A sensitive voltammetric sensor for methamphetamine determination based on modified glassy carbon electrode using Fe3O4@poly pyrrole core-shell and graphene oxide

被引:14
|
作者
Riahifar, Vahid [1 ]
Haghnazari, Nahid [1 ]
Keshavarzi, Fatemeh [1 ]
Ahmadi, Elahe [2 ]
机构
[1] Islamic Azad Univ, Dept Biol, Sanandaj Branch, Sanandaj, Iran
[2] Islamic Azad Univ, Dept Fundamental Sci, Cent Tehran Branch, Tehran, Iran
关键词
Methamphetamine; Graphene oxide; Fe3O4@PPy core-shell; Glassy carbon electrode; Square wave voltammetry; MAGNETIC NANOPARTICLES; ELECTROCHEMICAL-BEHAVIOR; SURFACE MODIFICATION; POLYPYRROLE; EXTRACTION; BIOSENSOR; SCREEN; URINE; METAL; FILM;
D O I
10.1016/j.microc.2021.106748
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper introduced a sensitive sensor based on modified glassy carbon electrode using Fe3O4@PPy core-shell and electrochemically reduced graphene oxide (ErGO) to determine methamphetamine (MET). Field emission scanning electron microscopy (FE-SEM) and electrochemical impedance spectroscopy (EIS) was utilized to describe the proposed sensor characterization (Fe3O4@PPy/ErGO/GCE). The sensor's electrochemical activity was investigated by cyclic voltammetry (CV) and square wave voltammetry (SWV) technique to monitor MET in the Britton Robinson buffer solution (BR, pH 8) containing KCl 0.1 M. Prepared sensor (Fe3O4@PPy/ErGO/GCE) exhibited a better analytical performance compared with other modified electrodes for MET. Under optimized conditions, the proposed sensor offered linearity ranging from 0.005 mu M to 200 mu M with a detection limit of 1 nM. Notably, the fabricated sensor represented good reproducibility, outstanding sensitivity, and long-term performance. These results indicate that the proposed sensor is a promising candidate for MET determination in urine and serum samples.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Electrochemical Determination of Sulfonamide Based on Glassy Carbon Electrode Modified by Fe3O4/Functionalized Graphene
    He, Baoshan
    Yan, Sasa
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (04): : 3001 - 3011
  • [22] Voltammetric determination of florfenicol by using poly(3-methylthiophene) modified glassy carbon electrode
    Taskin, Imren
    Gungor, Oznur
    Titretir Duran, Serap
    [J]. POLYMER BULLETIN, 2021, 78 (08) : 4721 - 4741
  • [23] Voltammetric determination of florfenicol by using poly(3-methylthiophene) modified glassy carbon electrode
    İmren Taşkın
    Öznur Güngör
    Serap Titretir Duran
    [J]. Polymer Bulletin, 2021, 78 : 4721 - 4741
  • [24] Voltammetric determination of catechol based on a glassy carbon electrode modified with a composite consisting of graphene oxide and polymelamine
    Palanisamy, Selvakumar
    Ramaraj, Sayee Kannan
    Chen, Shen-Ming
    Velusamy, Vijayalakshmi
    Yang, Thomas C. K.
    Chen, Tse-Wei
    [J]. MICROCHIMICA ACTA, 2017, 184 (04) : 1051 - 1057
  • [25] Voltammetric determination of catechol based on a glassy carbon electrode modified with a composite consisting of graphene oxide and polymelamine
    Selvakumar Palanisamy
    Sayee Kannan Ramaraj
    Shen-Ming Chen
    Vijayalakshmi Velusamy
    Thomas C. K. Yang
    Tse-Wei Chen
    [J]. Microchimica Acta, 2017, 184 : 1051 - 1057
  • [26] Enhanced electromagnetic wave absorption performance of core-shell Fe3O4@poly(3,4-ethylenedioxythiophene) microspheres/reduced graphene oxide composite
    Liu, Xudong
    Zhao, Xiaoxiao
    Yan, Jing
    Huang, Ying
    Li, Tiehu
    Liu, Panbo
    [J]. CARBON, 2021, 178 : 273 - 284
  • [27] Sensitive voltammetric determination of paracetamol by poly (4-vinylpyridine)/multiwalled carbon nanotubes modified glassy carbon electrode
    Ghadimi, Hanieh
    Tehrani, Ramin M. A.
    Ali, Abdussalam Salhin Mohamed
    Mohamed, Norita
    Ab Ghani, Sulaiman
    [J]. ANALYTICA CHIMICA ACTA, 2013, 765 : 70 - 76
  • [28] Magnetic Core-shell Fe3O4@SiO2/Graphene Nanocomposite Modified Carbon Paste Electrode for Voltammetric Determination of Ascorbic Acid in the presence of L-Cysteine
    Nejad, Fariba Garkani
    Beitollahi, Hadi
    Shakeri, Shahryar
    [J]. ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2016, 8 (03): : 318 - 328
  • [29] Sensitive Voltammetric Determination of Paracetamol on Poly(4-Aminobenzene Sulfonic Acid) Modified Glassy Carbon Electrode
    Yilmaz, Selehattin
    Bas, Zeynep
    Sadikoglu, Murat
    Yagmur, Sultan
    Saglikoglu, Gulsen
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2016, 11 (07): : 6244 - 6255
  • [30] A Sensor for Detection of 4-nitrophenol Based on a Glassy Carbon Electrode Modified with a Reduced Graphene Oxide/Fe3O4 Nanoparticle Composite
    Cheng, Yongqiang
    Li, Yaohua
    Li, Dan
    Zhang, Bo
    Hao, Runfang
    Sang, Shengbo
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (08): : 7754 - 7764