Noninvasive structural and microvascular anatomy of oral mucosae using handheld optical coherence tomography

被引:31
|
作者
Tsai, Meng-Tsan [1 ,2 ,3 ,4 ]
Chen, Yingdan [2 ,3 ,5 ]
Lee, Cheng-Yu [1 ]
Huang, Bo-Huei [1 ]
Nguyen Hoang Trung [1 ]
Lee, Ya-Ju [6 ]
Wang, Yen-Li [7 ,8 ]
机构
[1] Chang Gung Univ, Dept Elect Engn, Taoyuan 33302, Taiwan
[2] Chang Gung Univ, Inst Radiol Res, Med Imaging Res Ctr, Taoyuan 33302, Taiwan
[3] Chang Gung Mem Hosp Linkou, Taoyuan 33302, Taiwan
[4] Chang Gung Mem Hosp, Dept Dermatol, Linkou 33305, Taiwan
[5] Zhejiang Gongshang Univ, Sch Informat & Elect Engn, Hangzhou 31108, Zhejiang, Peoples R China
[6] Natl Taiwan Normal Univ, Inst Electroopt Sci & Technol, Taipei 11677, Taiwan
[7] Chang Gung Mem Hosp, Dept Periodont, Taoyuan 33378, Taiwan
[8] Chang Gung Univ, Coll Med, Taoyuan 33378, Taiwan
来源
BIOMEDICAL OPTICS EXPRESS | 2017年 / 8卷 / 11期
关键词
SQUAMOUS-CELL CARCINOMA; SWEPT-SOURCE; TUMOR ANGIOGENESIS; CAVITY; MICROCIRCULATION; DIAGNOSIS; MICROSCOPY;
D O I
10.1364/BOE.8.005001
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this study, we demonstrated the feasibility of using a handheld optical coherence tomography (OCT) for in vivo visualizations of the microstructural and microvascular features of various oral mucosal types. To scan arbitrary locations of the oral mucosa, a scanning probe was developed, composed of a probe body fabricated by a 3D printer, miniaturized two-axis galvanometer, relay lenses, and reflective prism. With a 3D printing technique, the probe weight and the system volume were greatly reduced, enabling the effective improvement of imaging artifacts from unconscious motion and system complexity. Additionally, in our design, the distal end of the probe can be switched to fit various oral conditions, and the optical parameters of the probe, such as the transverse resolution, working distance, and probe length can be easily varied. The results showed that the epithelium and lamina propria layers, as well as the fungiform papilla and salivary gland, were differentiated. Moreover, various microcirculation features at different mucosal sites were identified that are potentially effective indicators for the diagnosis of premalignant lesions. The demonstrated results indicate that the developed OCT system is a promising tool for noninvasive imaging of oral mucosae. (C) 2017 Optical Society of America
引用
收藏
页码:5001 / 5012
页数:12
相关论文
共 50 条
  • [41] Optical coherence tomography of small intestine allograft biopsies using a handheld surgical probe
    Jelly, Evan T.
    Kwun, Jean
    Schmitz, Robin
    Farris, Alton B.
    Steelman, Zachary A.
    Sudan, Debra L.
    Knechtle, Stuart J.
    Wax, Adam
    JOURNAL OF BIOMEDICAL OPTICS, 2021, 26 (09)
  • [42] Advances in oral cancer detection using optical coherence tomography
    Jung, WG
    Zhang, J
    Chung, JR
    Wilder-Smith, P
    Brenner, M
    Nelson, JS
    Chen, ZP
    IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2005, 11 (04) : 811 - 817
  • [43] Imaging of Oral Pathological Tissue using Optical Coherence Tomography
    Canjau, Silvana
    Todea, Carmen
    Sinescu, Cosmin
    Duma, Virgil-Florin
    Topala, Florin I.
    Podoleanu, Adrian Gh.
    FIFTH INTERNATIONAL CONFERENCE ON LASERS IN MEDICINE: BIOTECHNOLOGIES INTEGRATED IN DAILY MEDICINE, 2014, 8925
  • [44] Prognosis of radiosensitivity of oral mucosa using optical coherence tomography
    Gladkova, N.
    Maslennikova, A.
    Balalaeva, I.
    Gelikonov, G.
    Feldchtein, F.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S33 - S33
  • [45] Evaluation of oral vascular anomalies using optical coherence tomography
    Ozawa, Nobuyoshi
    Sumi, Yasunori
    Chong, Changho
    Kurabayashi, Tohru
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2009, 47 (08): : 622 - 626
  • [46] Feasibility and Repeatability of Handheld Optical Coherence Tomography in Children With Craniosynostosis
    Rufai, Sohaib R.
    Bowman, Richard
    Bunce, Catey
    Panteli, Vasiliki
    McLean, Rebecca J.
    Teli, Seema
    Gottlob, Irene
    Thomas, Mervyn G.
    Jeelani, Noor Ul Owase
    Proudlock, Frank A.
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2021, 10 (08):
  • [47] A handheld microscope integrating photoacoustic microscopy and optical coherence tomography
    Qin, Wei
    Chen, Qian
    Xi, Lei
    BIOMEDICAL OPTICS EXPRESS, 2018, 9 (05): : 2205 - 2213
  • [48] Handheld Optical Coherence Tomography Scanner for Primary Care Diagnostics
    Jung, Woonggyu
    Kim, Jeehyun
    Jeon, Mansik
    Chaney, Eric J.
    Stewart, Charles N.
    Boppart, Stephen A.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2011, 58 (03) : 741 - 744
  • [49] A Handheld Optical Coherence Tomography System for Cosmetic Medicine Research
    Cheng, Chih-Ming
    Chang, Yu-Fen
    Chiang, Hung-Chih
    Chang, Chir-Weei
    BIOPHYSICAL JOURNAL, 2018, 114 (03) : 176A - 176A
  • [50] Improved feasibility of handheld optical coherence tomography in children with craniosynostosis
    Rufai, Sohaib R.
    Panteli, Vasiliki
    Henderson, Robert H.
    Bunce, Catey
    Gottlob, Irene
    Thomas, Mervyn G.
    Proudlock, Frank A.
    Bowman, Richard
    Jeelani, Noor ul Owase
    EYE, 2024, 38 (14) : 2829 - 2830