SEPARATE MAGNITUDE AND PHASE REGULARIZATION IN MRI WITH INCOMPLETE DATA: PRELIMINARY RESULTS

被引:12
|
作者
Zibetti, Marcelo V. W. [1 ]
De Pierro, Alvaro R. [2 ]
机构
[1] Univ Tecnol Fed Parana, Acad Dept Mech, CPGEI, Curitiba, Parana, Brazil
[2] Univ Estadual Campinas, Dept Appl Math, IMECC, BR-6065 Campinas, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
MRI; Compressed Sensing; Fast acquisitions; RECONSTRUCTION;
D O I
10.1109/ISBI.2010.5490069
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In Magnetic Resonance Imaging (MRI) studies, for clinical applications and for research as well, reduction of scanning time is an essential issue. This time reduction could be obtained by using fast acquisition sequences, such as EPI and spiral k-space trajectories, and by acquiring less data, this being possible based on the new sampling theories that gave rise to the so called Compressed Sampling (CS for short). However the main assumption for the application of CS to Fourier data is that magnitude and phase are both sparse in some given domain. This assumption is not always true for fast acquisition sequences because of the non-homogeneities of the main magnetic field. In this article we propose a new model for MRI with different regularization penalties for magnitude and phase. Magnitude regularization exploits the sparsity assumption on the signal and the suggested penalty for phase takes into account its smoothness. We show results of numerical experiments with simulated data.
引用
收藏
页码:736 / 739
页数:4
相关论文
共 50 条
  • [41] THE ROLE OF MRI IN THE EVALUATION OF A MIGRAINE POPULATION - PRELIMINARY DATA
    KAPLAN, R
    SOLOMON, G
    DIAMOND, S
    FREITAG, F
    HEADACHE, 1987, 27 (05): : 288 - 288
  • [42] THE ROLE OF MRI IN THE EVALUATION OF A MIGRAINE POPULATION - PRELIMINARY DATA
    KAPLAN, RD
    SOLOMON, GD
    DIAMOND, S
    FREITAG, FG
    HEADACHE, 1987, 27 (06): : 315 - 318
  • [43] Modeling Magnitude and Phase Neuronal Current MRI Signal Dependence on Echo Time
    Luo, Qingfei
    Gao, Jia-Hong
    MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (06) : 1832 - 1837
  • [44] COMPRESSED SENSING OF DIFFUSION MRI DATA USING SPATIAL REGULARIZATION AND POSITIVITY CONSTRAINTS
    Dolui, Sudipto
    Michailovich, Oleg V.
    Rathi, Yogesh
    2011 8TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2011, : 1597 - 1601
  • [45] Quality assurance of clinical MRI scanners using ACR MRI phantom: Preliminary results
    Chen, CC
    Wan, YL
    Wai, YY
    Liu, HL
    JOURNAL OF DIGITAL IMAGING, 2004, 17 (04) : 279 - 284
  • [46] Neonatal probabilistic models for brain, CSF and skull using T1-MRI data: preliminary results
    Kazemi, K.
    Ghadimi, S.
    Abrishami-Moghaddam, H.
    Grebe, R.
    Gondry-Jouet, C.
    Wallois, F.
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 3892 - +
  • [47] Quality Assurance of Clinical MRI Scanners Using ACR MRI Phantom: Preliminary Results
    Chien-Chuan Chen
    Yung-Liang Wan
    Yau-Yau Wai
    Ho-Ling Liu
    Journal of Digital Imaging, 2004, 17 : 279 - 284
  • [48] An Ice-Phase Microphysics Forward Model and Preliminary Results of Polarimetric Radar Data Assimilation
    Li, Xuanli
    Mecikalski, John R.
    Posselt, Derek
    MONTHLY WEATHER REVIEW, 2017, 145 (02) : 683 - 708
  • [49] VALUE OF SURFACE ANTENNAS IN VASCULAR MRI - PRELIMINARY-RESULTS
    GIRON, J
    SENAC, JP
    HERCOT, O
    ALAUX, A
    LAMARQUE, JL
    ANNALES DE RADIOLOGIE, 1987, 30 (03) : 169 - 176
  • [50] MRI findings in successful trachelectomy: Preliminary results in nine patients
    Petrow, PS
    Morice, P
    Cote, J
    Pomel, C
    Castaigne, D
    Duvillard, P
    RADIOLOGY, 2002, 225 : 128 - 128