Oxidized regenerated cellulose for a clear thoracoscopic view: a single-centre randomized trial

被引:3
|
作者
Shimizu, Nahoko [1 ]
Tanaka, Yugo [1 ]
Kuroda, Sanae [1 ]
Nakamura, Hayate [1 ]
Matsumoto, Gaku [1 ]
Mitsui, Suguru [1 ]
Sakai, Shuto [1 ]
Minami, Kazuhiro [1 ]
Doi, Takefumi [1 ]
Hokka, Daisuke [1 ]
Maniwa, Yoshimasa [1 ]
机构
[1] Kobe Univ, Div Thorac Surg, Grad Sch Med, Kobe, Hyogo, Japan
关键词
Oxidized regenerated cellulose; Video-assisted thoracoscopic surgery; Randomized trial; ASSISTED THORACIC-SURGERY; OPEN THORACOTOMY; LOWER MORBIDITY; LOBECTOMY; CONVERSION;
D O I
10.1093/icvts/ivz271
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES: During video-assisted thoracoscopic surgery (VATS), blood oozing from the surface of the access port wound can hamper the surgical view. Although this oozing is difficult to prevent, it can be decreased by placing a wound edge protector with oxidized regenerated cellulose (ORC) on the surface of the access port wound, thereby improving the surgical outcomes and safety of VATS. METHODS: We conducted a prospective, single-centre, open-label, randomized clinical trial to evaluate the operative outcomes of VATS when using the ORC (ORC group) compared with operative outcomes without using the ORC (non-ORC group). The primary end point was interruption of the operation as a result of blood oozing from the surface of the access port wound. The secondary end points were the other intraoperative and postoperative outcomes. RESULTS: A total of 108 patients were divided into the ORC group (n = 54) and the non-ORC group (n = 54). Compared with the non-ORC group, the ORC group had fewer patients with an interruption in the operation (11.1% vs 51.8%; P < 0.001), less need for wound haemostasis of the access ports during wound closure (44.4% vs 72.2%; P = 0.003), similar rates of postoperative deaths and complications and a tendency for shorter operation times (149.3 vs 168.8 min, respectively; P = 0.083). CONCLUSION: The use of an ORC sheet around a wound edge protector for haemostasis can ensure a clear view during VATS.
引用
收藏
页码:346 / 352
页数:7
相关论文
共 50 条
  • [21] Calcitriol in Sepsis-A Single-Centre Randomised Control Trial
    Thampi, Siddhant Jeevan
    Basheer, Aneesh
    Thomas, Kurien
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (13)
  • [22] Thoracoscopic trans-mitral myectomy for hypertrophic obstructive cardiomyopathy: a retrospective single-centre study
    Wei, Peijian
    Ma, Jiexu
    Tan, Tong
    Zhu, Wei
    Yuan, Haiyun
    Zhuang, Jian
    Liu, Jian
    Guo, Huiming
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2023, 63 (04)
  • [23] Photo-oxidized bovine pericardium in congenital cardiac surgery: single-centre experience
    Baird, Christopher W.
    Myers, Patrick O.
    Piekarski, Breanna
    Borisuk, Michele
    Majeed, Amara
    Emani, Sitaram M.
    Sanders, Stephen P.
    Nathan, Meena
    del Nido, Pedro J.
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2017, 24 (02) : 240 - 244
  • [24] Hemostatic effect of oxidized regenerated cellulose vs. topical tranexamic acid in total knee arthroplasty-a prospective randomized controlled trial
    Li, Bowei
    Pan, Wenjie
    Ma, Jianbing
    Huang, Yuanchi
    FRONTIERS IN SURGERY, 2025, 11
  • [25] Prevention of de-novo adhesion formation after laparoscopic myomectomy: A randomized trial to evaluate the effectiveness of an oxidized regenerated cellulose absorbable barrier
    Mais, V
    Ajossa, S
    Piras, B
    Guerriero, S
    Marongiu, D
    Melis, GB
    HUMAN REPRODUCTION, 1995, 10 (12) : 3133 - 3135
  • [26] Coaching and/or education intervention for parents with overweight/obesity and their children: study protocol of a single-centre randomized controlled trial
    Karmali, Shazya
    Ng, Victor
    Battram, Danielle
    Burke, Shauna
    Morrow, Don
    Pearson, Erin S.
    Tucker, Patricia
    Mantler, Tara
    Cramp, Anita
    Petrella, Robert
    Irwin, Jennifer D.
    BMC PUBLIC HEALTH, 2019, 19 (1)
  • [27] Correction to: Efficacy and safety of remimazolam besylate versus propofol during hysteroscopy: single-centre randomized controlled trial
    Xiaoqiang Zhang
    Shuang Li
    Jing Liu
    BMC Anesthesiology, 21
  • [28] Efficiency of piezosurgery technique in miniscrew supported en-masse retraction: a single-centre, randomized controlled trial
    Tuncer, Nilufer Irem
    Arman-Ozcirpici, Ayca
    Oduncuoglu, Bahar Fusun
    Gocmen, Julide Sedef
    Kantarci, Alpdogan
    EUROPEAN JOURNAL OF ORTHODONTICS, 2017, 39 (06) : 586 - 594
  • [29] Does low-frequency vibration have an effect on aligner treatment? A single-centre, randomized controlled trial
    Lombardo, Luca
    Arreghini, Angela
    Ghislanzoni, Luis T. Huanca
    Siciliani, Giuseppe
    EUROPEAN JOURNAL OF ORTHODONTICS, 2019, 41 (04) : 434 - 443
  • [30] Coaching and/or education intervention for parents with overweight/obesity and their children: study protocol of a single-centre randomized controlled trial
    Shazya Karmali
    Victor Ng
    Danielle Battram
    Shauna Burke
    Don Morrow
    Erin S. Pearson
    Patricia Tucker
    Tara Mantler
    Anita Cramp
    Robert Petrella
    Jennifer D. Irwin
    BMC Public Health, 19