Shear wave elastography-based ultrasomics: differentiating malignant from benign focal liver lesions

被引:11
|
作者
Wang, Wei [1 ]
Zhang, Jian-Chao [1 ]
Tian, Wen-Shuo [1 ]
Chen, Li-Da [1 ]
Zheng, Qiao [2 ]
Hu, Hang-Tong [1 ]
Wu, Shan-Shan [1 ]
Guo, Yu [3 ]
Xie, Xiao-Yan [1 ]
Lu, Ming-De [1 ,4 ]
Kuang, Ming [1 ,4 ]
Liu, Long-Zhong [5 ]
Ruan, Si-Min [1 ]
机构
[1] Sun Yat Sen Univ, Ultras Artificial Intelligence X Lab, Inst Diagnost & Intervent Ultrasound, Dept Med Ultrason,Affiliated Hosp 1, 58 Zhongshan Rd 2, Guangzhou 510080, Peoples R China
[2] Sun Yat Sen Univ, Affiliated Hosp 1, Fetal Med Ctr, Dept Med Ultrason, Guangzhou, Peoples R China
[3] Sun Yat Sen Univ, Affiliated Hosp 1, Dept Gen Surg, Guangzhou, Peoples R China
[4] Sun Yat Sen Univ, Affiliated Hosp 1, Dept Hepatobiliary Surg, Guangzhou, Peoples R China
[5] Sun Yat Sen Univ, Canc Ctr, State Key Lab Oncol South China, Dept Ultrasound, 651 Dongfeng Dong Rd, Guangzhou 510060, Peoples R China
关键词
Ultrasonography; Machine learning; Elasticity imaging techniques; Liver; CONTRAST-ENHANCED ULTRASOUND; HEPATOCELLULAR-CARCINOMA; RADIOMICS; RECOMMENDATIONS; GUIDELINES; ACCURACY; FIBROSIS; MODEL;
D O I
10.1007/s00261-020-02614-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Ultrasomics is a radiomics technique that extracts high-throughput quantitative data from ultrasound imaging. The aim of this study was to differentiate malignant from benign focal liver lesions (FLLs) using two-dimensional shear wave elastography (2D-SWE)-based ultrasomics. Methods A total of 175 FLLs in 169 patients were prospectively analyzed. The study population was divided into a training cohort (n = 122) and a validation cohort (n = 53). The maxima, minima, mean, and standard deviation of 2D-SWE measurements were expressed in kilopascals (E-max,E-min,E-mean, andE(SD)). The ultrasonics technique was used to extract the features from the 2D-SWE images. Support vector machine was used to establish two prediction models: the ultrasomics score (ultrasomics features only) and the combined score (SWE measurements and ultrasomics features). The diagnostic performance of the models in differentiating FLLs was analyzed. Results A total of 1044 features were extracted and 15 features were selected. The AUC for the combined score, ultrasomics score,E-max,E-mean,E(min)andE(SD)were 0.94, 0.91, 0.92, 0.89, 0.67, and 0.89, respectively. The combined score had the best diagnostic performance. The sensitivity, specificity, PPV, NPV, +LR, LR of the combined score were 92.59%, 87.50%, 94.59%, 82.50%, 7.35%, and 0.09%, respectively. The decision curve analysis results showed that when the threshold probability was > 29%, the combined score showed improved benefits for patients compared to using the ultrasomics score and 2D-SWE measurements. Conclusion The results of this study demonstrated that the combined score had good diagnostic accuracy in differentiating malignant from benign FLLs.
引用
收藏
页码:237 / 248
页数:12
相关论文
共 50 条
  • [21] Combined Shear Wave Elastography and EU TIRADS in Differentiating Malignant and Benign Thyroid Nodules
    Chambara, Nonhlanhla
    Lo, Xina
    Chow, Tom Chi Man
    Lai, Carol Man Sze
    Liu, Shirley Yuk Wah
    Ying, Michael
    [J]. CANCERS, 2022, 14 (22)
  • [22] Evaluation of Multiparametric Shear Wave Elastography Indices in Malignant and Benign Breast Lesions
    Sanli, Deniz Esin Tekcan
    Yildirim, Duzgun
    Kandemirli, Sedat Giray
    Sanli, Ahmet Necati
    Aribal, Erkin
    [J]. ACADEMIC RADIOLOGY, 2022, 29 : S50 - S61
  • [23] Shear wave versus strain elastography in the differentiation of benign and malignant breast lesions
    Guruf, Aykut
    Ozturk, Mesut
    Bayrak, Ilkay Koray
    Polat, Ahmet Veysel
    [J]. TURKISH JOURNAL OF MEDICAL SCIENCES, 2019, 49 (05) : 1509 - 1517
  • [24] The value of contrast-enhanced ultrasound versus shear wave elastography in differentiating benign and malignant superficial lymph node lesions
    Cai, Huahai
    Liu, Shuyu
    [J]. AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH, 2021, 13 (10): : 11625 - 11631
  • [25] The Predictive Value of Transthoracic Shear-Wave Ultrasound Elastography in Differentiating Benign from Malignant Lung Tumors
    Kuo, Y.
    Chen, Y.
    Shih, J.
    Wang, H.
    Wu, H.
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2019, 199
  • [26] The role of endoscopic ultrasound elastography in differentiating focal liver lesions
    Papaefthymiou, Apostolis
    Doulberis, Michael
    Papadopoulos, Vassilios
    Tsiopoulos, Fotis
    Kapsoritakis, Andreas
    Potamianos, Spyros
    Kountouras, Jannis
    [J]. EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2020, 32 (10) : 1408 - 1408
  • [27] Shear wave elastography for characterization of focal liver lesions in alcohol-related liver disease
    Testino, Gianni
    [J]. MINERVA GASTROENTEROLOGY, 2022, 68 (02): : 231 - 232
  • [28] Shear wave elastography in differentiating between benign and malignant cervical lymph nodes in patients with oral carcinoma
    Sasaki, Yoshihiko
    Ogura, Ichiro
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2019, 48 (06)
  • [29] Evaluation of 2D-Shear Wave Elastography for Characterisation of Focal Liver Lesions
    Gerber, Ludmila
    Fitting, Daniel
    Srikantharajah, Kajana
    Weiler, Nina
    Kyriakidou, Georgia
    Bojunga, Joerg
    Schulze, Falko
    Bone, Dimitra
    Zeuzem, Stefan
    Friedrich-Rust, Mireen
    [J]. JOURNAL OF GASTROINTESTINAL AND LIVER DISEASES, 2017, 26 (03) : 283 - 290
  • [30] Clinical value of contrast-enhanced ultrasound in differentiating benign and malignant focal liver lesions
    Jinfeng Xu
    Ying Wu
    Fajin Dong
    Yi Xiong
    Qihui Peng
    Mingxing Xie
    [J]. Journal of Huazhong University of Science and Technology [Medical Sciences], 2007, 27 : 703 - 705