Validation and performance comparison of different types of combined scintillation detectors for animal PET imaging system using GATE simulation

被引:2
|
作者
Sadremomtaz, A. [1 ]
Ghalebin, M. Mohammadi [1 ]
机构
[1] Univ Guilan, Dept Phys, Namjoo St, Rasht, Iran
关键词
Detector modelling and simulations I (interaction of radiation with matter; interaction of photons with matter; interaction of hadrons with matter; etc); Detector modelling and simulations II (electric fields; charge transport; multiplication and induction; pulse formation; electron emission; Photon detectors for UV; visible and IR photons (vacuum) (photomultipliers; HPDs; others); Radiation-induced secondary-electron emission; SCANNER; NEMA;
D O I
10.1088/1748-0221/17/05/T05017
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The selection of suitable high-efficiency scintillation detectors plays an essential role in improving the quality of PET images. Many studies have used two layers of crystal detectors with different scintillation materials. This research uses GATE simulation to simulate an animal PET system with a two-layer detector. By varying the type of the crystal detectors, essential parameters such as sensitivity, scatter fraction, noise equivalent counting rate, spatial resolution, energy resolution, and time resolution for different scintillation materials were calculated and compared to determine the most efficient solutions. This simulation used scintillating materials; LYSO, GSO, LSO, BGO, YAP, LuAP, and LPS in 12 different states. Results showed that by increasing the distance of the source from the center in the radial direction, the two-layer crystals with different scintillation materials have a better radial spatial resolution than the same material of crystals. As a general result, the PET system???s performance, designed from two-layer crystals with different scintillation materials, lower layer LuAP and upper layer BGO or same-material of BGO, is more desirable than the rest.
引用
收藏
页数:13
相关论文
共 23 条
  • [1] Preliminary PET performance of the detectors for OPET: A combined optical and PET imaging system
    Chung, Y. H.
    Douraghy, A.
    Rannou, F. R.
    Silverman, R. W.
    Chatziioannou, A. F.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 1960 - 1964
  • [2] Validation of the Inveon small animal PET system model using GATE
    Dartial, N.
    Carlier, T.
    Fusellier, M.
    Desfontis, J.
    Visvikis, D.
    Bardies, M.
    Hindorf, C.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : S411 - S411
  • [3] Validation of a simultaneous PET/MR system model for PET simulation using GATE
    Florian Monnier
    Hadi Fayad
    Julien Bert
    Holger Schmidt
    Dimitris Visvikis
    EJNMMI Physics, 2 (Suppl 1)
  • [4] Validation of GATE Monte Carlo simulation of the performance characteristics of a GE eXplore VISTA small animal PET system
    Yang, C. C.
    Seidel, J.
    Wang, Y.
    Lee, J. S.
    Pomper, M. G.
    Tsui, B. M. W.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3187 - +
  • [5] Comparison of photon counting and conventional scintillation detectors in pinhole SPECT system for small animal imaging
    Lee, Young-Jin
    Ryu, Hyun-Ju
    Park, Su-Jin
    Kim, Hee-Joung
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [6] Comparison of photon counting and conventional scintillation detectors in a pinhole SPECT system for small animal imaging: Monte carlo simulation studies
    Young-Jin Lee
    Su-Jin Park
    Seung-Wan Lee
    Dae-Hong Kim
    Ye-Seul Kim
    Hee-Joung Kim
    Journal of the Korean Physical Society, 2013, 62 : 1317 - 1322
  • [7] Comparison of photon counting and conventional scintillation detectors in a pinhole SPECT system for small animal imaging: Monte carlo simulation studies
    Lee, Young-Jin
    Park, Su-Jin
    Lee, Seung-Wan
    Kim, Dae-Hong
    Kim, Ye-Seul
    Kim, Hee-Joung
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2013, 62 (09) : 1317 - 1322
  • [8] Validation of the GATE Monte Carlo simulation platform for modelling a CsI(Tl) scintillation camera dedicated to small-animal imaging
    Lazaro, D
    Buvat, I
    Loudos, G
    Strul, D
    Santin, G
    Giokaris, N
    Donnarieix, D
    Maigne, L
    Spanoudaki, V
    Styliaris, S
    Staelens, S
    Breton, V
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (02): : 271 - 285
  • [9] Monte Carlo based performance assessment of different animal PET architectures using pixellated CZT detectors
    Visvikis, D.
    Lefevre, T.
    Lamare, F.
    Kontaxakis, G.
    Santos, A.
    Darambara, D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 569 (02): : 225 - 229
  • [10] Monte Carlo simulation of MAMMI PET system and performance evaluation using GATE toolkit
    Emami, A.
    Ghadiri, H.
    Ghafarian, P.
    Geramifar, P.
    Ay, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S714 - S714