Preliminary Clinical Results: An Analyzing Tool for 2D Optical Imaging in Detection of Active Inflammation in Rheumatoid Arthritis

被引:1
|
作者
Nasirudin, Radin Adi Aizudin Bin Radin [1 ]
Meier, Reinhard [1 ]
Ahari, Carmen [1 ]
Sievert, Matti [1 ]
Fiebich, Martin [2 ]
Rummeny, Ernst J. [1 ]
Noel, Peter B. [1 ]
机构
[1] Tech Univ Munich, Dept Radiol, Munich, Germany
[2] Univ Appl Sci Giessen Friedberg, Inst Med Phys & Radiat Protect, Giessen, Germany
关键词
Optical Imaging; Rheumatoid Arthritis; Perfusion; Interface;
D O I
10.1117/12.878021
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Optical imaging (OI) is a relatively new method in detecting active inflammation of hand joints of patients suffering from rheumatoid arthritis (RA). With the high number of people affected by this disease especially in western countries, the availability of OI as an early diagnostic imaging method is clinically highly relevant. In this paper, we present a newly in-house developed OI analyzing tool and a clinical evaluation study. Our analyzing tool extends the capability of existing OI tools. We include many features in the tool, such as region-based image analysis, hyper perfusion curve analysis, and multi-modality image fusion to aid clinicians in localizing and determining the intensity of inflammation in joints. Additionally, image data management options, such as the full integration of PACS/RIS, are included. In our clinical study we demonstrate how OI facilitates the detection of active inflammation in rheumatoid arthritis. The preliminary clinical results indicate a sensitivity of 43.5%, a specificity of 80.3%, an accuracy of 65.7%, a positive predictive value of 76.6%, and a negative predictive value of 64.9% in relation to clinical results from MRI. The accuracy of inflammation detection serves as evidence to the potential of OI as a useful imaging modality for early detection of active inflammation in patients with rheumatoid arthritis. With our in-house developed tool we extend the usefulness of OI imaging in the clinical arena. Overall, we show that OI is a fast, inexpensive, non-invasive and non-ionizing yet highly sensitive and accurate imaging modality.
引用
收藏
页数:6
相关论文
共 33 条
  • [31] 2D soot volume fraction imaging in an ethylene diffusion flame by two-color laser-induced incandescence (2C-LII) technique and comparison with results from other optical diagnostics
    De Iuliis, S.
    Migliorini, F.
    Cignoli, F.
    Zizak, G.
    PROCEEDINGS OF THE COMBUSTION INSTITUTE, 2007, 31 : 869 - 876
  • [32] Impact of Body Mass Index on Clinical Responses of Novel Subcutaneous Infliximab (CT-P13 SC) in Patients with Active Rheumatoid Arthritis: 1-Year Results from a Part 2 of Phase I/III Randomized Controlled Trial
    Yoo, DaeHyun
    Westhovens, Rene
    Wiland, Piotr
    Zawadzki, Marek
    Ivanova, Delina
    Kasay, Alfredo Berrocal
    Chalouhi, Elias
    Balazs, Eva
    Lee, SangJoon
    Kim, SungHyun
    Han, Noori
    Jung, YooBin
    ARTHRITIS & RHEUMATOLOGY, 2020, 72
  • [33] IMPACTS OF BODY MASS INDEX ON CLINICAL RESPONSE OF NOVEL SUBCUTANEOUS INFLIXIMAB (CT-P13 SC) IN PATIENTS WITH ACTIVE RHEUMATOID ARTHRITIS: 1-YEAR RESULTS FROM A PART 2 OF PHASE I/III RANDOMIZED CONTROLLED TRIAL
    Yoo, D.
    Westhovens, R.
    Wiland, P.
    Zawadzki, M.
    Ivanova, D.
    Berrocal, A.
    Chalouhi, E.
    Balazs, E.
    Shevchuk, S.
    Lee, S. J.
    Kim, S. H.
    Han, N.
    Jung, Y.
    ANNALS OF THE RHEUMATIC DISEASES, 2020, 79 : 307 - 308