Dynamic 1H-MRS for detection of 13C-labeled glucose metabolism in the human brain at 3T

被引:6
|
作者
Dehghani, Masoumeh [1 ,2 ]
Zhang, Steven [3 ]
Kumaragamage, Chathura [4 ]
Rosa-Neto, Pedro [5 ,6 ]
Near, Jamie [1 ,2 ]
机构
[1] Douglas Mental Hlth Univ Inst, Ctr Imagerie Cerebrale, 6875 LaSalle Blvd, Verdun, PQ H4H 1R3, Canada
[2] McGill Univ, Dept Psychiat, Montreal, PQ, Canada
[3] McGill Univ, Dept Neurosci, Montreal, PQ, Canada
[4] Yale Univ, Dept Radiol & Biomed Imaging, New Haven, CT USA
[5] McGill Univ, Res Ctr Studies AgiNG, Douglas Res Inst, Alzheimers Dis Res Unit,Translat Neuroimaging Lab, Montreal, PQ, Canada
[6] McGill Univ, Dept Neurol & Neurosurg, Psychiat & Pharmacol & Therapeut, Montreal, PQ, Canada
关键词
H-1; MRS; C-13; labeling; amino acid neurotransmitters; clinical scanner; glucose metabolism; human brain; MAGNETIC-RESONANCE-SPECTROSCOPY; C-13; NMR-SPECTROSCOPY; IN-VIVO; MRS; GLUTAMATE; INFUSION; OPTIMIZATION; SUPPRESSION; CYCLE;
D O I
10.1002/mrm.28188
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose In 2004, Boumezbeur et al proposed a simple yet powerful approach to detect the metabolism of C-13-enriched substrates in the brain. Their approach consisted of dynamic H-1-MRS, without a C-13 radiofrequency (RF) channel, and its successful application was demonstrated in monkeys. Since then, this promising method has yet to be applied rigorously in humans. In this study, we revisit the use of dynamic H-1-MRS to measure the metabolism of C-13-enriched substrates and demonstrate its application in the human brain. Methods In healthy participants, H-1-MRS data were acquired dynamically before and following a bolus infusion of [1-C-13] glucose. Data were acquired on a 3T clinical MRI scanner using a short-TE SPECIAL sequence, with regions of interest in both anterior and posterior cingulate cortex. Using simulated basis spectra to model signal changes in both C-12-bonded and C-13-coupled resonances, the acquired spectra were fit in LCModel to obtain labeling time courses for glutmate and glutamine at both C4 and C3 positions. Results Presence of the C-13 label was clearly detectable, owing to the pronounced effect of heteronuclear (C-13-H-1) scalar coupling on the observed H-1 spectra. A decrease in signal from C-12-bonded protons and an increase in signal from C-13-coupled protons were observed. The fractional enrichment of Glu-C4, (Glu+Gln)-C4, and (Glu+Gln)-C3 at 30 minutes following infusion of [1-C-13] glucose was similar in both regions: 11% to 13%, 9% to 12% and 3% to 5%, respectively. Conclusion These preliminary results confirm the feasibility of the use of dynamic H-1-MRS to monitor C-13 labeling in the human brain, without a C-13 RF channel.
引用
收藏
页码:1140 / 1151
页数:12
相关论文
共 50 条
  • [31] Human cervical lymphadenopathy:: evaluation with in vivo 1H-MRS at 1.5 T
    King, AD
    Yeung, DK
    Ahuja, AT
    Yuen, EHY
    Ho, SFM
    Tse, GMK
    van Hasselt, AC
    CLINICAL RADIOLOGY, 2005, 60 (05) : 592 - 598
  • [32] In Vivo Detection of Serine in the Human Brain by Proton Magnetic Resonance Spectroscopy (1H-MRS) at 7 Tesla
    Choi, Changho
    Dimitrov, Ivan
    Douglas, Deborah
    Zhao, Chenguang
    Hawesa, Halima
    Ghose, Subroto
    Tamminga, Carol A.
    MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (04) : 1042 - 1046
  • [33] Establishment of new approaches to understanding the brain glycogen metabolism-By NMR spectroscopic technique using 13C-labeled glucose and lactate
    Mizokawa, Hirokazu
    Kokubu, George
    Kobayashi, Youichi
    Kanamatsu, Tomoyuki
    NEUROSCIENCE RESEARCH, 2011, 71 : E413 - E413
  • [34] Unsupervised anomaly detection using generative adversarial networks in 1H-MRS of the brain
    Jang, Joon
    Lee, Hyeong Hun
    Park, Ji-Ae
    Kim, Hyeonjin
    Journal of Magnetic Resonance, 2021, 325
  • [35] Metabolic heterogeneity of the normal human brain: multivariate analysis of 1H MRS in vivo spectra acquired at 3T
    Agnieszka Skorupa
    Łukasz Boguszewicz
    Marek Kijonka
    Maria Sokół
    Metabolomics, 2017, 13
  • [36] Metabolic heterogeneity of the normal human brain: multivariate analysis of 1H MRS in vivo spectra acquired at 3T
    Skorupa, Agnieszka
    Boguszewicz, Lukasz
    Kijonka, Marek
    Sokol, Maria
    METABOLOMICS, 2017, 13 (04)
  • [37] Imaging of 13C-labeled glucose and sorbitol in bovine lens by 1H-detected 13C nuclear magnetic resonance spectroscopy
    Sawada, T
    Nakamura, J
    Nishida, Y
    Kani, K
    Okamoto, R
    Morikawa, S
    Inubushi, T
    MAGNETIC RESONANCE IMAGING, 2003, 21 (09) : 1029 - 1031
  • [38] PCA3 URINARY TEST VERSUS 3T 1H-MRS AND DCE-MRI IN THE DETECTION OF PROSTATE CANCER FOCI IN PATIENTS WITH BIOCHEMICAL ALTERATIONS
    Busetto, Gian Maria
    Panebianco, Valeria
    Sciarra, Alessandro
    De Berardinis, Ettore
    Tommaso, Biondi
    Danilo, Lisi
    Vincenzo, Gentile
    Franco, Di Silverio
    ANTICANCER RESEARCH, 2011, 31 (05) : 1845 - 1845
  • [39] Unsupervised anomaly detection using generative adversarial networks in 1H-MRS of the brain
    Jang, Joon
    Lee, Hyeong Hun
    Park, Ji-Ae
    Kim, Hyeonjin
    JOURNAL OF MAGNETIC RESONANCE, 2021, 325
  • [40] Dynamic Imaging of Glucose and Lactate Metabolism by 13C-MRS without Hyperpolarization
    Jeffrey R. Brender
    Shun Kishimoto
    Hellmut Merkle
    Galen Reed
    Ralph E. Hurd
    Albert P. Chen
    Jan Henrik Ardenkjaer-Larsen
    Jeeva Munasinghe
    Keita Saito
    Tomohiro Seki
    Nobu Oshima
    Kazutoshi Yamamoto
    Peter L. Choyke
    James Mitchell
    Murali C. Krishna
    Scientific Reports, 9