The Lund Nuclear Microprobe sub-micron set-up.: Part I:: Ion optics calculation

被引:16
|
作者
Shariff, A
Auzelyte, V
Elfman, M
Kristiansson, P
Malmqvist, K
Nilsson, C
Pallon, J
Wegdén, M
机构
[1] Lund Univ, Inst Technol, Dept Nucl Phys, S-22100 Lund, Sweden
[2] Atom Energy Ctr, Accelerator Facil Div, Dhaka 1000, Bangladesh
关键词
ion optics; nuclear microprobe; sub-micron beam; PRAM; OXTRACE;
D O I
10.1016/j.nimb.2005.01.026
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A new beam line for generating a sub-micron beam spot for high-resolution nuclear microprobe applications has been constructed at the Lund nuclear microprobe facility. In this paper, the first in a series of three, a detailed theoretical investigation of different focusing systems is presented based on calculations performed with the computer programs PRAM and OXTRACE. Comparison is made between a doublet, a triplet, a quadruplet and a split quadruplet (two-stage focusing). For the split quadruplet all four quadrupole magnets were uncoupled. The conclusion from the calculations was that to obtain the smallest possible beam, the two-stage focusing system should be used. Such a focusing system (a doublet at each stage) has been chosen for the new sub-micron set-up at the Lund NMP laboratory. The first stage focuses the beam in an intermediate chamber, which has a high-resolution optical viewing system facilitating more control over the beam spot. This real image of the first stage is then used as a virtual object for the second stage. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 6
页数:6
相关论文
共 4 条
  • [1] The Lund Nuclear Microprobe sub-micron set-up.: Part II:: Beam line, focusing system and scanning
    Shariff, A
    Nilsson, C
    Auzelyte, V
    Elfman, M
    Kristiansson, P
    Malmqvist, K
    Pallon, J
    Wegdén, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2005, 231 : 7 - 13
  • [2] The Lund Nuclear Microprobe sub-micron set-up.: Part III:: Sample stage, optical imaging and detector configuration in the experimental chamber
    Elfman, M
    Pallon, J
    Auzelyte, V
    Kristiansson, P
    Malmqvist, K
    Nilsson, C
    Shariff, A
    Wegdén, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2005, 231 : 14 - 20
  • [3] Analytical modelling of the current (I)-voltage (V) characteristics of sub-micron gate-length ion-implanted GaAs MESFETs under dark and illuminated conditions
    Tripathi, Shweta
    Jit, Satyabrata
    IET CIRCUITS DEVICES & SYSTEMS, 2013, 7 (01) : 42 - 50
  • [4] Ultra-Stable Molecular Sensors by Sub-Micron Referencing and Why They Should Be Interrogated by Optical Diffraction-Part I. The Concept of a Spatial Affinity Lock-in Amplifier
    Frutiger, Andreas
    Fattinger, Christof
    Voros, Janos
    SENSORS, 2021, 21 (02) : 1 - 20