted to Langmuir isotherm and the detection limit was found as 56 ng/mL. In the light of the results, we can conclude that the proposed molecular imprinted SPR chip can detect IgG molecules from both aqueous solutions and complex natural samples. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:97 / 104
页数:8
相关论文
共 50 条
  • [21] Real-time biosensor application of structurally chiral medium for detection and sensing of plasma in human blood
    Ghorani, Nadia
    Madani, Amir
    Entezar, Samad Roshan
    PHYSICA SCRIPTA, 2023, 98 (05)
  • [22] ISOLATION OF FAB AND FC FRAGMENTS FROM MOUSE IMMUNOGLOBULIN-G1
    BELYAEVA, EL
    NIKONENKO, BV
    SIDOROVA, EV
    BULLETIN OF EXPERIMENTAL BIOLOGY AND MEDICINE, 1979, 88 (07) : 811 - 813
  • [23] Enhanced wavelength modulation SPR biosensor based on gold nanorods for immunoglobulin detection
    Zhang, Hua
    Song, Daqian
    Gao, Shang
    Zhang, Hanqi
    Zhang, Jia
    Sun, Ying
    TALANTA, 2013, 115 : 857 - 862
  • [24] ENZYMATIC REOXIDATION OF FAB FRAGMENTS OF COMPLETELY REDUCED GAMMA-G IMMUNOGLOBULIN
    PERY, P
    FOUGEREAU, M
    BULLETIN DE LA SOCIETE DE CHIMIE BIOLOGIQUE, 1968, 50 (5-6): : 1023 - +
  • [25] Real-time detection of lymphocytes binding on an antibody chip using SPR imaging
    Suraniti, Emmanuel
    Sollier, Elodie
    Calemczuk, Roberto
    Livache, Thierry
    Marche, Patrice N.
    Villiers, Marie-Bernadette
    Roupioz, Yoann
    LAB ON A CHIP, 2007, 7 (09) : 1206 - 1208
  • [26] PURIFICATION OF FAB AND FC FRAGMENTS FROM HUMAN-SERUM IMMUNOGLOBULIN-G BY ELECTROPHORESIS AND AFFINITY CHROMATOGRAPHY
    DELAFARGE, F
    VALDIGUIE, P
    JOURNAL OF CHROMATOGRAPHY, 1976, 123 (01): : 247 - 250
  • [27] Determination of immunoglobulin G in bovine colostrum and milk by direct biosensor SPR-immunoassay
    Indyk, HE
    Filonzi, EL
    JOURNAL OF AOAC INTERNATIONAL, 2003, 86 (02) : 386 - 393
  • [28] Regenerative Surface Plasmon Resonance (SPR) biosensor: Real-time measurement of fibrinogen in undiluted human serum using the competitive adsorption of proteins
    Wang, Ran
    Lajevardi-Khosh, Arad
    Choi, Seokheun
    Chae, Junseok
    BIOSENSORS & BIOELECTRONICS, 2011, 28 (01): : 304 - 307
  • [29] Detection of Listeria monocytogenes through real-time PCR and biosensor methods
    Poltronieri, P.
    de Blasi, M. D.
    D'Urso, O. F.
    PLANT SOIL AND ENVIRONMENT, 2009, 55 (09) : 363 - 369
  • [30] Real-time liquid crystal-based biosensor for urea detection
    Khan, Mashooq
    Kim, Youngkyoo
    Lee, Joon Hyung
    Kang, Inn-Kyu
    Park, Soo-Young
    ANALYTICAL METHODS, 2014, 6 (15) : 5753 - 5759