First results from the online variable line spacing grating spectrometer at FLASH

被引:34
|
作者
Brenner, G. [1 ]
Kapitzki, S. [1 ]
Kuhlmann, M. [2 ]
Ploenjes, E. [1 ]
Noll, T. [3 ]
Siewert, F. [3 ]
Treusch, R. [1 ]
Tiedtke, K. [1 ]
Reininger, R. [4 ]
Roper, M. D. [5 ]
Bowler, M. A. [5 ]
Quinn, F. M. [5 ]
Feldhaus, J. [1 ]
机构
[1] Deutsch Elekt Synchrotron DESY, D-22607 Hamburg, Germany
[2] CELLS ALBA, E-08290 Barcelona, Spain
[3] Helmholtz Zentrum Berlin BESSY II, D-12489 Berlin, Germany
[4] Sci Answers & Solut, Madison, WI USA
[5] STEC Daresbury Lab, Warrington WA4 4AD, Cheshire, England
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 2011年 / 635卷
关键词
Free-electron laser; Spectrometers; Optical instruments; Diffraction gratings; Soft X-rays; Extreme ultraviolet; FREE-ELECTRON LASER; EXTREME-ULTRAVIOLET; RADIATION; VACUUM; BESSY; DESY;
D O I
10.1016/j.nima.2010.09.134
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A high resolution online grating spectrometer has been set up at the free electron laser in Hamburg FLASH at DESY in Hamburg. This new photon diagnostic device allows to parasitically measure the spectral distribution of the FEL laser pulses on a single shot basis and therefore gives complementary spectral and temporal pulse information for user experiments and FEL operation. The spectrometer combines a plane mirror and two plane variable line spacing (VLS) gratings and is installed at the non-monochromized beamline branch at FLASH. In contrast to a standard grating the blaze angle is optimized for the zero-order radiation transferred to the experimental stations, leaving approximately 1-10% intensity for recording the wavelength in the spectrometer. The detector, an intensified CCD camera imaging the dispersed beam on a Ce:YAG crystal, can follow the focal plane of the gratings covering a wavelength ranging from 6 to 60 nm. The resolving power of the spectrometer is expected to range from 500 to 8000 depending on the FEL wavelength. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:S99 / S103
页数:5
相关论文
共 50 条
  • [21] First Results from the Soho Ultraviolet Coronagraph Spectrometer
    J. L. Kohl
    G. Noci
    E. Antonucci
    G. Tondello
    M. C. E. Huber
    L. D. Gardner
    P. Nicolosi
    L. Strachan
    S. Fineschi
    J. C. Raymond
    M. Romoli
    D. Spadaro
    A. Panasyuk
    O. H. W. Siegmund
    C. Benna
    A. Ciaravella
    S. R. Cranmer
    S. Giordano
    M. Karovska
    R. Martin
    J. Michels
    A. Modigliani
    G. Naletto
    C. Pernechele
    G. Poletto
    P. L. Smith
    Solar Physics, 1997, 175 : 613 - 644
  • [22] High-resolution compact spectrometer based on a custom-printed varied-line-spacing concave blazed grating
    Chen, Jianwei
    Chen, Wang
    Zhang, Guodong
    Lin, Hui
    Chen, Shih-Chi
    OPTICS EXPRESS, 2017, 25 (11): : 12446 - 12454
  • [23] A variable fixed-focus constant optimization method for a variable-included-angle varied-line-spacing plane-grating monochromator
    Xue, Chaofan
    Xue, Lian
    Wu, Yanqing
    Wang, Yong
    Yang, Shumin
    Tai, Renzhong
    JOURNAL OF SYNCHROTRON RADIATION, 2019, 26 : 1192 - 1197
  • [24] First Results from the Modular Total Absorption Spectrometer at the HRIBF
    Fijalkowska, A.
    Karny, M.
    Rykaczewski, K. P.
    Wolinska-Cichocka, M.
    Grzywacz, R.
    Gross, C. J.
    Johnson, J. W.
    Rasco, B. C.
    Zganjar, E. F.
    Stracener, D. W.
    Jost, C.
    Goetz, K. C.
    Goans, R.
    Spejewski, E.
    Cartegni, L.
    Madurga, M.
    Miernik, K.
    Miller, D.
    Padgett, S. W.
    Paulauskas, S. V.
    Al-Shudifat, M.
    Hamilton, J. H.
    Ramayya, A. V.
    NUCLEAR DATA SHEETS, 2014, 120 : 26 - 29
  • [25] First QINS results from the TOF-spectrometer NEAT
    Lechner, RE
    Melzer, R
    Fitter, J
    PHYSICA B, 1996, 226 (1-3): : 86 - 91
  • [26] First results from a second generation toroidal electron spectrometer
    Broekman, L
    Tadich, A
    Huwald, E
    Riley, J
    Leckey, R
    Seyller, T
    Emtsev, K
    Ley, L
    JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 2005, 144 : 1001 - 1004
  • [27] FIRST RESULTS FROM THE MODULAR TOTAL ABSORPTION SPECTROMETER AT THE HRIBF
    Fijalkowska, A.
    Karny, M.
    Rykaczewski, K. P.
    Wolinska-Cichocka, M.
    Grzywacz, R.
    Gross, C. J.
    Johnson, J. W.
    Rasco, B. C.
    Zganjar, E. F.
    Stracener, D. W.
    Cartegni, L.
    Goetz, K. C.
    Goans, R.
    Jost, C.
    Madurga, M.
    Miernik, K.
    Miller, D.
    Padgett, S. W.
    Paulauskas, S. V.
    Al-Shudifat, M.
    Spejewski, E.
    Hamilton, J. H.
    Ramayya, A. V.
    ACTA PHYSICA POLONICA B, 2014, 45 (02): : 545 - 552
  • [28] Absolute, high-accuracy characterization of a variable line spacing grating for the European XFEL soft X-ray monochromator
    Vannoni, Maurizio
    Freijo-Martin, Idoia
    OPTICS EXPRESS, 2017, 25 (22): : 26519 - 26526
  • [29] First results of cloud retrieval from the Geostationary Environmental Monitoring Spectrometer
    Kim, Bo-Ram
    Kim, Gyuyeon
    Cho, Minjeong
    Choi, Yong-Sang
    Kim, Jhoon
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2024, 17 (02) : 453 - 470
  • [30] First results from the ATLAS muon spectrometer optical alignment system
    Amelung, C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 623 (01): : 388 - 390