Four-Dimensional MRI Using Three-Dimensional Radial Sampling with Respiratory Self-Gating to Characterize Temporal Phase-Resolved Respiratory Motion in the Abdomen

被引:74
|
作者
Deng, Zixin [1 ,2 ]
Pang, Jianing [1 ,3 ]
Yang, Wensha [4 ]
Yue, Yong [4 ]
Sharif, Behzad [1 ]
Tuli, Richard [4 ]
Li, Debiao [1 ,2 ]
Fraass, Benedick [4 ]
Fan, Zhaoyang [1 ]
机构
[1] Cedars Sinai Med Ctr, Dept Biomed Sci, Biomed Imaging Res Inst, Los Angeles, CA 90048 USA
[2] Univ Calif Los Angeles, Dept Bioengn, Los Angeles, CA USA
[3] Northwestern Univ, Dept Radiol & Biomed Engn, Chicago, IL 60611 USA
[4] Cedars Sinai Med Ctr, Dept Radiat Oncol, Los Angeles, CA 90048 USA
关键词
4D-MRI; 3D radial sampling; self-gating; respiratory motion; hysteresis; radiotherapy planning; HEART CORONARY MRA; CARDIAC CINE MRI; K-T BLAST; DYNAMIC MRI; RADIOTHERAPY; RECONSTRUCTION; SENSE; COMPENSATION; VARIABILITY; ANGIOGRAPHY;
D O I
10.1002/mrm.25753
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop a four-dimensional MRI (4D-MRI) technique to characterize the average respiratory tumor motion for abdominal radiotherapy planning. Methods: A continuous spoiled gradient echo sequence was implemented with 3D radial trajectory and 1D self-gating for respiratory motion detection. Data were retrospectively sorted into different respiratory phases based on their temporal locations within a respiratory cycle, and each phase was reconstructed by means of a self-calibrating CG-SENSE program. Motion phantom, healthy volunteer and patient studies were performed to validate the respiratory motion detected by the proposed method against that from a 2D real-time protocol. Results: The proposed method successfully visualized the respiratory motion in phantom and human subjects. The 4D-MRI and real-time 2D-MRI yielded comparable superior-inferior (SI) motion amplitudes (intraclass correlation = 0.935) with up-to one pixel mean absolute differences in SI displacements over 10 phases and high cross-correlation between phase-resolved displacements (phantom: 0.985; human: 0.937-0.985). Comparable anterior-posterior and left-right displacements of the tumor or gold fiducial between 4D and real-time 2D-MRI were also observed in the two patients, and the hysteresis effect was shown in their 3D trajectories. Conclusion: We demonstrated the feasibility of the proposed 4D-MRI technique to characterize abdominal respiratory motion, which may provide valuable information for radiotherapy planning. (C) 2015 Wiley Periodicals, Inc.
引用
收藏
页码:1574 / 1585
页数:12
相关论文
共 50 条
  • [1] Three-dimensional measurement of LV and RV dimensions using prospective self-gating for simultaneous compensation of cardiac and respiratory motion
    Robert Manka
    Peter Boesiger
    Martin Buehrer
    Sebastian Kozerke
    Journal of Cardiovascular Magnetic Resonance, 11 (Suppl 1)
  • [2] Three-Dimensional, In Vivo MRI With Self-Gating and Image Coregistration in the Mouse
    Nieman, Brian J.
    Szulc, Kamila U.
    Turnbull, Daniel H.
    MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (05) : 1148 - 1157
  • [3] Four-Dimensional (4D) Flow of the Whole Heart and Great Vessels Using Real-Time Respiratory Self-Gating
    Uribe, Sergio
    Beerbaum, Philipp
    Sorensen, Thomas Sangild
    Rasmusson, Allan
    Razavi, Reza
    Schaeffter, Tobias
    MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (04) : 984 - 992
  • [4] Four-Dimensional Whole Lung CT Using Retrospective Respiratory Gating Technique
    Sumikawa, H.
    Satoh, K.
    Yanagawa, M.
    Kikuyama, A.
    Tobino, K.
    Inoue, A.
    Honda, O.
    Yoshida, S.
    Johkoh, T.
    Tomiyama, N.
    Nakamura, H.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2009, 179
  • [5] Four-Dimensional Respiratory Motion-Resolved Whole Heart Coronary MR Angiography
    Piccini, Davide
    Feng, Li
    Bonanno, Gabriele
    Coppo, Simone
    Yerly, Jerome
    Lim, Ruth P.
    Schwitter, Juerg
    Sodickson, Daniel K.
    Otazo, Ricardo
    Stuber, Matthias
    MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (04) : 1473 - 1484
  • [6] Cardiac and Respiratory Self-Gating in Radial MRI Using an Adapted Singular Spectrum Analysis (SSA-FARY)
    Rosenzweig, Sebastian
    Scholand, Nick
    Holme, H. Christian M.
    Uecker, Martin
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2020, 39 (10) : 3029 - 3041
  • [7] Four-dimensional MRI using an internal respiratory surrogate derived by dimensionality reduction
    Uh, Jinsoo
    Khan, M. Ayaz
    Hua, Chiaho
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (21): : 7812 - 7832
  • [8] Four-dimensional radiotherapeutic dose calculation using biomechanical respiratory motion description
    Manescu, Petru
    Ladjal, Hamid
    Azencot, Joseph
    Beuve, Michael
    Testa, Etienne
    Shariat, Behzad
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2014, 9 (03) : 449 - 457
  • [9] Investigation of the dosimetric effect of respiratory motion using four-dimensional weighted radiotherapy
    Vandermeer, Aaron D.
    Alasti, Hamideh
    Cho, Young-Bin
    Norrlinger, Bern
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (15): : 4427 - 4448
  • [10] Four-dimensional radiotherapeutic dose calculation using biomechanical respiratory motion description
    Petru Manescu
    Hamid Ladjal
    Joseph Azencot
    Michael Beuve
    Etienne Testa
    Behzad Shariat
    International Journal of Computer Assisted Radiology and Surgery, 2014, 9 : 449 - 457