Effect of MLC leaf width and PTV margin on the treatment planning of intensity-modulated stereotactic radiosurgery or fractionated stereotactic radiotherapy

被引:2
|
作者
Chang, J [1 ]
Yenice, K [1 ]
Narayana, A [1 ]
机构
[1] Mem Sloan Kettering Canc Ctr, New York, NY 10021 USA
关键词
D O I
10.1118/1.1998363
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate the effect of MLC leaf width and PTV margin on intensity modulated radiosurgery (IMSRS) and radiostherapy (IMSRT) dose distributions. Method and Materials: Twelve patients previously treated with IMSRS or IMSRT were retrospectively planned with a 5mm or 3mm MLC leaf width and a 3mm or 2mm PTV margin using the already contoured CTV, critical structures and organs at risk (OARs). The same beam arrangement, planning parameters and plan selection criteria were used in each four plans for a given patient. Same target coverage was achieved by renormalizing each plan so that the prescription dose covered at least 99% of the PTV. Plan indexes — Dmax, Dmin, and Dmean, conformity index (CI), V70, V50, D95 and V95 were calculated from the dose‐volume histograms of PTV, normal tissue, or OARs. Ratios of plan indexes were computed and hypotheses tests were performed on the mean ratios to determine the significance of the relative changes. Results: The PTV was well covered for all plans. The PTV was 25% smaller when 2mm instead of 3mm PTV margin was used; CI of 3mm MLC was 7% lowered than that of 5mm MLC. The decrease of MLC leaf width had a similar effect as that of PTV margin in reducing V70 and V50 of the normal tissue and Dmean of brainstem by ∼10%. However, Dmean of optic nerve and chiasm was more sensitive to the change of PTV margin. Conclusion: For IMSRT, the combination of 5mm MLC and 2mm PTV margin is dosimetrically equal to that of 3mm MLC and 3mm PTV margin for both PTV coverage and normal tissue sparing. The use of 5mm MLC and 2mm PTV margin for IMSRS is problematic because V70 and V5 are ∼10% higher than that of 3mm MLC and 2mm PTV margin. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2087 / 2087
页数:1
相关论文
共 50 条
  • [41] The Effect of Multileaf Collimator Leaf Width on the Quality of Volumetric-Modulated Arc Therapy Stereotactic Radiosurgery Treatment Plans
    Laoui, S.
    Kuo, J. V.
    Al-Ghazi, M.
    Roa, D. E.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E682 - E683
  • [42] DOSIMETRIC COMPARISON OF INTENSITY-MODULATED STEREOTACTIC RADIOTHERAPY WITH OTHER STEREOTACTIC TECHNIQUES FOR LOCALLY RECURRENT NASOPHARYNGEAL CARCINOMA
    Kung, Shiris Wai Sum
    Wu, Vincent Wing Cheung
    Kam, Michael Koon Ming
    Leung, Sing Fai
    Yu, Brian Kwok Hung
    Ngai, Dennis Yuen Kan
    Wong, Simon Chun Fai
    Chan, Anthony Tak Cheung
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 79 (01): : 71 - 79
  • [43] Quality Assurance Comparison of Intensity Modulated Stereotactic Radiosurgery between Different Treatment Planning Systems
    Guo, F.
    Carlson, D.
    Chen, Z.
    Deng, J.
    Picone, J.
    Nath, R.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S867 - S867
  • [44] STEREOTACTIC RADIOTHERAPY OF INTRACRANIAL TUMORS: A COMPARISON OF INTENSITY-MODULATED RADIOTHERAPY AND DYNAMIC CONFORMAL ARC
    Wiggenraad, Ruud G. J.
    Petoukhova, Anna L.
    Versluis, Lia
    van Santvoort, Jan P. C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 74 (04): : 1018 - 1026
  • [45] Intensity-modulated radiotherapy of sacral chordoma - A case report and a comparison with stereotactic conformal radiotherapy
    Thilmann, C
    Schulz-Ertner, D
    Zabel, A
    Herfarth, KK
    Wannenmacher, M
    Debus, J
    ACTA ONCOLOGICA, 2002, 41 (04) : 395 - 399
  • [46] Impact of collimator leaf width on stereotactic radiosurgery and 3D conformal radiotherapy treatment plans
    Kubo, HD
    Wilder, RB
    Pappas, CTE
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 44 (04): : 937 - 945
  • [47] Integrating Serial Pathways in Radiotherapy Treatment Planning-impact on the Decision Making in Delivering Stereotactic Radiosurgery (SRS) vs. Fractionated Stereotactic Radiotherapy (FSRT)
    Butler, E.
    Hayman, A.
    Paulino, A. C.
    Blanco, A. I.
    Teh, B. S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S796 - S796
  • [48] Dosimetric study using different leaf-width MLCs for treatment planning of dynamic conformal arcs and intensity-modulated radiosurgery
    Jin, JY
    Yin, FF
    Ryu, S
    Ajlouni, M
    Kim, JH
    MEDICAL PHYSICS, 2005, 32 (02) : 405 - 411
  • [49] Impact of Cochlear Dose on Hearing Preservation following Stereotactic Radiosurgery and Fractionated Stereotactic Radiotherapy for the Treatment of Vestibular Schwannoma
    Chung, Lawrance K.
    Ung, Nolan
    Sheppard, John P.
    Thien Nguyen
    Lagman, Carlito
    Choy, Winward
    Tenn, Stephen
    Pouratian, Nader
    Lee, Percy
    Kaprealian, Tania
    Selch, Michael
    De Salles, Antonio
    Gopen, Quinton
    Yang, Isaac
    JOURNAL OF NEUROLOGICAL SURGERY PART B-SKULL BASE, 2018, 79 (04) : 335 - 342
  • [50] The Use of Jaw Tracking in Intensity Modulated and Volumetric Modulated Arc Radiotherapy for Spine Stereotactic Radiosurgery
    Chin, K.
    Wen, N.
    Huang, Y.
    Kim, J.
    Zhao, B.
    Siddiqui, S.
    Chetty, I.
    Ryu, S.
    MEDICAL PHYSICS, 2014, 41 (06) : 316 - 316