Gadolinium an alternative contrast agent for sialography in patients with iodine sensitivity

被引:10
|
作者
Williams, MD [1 ]
Moody, AB
Newlands, CA
Howlett, DC
机构
[1] Eastbourne Dist Gen Hosp, Dept Maxillofacial Surg, Eastbourne BN21 2UD, E Sussex, England
[2] Eastbourne Dist Gen Hosp, Dept Diagnost Imaging, Eastbourne BN21 2UD, E Sussex, England
关键词
sialography; gadolinum; iodine sensitivity;
D O I
10.1054/ijom.2002.0439
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The use of iodinated contrast material in radiography is contraindicated in patients with known iodine sensitivity and such patients may present a management dilemma. The successful use of gadolinium in contrast sialography is described.
引用
收藏
页码:651 / 652
页数:2
相关论文
共 50 条
  • [31] An evaluation of gadolinium polyoxornetalates as possible MRI contrast agent
    Feng, JH
    Li, XJ
    Pei, FK
    Sun, GY
    Zhang, X
    Liu, ML
    MAGNETIC RESONANCE IMAGING, 2002, 20 (05) : 407 - 412
  • [32] GADOLINIUM-DTPA AS INTRAVENOUS MRI CONTRAST AGENT
    STEINER, RE
    BRITISH JOURNAL OF RADIOLOGY, 1985, 58 (690): : 582 - 582
  • [33] Maternofetal Pharmacokinetics of a Gadolinium Chelate Contrast Agent in Mice
    Muehler, Matthias R.
    Clement, Olivier
    Salomon, Laurent J.
    Balvay, Daniel
    Autret, Gwennhael
    Vayssettes, Catherine
    Cuenod, Charles A.
    Siauve, Nathalie
    RADIOLOGY, 2011, 258 (02) : 455 - 460
  • [34] The Potential of Gadolinium Ascorbate Nanoparticles as a Safer Contrast Agent
    Dey, Ujjala
    Chattopadhyay, Arun
    JOURNAL OF PHYSICAL CHEMISTRY B, 2023, 127 (01): : 346 - 358
  • [35] Gadolinium as a CT contrast agent: Assessment in a porcine model
    Gierada, DS
    Bae, KT
    RADIOLOGY, 1999, 210 (03) : 829 - 834
  • [36] GADOLINIUM(III) TEXAPHYRIN - A NOVEL MRI CONTRAST AGENT
    SESSLER, JL
    MODY, TD
    HEMMI, GW
    LYNCH, V
    YOUNG, SW
    MILLER, RA
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1993, 115 (22) : 10368 - 10369
  • [37] Gadolinium Complexes as Contrast Agent for Cellular NMR Spectroscopy
    Sakol, Nat
    Egawa, Ayako
    Fujiwara, Toshimichi
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2020, 21 (11) : 1 - 17
  • [38] Gadolinium as a CT contrast agent: Assessment in rabbits model
    Choi, H
    Hwang, J
    Lee, S
    Chung, S
    Cho, K
    RADIOLOGY, 2000, 217 : 514 - 514
  • [39] Nursing experience of patients with leakage of the intravenous iodine contrast agent: A case report
    Leng, Xue
    Pu, Fang-fei
    Hu, Qin-rong
    ASIAN JOURNAL OF SURGERY, 2023, 46 (11) : 5076 - 5076
  • [40] Gadolinium- or iodine-based contrast media: which choice?
    Thomsen, Henrik S.
    ACTA RADIOLOGICA, 2014, 55 (07) : 771 - U7