Further developments in an ac-based capacitance tomography system

被引:54
|
作者
Yang, WQ [1 ]
机构
[1] Univ Manchester, Inst Sci & Technol, Dept Elect Engn & Elect, Manchester M60 1QD, Lancs, England
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2001年 / 72卷 / 10期
关键词
D O I
10.1063/1.1403012
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An ac-based electrical capacitance tomography (ECT) system has been developed at UMIST, with sinusoidal excitation and phase-sensitive demodulation (PSD). In this article the overall system design is briefly described and then discussed in detail are the key design features, needed to achieve a high signal-to-noise ratio and a high data acquisition rate, including transient process analysis of the first stage, design of an analog Butterworth low-pass filter and optimization of the data acquisition process. The experiments show that the ac-based system has signal variance 19 times better than the previous design, the charge/discharge ECT system, and that a data acquisition rate of 140 frames per second is achieved for a 12-electrode system. (C) 2001 American Institute of Physics.
引用
收藏
页码:3902 / 3907
页数:6
相关论文
共 50 条
  • [42] Electrical capacitance tomography system for industrial applications
    Rerkratn, Apinai
    Yossontiku, Chanrit
    Lertpakdee, Thanakorn
    Chitsakul, Kitiphol
    Sangworasil, Manas
    IMECS 2006: INTERNATIONAL MULTICONFERENCE OF ENGINEERS AND COMPUTER SCIENTISTS, 2006, : 558 - +
  • [43] Development of a Portable Electrical Capacitance Tomography System
    Tang, Shuo
    Liang, Yung C.
    Tien, David
    Wang, Chi-Hwa
    IECON 2011: 37TH ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2011, : 2634 - 2638
  • [44] Design of Electrical Capacitance Tomography Hardware System
    Cao, Haiyan
    Duan, Xuemei
    Wang, Huaxiang
    MATERIALS PROCESSING AND MANUFACTURING III, PTS 1-4, 2013, 753-755 : 2311 - +
  • [45] Practical system design for electrical capacitance tomography
    Lu, Geng
    Peng, Li-Hui
    Yao, Dan-Ya
    Zhang, Bao-Fen
    Jiliang Xuebao/Acta Metrologica Sinica, 2004, 25 (03):
  • [46] Latest development of capacitance process tomography system
    Wang, Huaxiang
    Yang, Wiqiang
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2000, 21 (01): : 4 - 7
  • [47] A Dual Enhancement Switching Technology for Vacuum Circuit Breakers in Various AC-Based Operational Environments
    Eliyan, Tamer
    Al-Gahtani, Saad F.
    Elbarbary, Z. M. S.
    Wadie, Fady
    IEEE ACCESS, 2024, 12 : 156823 - 156836
  • [48] Recent developments in the solution of the forward problem in capacitance tomography and implications for iterative reconstruction
    Spink, D.M.
    Noras, J.M.
    Nondestructive Testing and Evaluation, 1998, 14 (03): : 115 - 142
  • [49] Hardware design and system calibration for electrical capacitance tomography system
    Deyun Chen
    Wenming Tang
    Lili Wang
    Xiaoyang Yu
    2007 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION, VOLS I-V, CONFERENCE PROCEEDINGS, 2007, : 3088 - 3093
  • [50] Analysis of performance and capacitance sensitivity distributions of sensor for electrical capacitance tomography system
    Sun, Liquan
    Chen, Deyun
    Zheng, Guibin
    WCICA 2006: SIXTH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION, VOLS 1-12, CONFERENCE PROCEEDINGS, 2006, : 4977 - +