A comparison of healthy human and swine articular cartilage dynamic indentation mechanics

被引:24
|
作者
Ronken, S. [1 ]
Arnold, M. P. [2 ]
Ardura Garcia, H. [3 ]
Jeger, A. [4 ]
Daniels, A. U. [1 ]
Wirz, D. [1 ,2 ]
机构
[1] Biozentrum Pharmazentrum, Lab Biomech & Biocalorimetry LOB2, CH-4056 Basel, Switzerland
[2] Kantonsspital Bruderholz, Bruderholz, Switzerland
[3] Univ Iberoamer, Dept Engn, Biomed Engn Sect, Mexico City, DF, Mexico
[4] Univ Basel Fac Med, Inst Sport & Sport Sci, Basel, Switzerland
关键词
Dynamic modulus; Energy dissipation; Human articular cartilage; Swine cartilage; Mechanical properties; BIOMECHANICAL PROPERTIES; UNCONFINED COMPRESSION; CONFINED COMPRESSION; OSTEOARTHRITIS; STIFFNESS; COLLAGEN; TRANSPLANTATION; THICKNESS; MODULUS; REPAIR;
D O I
10.1007/s10237-011-0338-7
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Articular cartilage is a multicomponent, poroviscoelastic tissue with nonlinear mechanical properties vital to its function. A consequent goal of repair or replacement of injured cartilage is to achieve mechanical properties in the repair tissue similar to healthy native cartilage. Since fresh healthy human articular cartilage (HC) is not readily available, we tested whether swine cartilage (SC) could serve as a suitable substitute for mechanical comparisons. To a first approximation, cartilage tissue and surgical substitutes can be evaluated mechanically as viscoelastic materials. Stiffness measurements (dynamic modulus, loss angle) are vital to function and are also a non-destructive means of evaluation. Since viscoelastic material stiffness is strongly strain rate dependent, stiffness was tested under different loading conditions related to function. Stiffness of healthy HC and SC specimens was determined and compared using two non-destructive, mm-scale indentation test modes: fast impact and slow sinusoidal deformation. Deformation resistance (dynamic modulus) and energy handling (loss angle) were determined. For equivalent anatomic locations, there was no difference in dynamic modulus. However, the HC loss angle was similar to 35% lower in fast impact and similar to 12% higher in slow sinusoidal mode. Differences seem attributable to age (young SC, older HC) but also to species anatomy and biology. Test mode-related differences in human-swine loss angle support use of multiple function-related test modes. Keeping loss angle differences in mind, swine specimens could serve as a standard of comparison for mechanical evaluation of e.g. engineered cartilage or synthetic repair materials.
引用
收藏
页码:631 / 639
页数:9
相关论文
共 50 条
  • [21] Indentation testing of human articular cartilage: Effects of probe tip geometry and indentation depth on intra-tissue strain
    Bae, WC
    Lewis, CW
    Levenston, ME
    Sah, RL
    [J]. JOURNAL OF BIOMECHANICS, 2006, 39 (06) : 1039 - 1047
  • [22] Repair of articular cartilage defects with acellular cartilage sheets in a swine model
    Xue, Jixin
    He, Aijuan
    Zhu, Yueqian
    Liu, Yu
    Li, Dan
    Yin, Zongqi
    Zhang, Wenjie
    Liu, Wei
    Cao, Yilin
    Zhou, Guangdong
    [J]. BIOMEDICAL MATERIALS, 2018, 13 (02)
  • [23] Post natal development of articular cartilage mechanics
    Van Turnhout, Mark C.
    Kranenbarg, Sander
    Van Leeuwen, Johan L.
    [J]. COMPARATIVE BIOCHEMISTRY AND PHYSIOLOGY A-MOLECULAR & INTEGRATIVE PHYSIOLOGY, 2009, 153A (02): : S116 - S116
  • [24] A COMPARISON OF DYNAMIC FORCE TRANSMITTING PROPERTIES OF SUBCHONDRAL BONE AND ARTICULAR CARTILAGE
    RADIN, EL
    PAUL, IL
    LOWY, M
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1970, A 52 (03): : 444 - &
  • [25] Viscoelastic modeling and quantitative experimental characterization of normal and osteoarthritic human articular cartilage using indentation
    Richard, F.
    Villars, M.
    Thibaud, S.
    [J]. JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2013, 24 : 41 - 52
  • [26] Influence of Aspect Ratios on the Creep Behaviour of Articular Cartilage in Indentation
    Spoon, C. E.
    Wayne, J. S.
    [J]. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2004, 7 (01) : 17 - 23
  • [27] MATHEMATICAL-ANALYSIS FOR INDENTATION TESTS OF ARTICULAR-CARTILAGE
    HAYES, WC
    HERRMANN, G
    MOCKROS, LF
    KEER, LM
    [J]. JOURNAL OF BIOMECHANICS, 1972, 5 (05) : 541 - &
  • [28] Effect of dermatan sulfate on the indentation and tensile properties of articular cartilage
    Hall, M. L.
    Krawczak, D. A.
    Simha, N. K.
    Lewis, J. L.
    [J]. OSTEOARTHRITIS AND CARTILAGE, 2009, 17 (05) : 655 - 661
  • [29] A new mechanical indentation framework for functional assessment of articular cartilage
    Arabshahi, Zohreh
    Afara, Isaac Oluwaseun
    Moody, Hayley Ruscoe
    Schrobback, Karsten
    Kashani, Jamal
    Fischer, Nadine
    Oloyede, Adekunle
    Klein, Travis Jacob
    [J]. JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2018, 81 : 83 - 94
  • [30] Application of an indentation sensor for the arthroscopic measurement of articular cartilage stiffness
    Kitta, Yuki
    Kiriyama, Yoshimori
    Harato, Kengo
    Kobayashi, Shu
    Niki, Yasuo
    Matsumoto, Morio
    Nakamura, Masaya
    Nagura, Takeo
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2022, 236 (04) : 566 - 572