Determination of Cotinine, 3′-Hydroxycotinine, and Their Glucuronides in Urine by Ultra-high Performance Liquid Chromatography

被引:4
|
作者
Shastri, Madhur D. [1 ]
Lu, Wenying [1 ]
Ferguson, Stuart G. [1 ,2 ]
Narkowicz, Christian K. [1 ]
Davies, Noel W. [3 ]
Jacobson, Glenn A. [1 ]
机构
[1] Univ Tasmania, Sch Med, Pharm, Fac Hlth, Hobart, Tas 7001, Australia
[2] Univ Tasmania, Sch Med, Med, Fac Hlth, Hobart, Tas 7001, Australia
[3] Univ Tasmania, Cent Sci Lab, Hobart, Tas 7001, Australia
基金
英国医学研究理事会;
关键词
Smoking; Cotinine; Glucuronide; 3 '-hydroxycotinine; Urine; Ultra-high performance liquid chromatography; TANDEM MASS-SPECTROMETRY; NICOTINE METABOLITE RATIO; SOLID-PHASE EXTRACTION; HUMAN LIVER-MICROSOMES; TRANSDERMAL NICOTINE; SMOKING-CESSATION; HUMAN PLASMA; LC-MS; SMOKERS; CYP2A6;
D O I
10.1080/00032719.2014.979363
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The measurement of the primary nicotine metabolites, cotinine and trans-3 '-hydroxycotinine, is a useful biomarker of nicotine exposure and metabolism genetics for smoking cessation research. Herein is described an ultra-high performance liquid chromatography-tandem mass spectrometry method for the determination of these primary nicotine metabolites in urine. Urine samples were diluted one hundred-fold with water and introduced into an ultra-high performance liquid chromatography triple quadrupole mass spectrometer using positive ion electrospray ionization with multiple reaction monitoring. Levels of urinary nicotine metabolites: cotinine, trans-3 '-hydroxycotinine, and their respective glucuronides were determined directly using deuterated internal standards and compared with indirect determination by enzymatic hydrolysis. The assay was applied to a community sample of smokers' urine (n=280). The assay demonstrated satisfactory performance (relative standard deviation of 1.6-6.5 percent at the 1000 nanograms per milliliter level and >98 percent recovery) suitable for application to smoking studies with a run time less than five minutes. The mean (min-max) levels of cotinine and cotinine-glucuronide were 968 (31-3831) and 976 (9-5607) nanograms per milliliter. The mean (min-max) levels of trans-3 '-hydroxycotinine and trans-3 '-hydroxycotinine-glucuronide were 3529 (13-21337) and 722 (0-4633) nanograms per milliliter. Direct determination of glucuronide metabolites was superior to indirect measurement using enzymatic hydrolysis, where there was evidence of loss of metabolites during sample preparation. A sensitive and selective ultra-high performance liquid chromatography-tandem mass spectrometry assay was successfully developed for the determination of cotinine, trans-3 '-hydroxycotinine, and their glucuronides in urine. The rapid and simple sample preparation makes this assay suitable for high throughput studies involving nicotine metabolism phenotype for both cytochrome P450 2A6 and uridine 5 '-diphospho-glucuronosyltransferase, smoking prevalence, and cessation studies.
引用
收藏
页码:1217 / 1233
页数:17
相关论文
共 50 条
  • [41] Determination of thiosulfate in human urine by high performance liquid chromatography
    Chwatko, Grazyna
    Bald, Edward
    TALANTA, 2009, 79 (02) : 229 - 234
  • [42] Determination of isoflavones in human urine by high performance liquid chromatography
    Wang, JJ
    Han, LH
    Zhu, LF
    Gao, YT
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2006, 34 (04) : 569 - 572
  • [43] Simultaneous determination of multiple isomeric hydroxylated polycyclic aromatic hydrocarbons in urine by using ultra-high performance liquid chromatography tandem mass spectrometry
    Hua, Liting
    Guo, Sai
    Wang, Yu
    Sun, Hongwen
    Zhao, Hongzhi
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2021, 1184
  • [44] Rapid Simultaneous Determination of Three Synthetic Cannabinoids in Urine and Plasma of Rats Using Ultra-High Performance Liquid Chromatography Tandem Mass Spectrometry
    Ke, Xing
    Tian, Yimei
    He, Dandan
    Mu, Pengqian
    Wan, Xuzhi
    Zhang, Lange
    Jia, Wei
    Wang, Qiao
    Fan, Yilei
    Zhang, Yu
    TOXICS, 2022, 10 (10)
  • [45] Feasibility of ultra-high performance liquid and gas chromatography coupled to mass spectrometry for accurate determination of primary and secondary phthalate metabolites in urine samples
    Herrero, Laura
    Calvarro, Sagrario
    Fernandez, Mario A.
    Eduardo Quintanilla-Lopez, Jesus
    Jose Gonzalez, Maria
    Gomara, Belen
    ANALYTICA CHIMICA ACTA, 2015, 853 : 625 - 636
  • [46] Simultaneous quantification of nicotine, cotinine, trans-3′-hydroxycotinine, norcotinine and mecamylamine in human urine by liquid chromatography-tandem mass spectrometry
    Scheidweiler, Karl B.
    Shakleya, Diaa M.
    Huestis, Marilyn A.
    CLINICA CHIMICA ACTA, 2012, 413 (11-12) : 978 - 984
  • [47] Determination of thyreostats in urine and thyroid gland by ultra high performance liquid chromatography tandem mass spectrometry
    Lohmus, Madis
    Kallaste, Kalle
    Le Bizec, Bruno
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (46) : 8080 - 8089
  • [48] Determination of Major Soybean Allergens by Ultra-high Performance Liquid Chromatography-Tandem Mass Spectrometry
    Li L.
    Huang W.
    Zhang J.
    Wang Y.
    Fu L.
    Han X.
    Chen Y.
    Chen, Ying (chenyingcaiq@163.com), 1600, Chinese Chamber of Commerce (41): : 316 - 324
  • [49] Determination of Isomaltooligosaccharides in Milk Powder by Ultra-High Performance Liquid Chromatography-Tandem Mass Spectrometry
    Jiao, Yanni
    Li, Fenghua
    Jiang, Dafeng
    Li, Wei
    Chen, Jindong
    ANALYTICAL LETTERS, 2016, 49 (04) : 458 - 466
  • [50] Determination and pharmacokinetics of engeletin in rat plasma by ultra-high performance liquid chromatography with tandem mass spectrometry
    Ye, Weijian
    Chen, Ruijie
    Sun, Wei
    Huang, Chengke
    Lin, Xixi
    Dong, Yaoyao
    Wen, Congcong
    Wang, Xianqin
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2017, 1060 : 144 - 149