Determination of Cotinine, 3′-Hydroxycotinine, and Their Glucuronides in Urine by Ultra-high Performance Liquid Chromatography

被引:4
|
作者
Shastri, Madhur D. [1 ]
Lu, Wenying [1 ]
Ferguson, Stuart G. [1 ,2 ]
Narkowicz, Christian K. [1 ]
Davies, Noel W. [3 ]
Jacobson, Glenn A. [1 ]
机构
[1] Univ Tasmania, Sch Med, Pharm, Fac Hlth, Hobart, Tas 7001, Australia
[2] Univ Tasmania, Sch Med, Med, Fac Hlth, Hobart, Tas 7001, Australia
[3] Univ Tasmania, Cent Sci Lab, Hobart, Tas 7001, Australia
基金
英国医学研究理事会;
关键词
Smoking; Cotinine; Glucuronide; 3 '-hydroxycotinine; Urine; Ultra-high performance liquid chromatography; TANDEM MASS-SPECTROMETRY; NICOTINE METABOLITE RATIO; SOLID-PHASE EXTRACTION; HUMAN LIVER-MICROSOMES; TRANSDERMAL NICOTINE; SMOKING-CESSATION; HUMAN PLASMA; LC-MS; SMOKERS; CYP2A6;
D O I
10.1080/00032719.2014.979363
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The measurement of the primary nicotine metabolites, cotinine and trans-3 '-hydroxycotinine, is a useful biomarker of nicotine exposure and metabolism genetics for smoking cessation research. Herein is described an ultra-high performance liquid chromatography-tandem mass spectrometry method for the determination of these primary nicotine metabolites in urine. Urine samples were diluted one hundred-fold with water and introduced into an ultra-high performance liquid chromatography triple quadrupole mass spectrometer using positive ion electrospray ionization with multiple reaction monitoring. Levels of urinary nicotine metabolites: cotinine, trans-3 '-hydroxycotinine, and their respective glucuronides were determined directly using deuterated internal standards and compared with indirect determination by enzymatic hydrolysis. The assay was applied to a community sample of smokers' urine (n=280). The assay demonstrated satisfactory performance (relative standard deviation of 1.6-6.5 percent at the 1000 nanograms per milliliter level and >98 percent recovery) suitable for application to smoking studies with a run time less than five minutes. The mean (min-max) levels of cotinine and cotinine-glucuronide were 968 (31-3831) and 976 (9-5607) nanograms per milliliter. The mean (min-max) levels of trans-3 '-hydroxycotinine and trans-3 '-hydroxycotinine-glucuronide were 3529 (13-21337) and 722 (0-4633) nanograms per milliliter. Direct determination of glucuronide metabolites was superior to indirect measurement using enzymatic hydrolysis, where there was evidence of loss of metabolites during sample preparation. A sensitive and selective ultra-high performance liquid chromatography-tandem mass spectrometry assay was successfully developed for the determination of cotinine, trans-3 '-hydroxycotinine, and their glucuronides in urine. The rapid and simple sample preparation makes this assay suitable for high throughput studies involving nicotine metabolism phenotype for both cytochrome P450 2A6 and uridine 5 '-diphospho-glucuronosyltransferase, smoking prevalence, and cessation studies.
引用
收藏
页码:1217 / 1233
页数:17
相关论文
共 50 条
  • [1] Determination of Cotinine in Human Urine by High-Performance Liquid Chromatography
    Wen, Yen-Hsia
    Yang, Pei-Shin
    Wu, Shihn-Sheng
    JOURNAL OF FOOD AND DRUG ANALYSIS, 2009, 17 (05) : 357 - 362
  • [2] SIMULTANEOUS DETERMINATION OF COTININE AND TRANS-3'-HYDROXYCOTININE IN HUMAN SERUM BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    PICHINI, S
    ALTIERI, I
    PACIFICI, R
    ROSA, M
    OTTAVIANI, G
    ZUCCARO, P
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 577 (02): : 358 - 361
  • [3] AUTOMATION OF A HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ASSAY FOR THE DETERMINATION OF NICOTINE, COTININE AND 3-HYDROXYCOTININE IN HUMAN URINE
    MOORE, J
    GREENWOOD, M
    SINCLAIR, N
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1990, 8 (8-12) : 1051 - 1054
  • [4] Plasma cotinine, 3′-hydroxycotinine, and their glucuronides in white and black smokers
    de Leon, J
    Diaz, FJ
    Rogers, T
    Browne, D
    Dinsmore, L
    Ghosheh, OA
    Dwoskin, LP
    Crooks, PA
    JOURNAL OF CLINICAL PSYCHOPHARMACOLOGY, 2003, 23 (02) : 209 - 211
  • [5] DETERMINATION OF CIS-3-HYDROXYCOTININE AND TRANS-3-HYDROXYCOTININE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    ODOHERTY, S
    REVANS, A
    SMITH, CL
    MCBRIDE, M
    COOKE, M
    JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1988, 11 (10): : 723 - 725
  • [6] Determination of Nucleotides in Infant Formula by Ultra-high Performance Liquid Chromatography
    Wang X.
    Shan Y.
    Wei X.
    Li W.
    E L.
    Jiang Y.
    Jiang, Yujun (yujun_jiang@163.com), 2021, Chinese Chamber of Commerce (42): : 254 - 262
  • [7] Cholesterol determination in foods: Comparison between high performance and ultra-high performance liquid chromatography
    Albuquerque, Tania Goncalves
    Oliveira, M. Beatriz P. P.
    Sanches-Silva, Ana
    Costa, Helena S.
    FOOD CHEMISTRY, 2016, 193 : 18 - 25
  • [9] Direct determination of tramadol glucuronides in human urine by high-performance liquid chromatography with fluorescence detection
    Overbeck, P
    Blaschke, G
    JOURNAL OF CHROMATOGRAPHY B, 1999, 732 (01): : 185 - 192
  • [10] Development and validation of ultra-high performance supercritical fluid chromatography method for determination of illegal dyes and comparison to ultra-high performance liquid chromatography method
    Khalikova, Maria A.
    Satinsky, Dalibor
    Solich, Petr
    Novakova, Lucie
    ANALYTICA CHIMICA ACTA, 2015, 874 : 84 - 96