Comparison of the intrinsic parameters (A, B, and S) of a forward osmosis membrane using pressurized and non-pressurized methods

被引:2
|
作者
Aziz, S. N. S. A. [1 ]
Rahman, A. F. H. A. [1 ]
Abu Seman, M. N. [1 ]
Hilal, N. [2 ]
机构
[1] Univ Malaysia Pahang, Fac Chem & Nat Resources Engn, Kuantan 26300, Pahang, Malaysia
[2] Swansea Univ, Coll Engn, CWATER, Fabian Way, Swansea SA1 8EN, W Glam, Wales
关键词
Intrinsic parameters; Forward osmosis; Single-stage method; Two-stage method; Concentration polarization; THIN-FILM-COMPOSITE; INTERNAL CONCENTRATION POLARIZATION; SUBSTRATE MEMBRANE; FLUX BEHAVIOR; REVERSE DRAW; PERFORMANCE; SOLUTE; TRANSPORT;
D O I
10.5004/dwt.2018.22811
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Generally, forward osmosis (FO) membrane performance is defined based on its intrinsic parameters, namely the water permeability (A), solute permeability (B), and structural parameter (S). This study was conducted to examine the performance of the commercial membrane NF2 in an FO system and to validate and compare the intrinsic value of A, B, and S obtained by single stage-stage and two-stage methods. The NF2 membrane was unable to demonstrate a good configuration for an FO membrane due to its membrane structure. Comparing the two different orientations in the single-stage method, it appears that both orientations display distinct sets of intrinsic values for the same membrane type. A comparison on the two-stage methods between the pressure-retarded osmosis -FO and reverse osmosis (RO)-FO methods reveals a new standard for the two-stage methods where higher fluxes must be produced from the first stage in order to attain an accurate value of S at the second stage. Additionally, the RO-FO methods were found to be not relevant for testing the ability of a membrane for FO application due to the hydraulic pressure involved during the compaction procedure. The two-stage method with proposed new standards can be the ideal testing procedure for the membrane in FO applications. This is because all the intrinsic values can be separately determined considering all the possible concentration polarization that might occur with both orientations compared with the attempts of fitting all possible values in the generated equations, as in single-stage methods.
引用
收藏
页码:14 / 23
页数:10
相关论文
共 31 条
  • [21] Comparison [3H]-flumazenil binding parameters in rat cortical membrane using different separation methods, filtration and centrifugation
    Ahmadi, Fatemeh
    Faizi, Mehrdad
    Tabatabai, Sayyed Abbas
    Beiki, Davood
    Shahhosseini, Soraya
    [J]. NUCLEAR MEDICINE AND BIOLOGY, 2013, 40 (07) : 896 - 900
  • [22] Determination of reference intervals and comparison of venous blood gas parameters using standard and non-standard collection methods in 24 cats
    Bachmann, Karin
    Kutter, Annette P. N.
    Schefer, Rahel Jud
    Marly-Voquer, Charlotte
    Sigrist, Nadja
    [J]. JOURNAL OF FELINE MEDICINE AND SURGERY, 2017, 19 (08) : 831 - 840
  • [23] Comparison of Bruch's membrane opening and scleral ring disc margin detection methods using DRI OCT Triton scan data
    Dong, Ying
    Yang, Qi
    Huang, Wei Chieh
    Reisman, Charles A.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [24] The use of archival bone marrow specimens in detecting B-cell non-Hodgkin's lymphomas using polymerase chain reaction methods
    Nagasaka, T
    Lai, R
    Chen, YY
    Chen, WG
    Arber, DA
    Chang, KL
    Weiss, LM
    [J]. LEUKEMIA & LYMPHOMA, 2000, 36 (3-4) : 347 - 352
  • [25] Comparison of glaucomatous from non-glaucomatous optic neuropathy using Bruch's membrane opening minimum rim width optical coherence tomography measurements
    Gosalia, Hirika
    Kumar, Karthik M.
    Karan, A. K.
    Saravanan, Veerappan R.
    Shah, Virna M.
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2023, 71 (08) : 3005 - 3009
  • [26] Simulation of quantum transport in double-gate MOSFETs using the non-equilibrium Green's function formalism in real-space: A comparison of four methods
    Sabry, Yasser M.
    Abdolkader, Tarek M.
    Farouk, Wael F.
    [J]. INTERNATIONAL JOURNAL OF NUMERICAL MODELLING-ELECTRONIC NETWORKS DEVICES AND FIELDS, 2011, 24 (04) : 322 - 334
  • [27] Blinded Clinical Evaluation for Dementia of Alzheimer's Type Classification Using FDG-PET: A Comparison Between Feature-Engineered and Non-Feature-Engineered Machine Learning Methods
    Ma, Da
    Yee, Evangeline
    Stocks, Jane K.
    Jenkins, Lisanne M.
    Popuri, Karteek
    Chausse, Guillaume
    Wang, Lei
    Probst, Stephan
    Beg, Mirza Faisal
    [J]. JOURNAL OF ALZHEIMERS DISEASE, 2021, 80 (02) : 715 - 726
  • [28] Commentary on !Farnell S, !Maxwell L, !Tan S, !Rhodes A and !Philips B (2005) temperature measurement:: a comparison of non-invasive methods used in adult critical care.: Journal of clinical nursing 14, 632-639
    Closs, SJ
    [J]. JOURNAL OF CLINICAL NURSING, 2005, 14 (08) : 1026 - 1027
  • [29] Commentary on !Farnell S, !Maxwell L, !Tan S, !Rhodes A and !Philips B (2005) temperature measurement:: a comparison of non-invasive methods used in adult critical care.: Journal of clinical nursing 14, 632-639 -: Response
    Farnell, S
    [J]. JOURNAL OF CLINICAL NURSING, 2005, 14 (08) : 1028 - 1028
  • [30] STEREOCHEMICALLY NON-RIGID SILANES, GERMANES, AND STANNANES .6. POLY(CYCLOPENTADIENYL)SILANES - COMPARISON OF THERMODYNAMIC PARAMETERS DERIVED FROM APPROXIMATE METHODS WITH THOSE OBTAINED USING FULL LINESHAPE ANALYSIS OF C-13 NUCLEAR MAGNETIC-RESONANCE DATA
    BONNY, A
    STOBART, SR
    [J]. JOURNAL OF THE CHEMICAL SOCIETY-DALTON TRANSACTIONS, 1980, (02): : 224 - 228