Performance enhancements of compound semiconductor radiation detectors using digital pulse processing techniques

被引:24
|
作者
Abbene, L. [1 ]
Gerardi, G. [1 ]
机构
[1] Univ Palermo, Dipartimento Fis, I-90128 Palermo, Italy
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 2011年 / 654卷 / 01期
关键词
Compound semiconductors; CdTe detectors; X-ray and gamma ray spectroscopy; Digital pulse processing; Pulse height analysis; Pulse shape analysis; X-RAY SPECTROSCOPY; CDTE DETECTOR; GAMMA; RESOLUTION; MAMMOGRAPHY; PROGRESS;
D O I
10.1016/j.nima.2011.06.107
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The potential benefits of using compound semiconductors for X-ray and gamma ray spectroscopy are already well known. Radiation detectors based on high atomic number and wide band gap compound semiconductors show high detection efficiency and good spectroscopic performance even at room temperature. Despite these appealing properties, incomplete charge collection is a critical issue. Generally, incomplete charge collection, mainly due to the poor transport properties of the holes, produces energy resolution worsening and the well known hole tailing in the measured spectra. In this work, we present a digital pulse processing (DPP) system for high resolution spectroscopy with compound semiconductor radiation detectors. The DPP method, implemented on a PC platform, performs a height and shape analysis of the detector pulses (preamplifier output pulses), digitized by a 14-bit, 100 MHz ADC. Fast and slow shaping, automatic pole-zero adjustment, baseline restoration and pile-up rejection allow precise pulse height measurements both at low and high counting rate environments. Pulse shape analysis techniques (pulse shape discrimination, linear and nonlinear pulse shape corrections) to compensate for incomplete charge collection were also implemented. The results of spectroscopic measurements on a planar CdTe detector show the high potentialities of the system, obtaining low tailing in the measured spectra and energy resolution quite close to the theoretical limit. High-rate measurements (up to 820 kcps) exhibit the excellent performance of the pulse height analysis and the benefits of pulse shape techniques for peak pile-up reduction in the measured spectra. This work was carried out in the framework of the development of portable X-ray spectrometers for both laboratory research and medical applications. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:340 / 348
页数:9
相关论文
共 50 条
  • [21] Theoretical framework for mapping pulse shapes in semiconductor radiation detectors
    Safeguards Sci. and Technology Group, NIS-5, Mail Stop E540, Los Alamos N., Los Alamos, NM 87545, United States
    Nucl Instrum Methods Phys Res Sect A, 1 (72-80):
  • [22] Theoretical framework for mapping pulse shapes in semiconductor radiation detectors
    Prettyman, TH
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 428 (01): : 72 - 80
  • [23] Portable radiation spectrometer using low power digital pulse processing
    Jordanov, VT
    Hall, DL
    Kastner, M
    Woodward, GH
    Zakrzewski, RA
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 375 - 377
  • [24] Digital signal processing techniques for HPGe detectors operation
    Riboldi, Stefano
    Cattadori, Carla
    D'Andrea, Valerio
    Benato, Giovanni
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [25] Digital pulse timing with semiconductor gamma-ray detectors using a wavelet transform technique
    Nakhostin, M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (10):
  • [26] Development of semiconductor radiation detectors using GaN
    Inaba, Kagemitsu
    Hida, Kosuke
    Toyoda, Kohei
    Nishizawa, Junichi
    Takagi, Katsuyuki
    Kase, Hiroki
    Aoki, Toru
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS XXVI, 2024, 13151
  • [27] Pulse-height loss in the signal readout circuit of compound semiconductor detectors
    Nakhostin, M.
    Hitomi, K.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 893 : 146 - 150
  • [28] Digital pulse processing for NaI(T1) detectors
    Di Fulvio, A.
    Shin, T. H.
    Hamel, M. C.
    Pozzi, S. A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 806 : 169 - 174
  • [29] PULSE SLIMMING IN MAGNETIC RECORDING USING DIGITAL SIGNAL-PROCESSING TECHNIQUES
    DAVEY, PJ
    DONNELLY, T
    MAPPS, DJ
    MICROPROCESSING AND MICROPROGRAMMING, 1993, 37 (1-5): : 73 - 76
  • [30] Thunderstorm ground enhancements in Finland: observations using spectroscopic radiation detectors
    Leppanen, Ari-Pekka
    Perajarvi, Kari
    Paatero, Jussi
    Joutsenvaara, Jari
    Hannula, Antti
    Hepoaho, Arttu
    Holm, Philip
    Ilander, Tarja
    Karkkainen, Jouni
    ACTA GEOPHYSICA, 2024, : 2955 - 2970