Distribution of air-water annular flow in a header of a parallel flow heat exchanger

被引:64
|
作者
Kim, Nae-Hyun [1 ]
Han, Sung-Pil [1 ]
机构
[1] Univ Incheon, Dept Mech Engn, Inchon 402749, South Korea
关键词
flow distribution; parallel flow heat exchanger; air water flow; header; annular flow;
D O I
10.1016/j.ijheatmasstransfer.2007.05.028
中图分类号
O414.1 [热力学];
学科分类号
摘要
The air and water flow distribution are experimentally studied for a heat exchanger composed of round headers and 10 flat tubes. The effects of tube protrusion depth as well as header mass flux, and quality are investigated, and the results are compared with previous 30 channel data. The flow at the header inlet is annular. For the downward flow configuration, water flow distribution is significantly affected by tube protrusion depth. For flush-mounted geometry, significant portion of water flows through frontal part of the header. As the protrusion depth increases, more water is forced to rear part of the header. The effect of header mass flux or quality is qualitatively the same as that of the protrusion depth. For the upward flow configuration, however, significant portion of water flows through rear part of the header. The effect of protrusion depth is the same as that of the downward flow. However, the effect of header mass flux or quality is opposite to the downward flow case. Compared with the previous 30 channel configuration, the present 10 channel configuration yields better flow distribution. Possible explanation is provided from flow visualization results. (C) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:977 / 992
页数:16
相关论文
共 50 条
  • [1] EFFECT OF INLET CONFIGURATION ON DISTRIBUTION OF AIR-WATER ANNULAR FLOW IN A HEADER OF A PARALLEL FLOW HEAT EXCHANGER
    Kim, N. H.
    Byun, H. W.
    JOURNAL OF ENHANCED HEAT TRANSFER, 2012, 19 (03) : 271 - 292
  • [2] EFFECT OF INLET CONFIGURATION ON DISTRIBUTION OF AIR-WATER UPWARD FLOW IN A HEADER OF A PARALLEL FLOW HEAT EXCHANGER
    Kim, Nae-Hyun
    Kim, Soo-Hwan
    Park, Ji-Hoon
    INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2010, 18 (04) : 265 - 277
  • [3] Two-phase flow distribution of air-water annular flow in a parallel flow heat exchanger
    Kim, Nae-Hyun
    Sin, Tae-Ryong
    INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2006, 32 (12) : 1340 - 1353
  • [4] R-134a distribution in a header of a parallel flow heat exchanger
    Kim, Nae-Hyun
    Lee, Eung-Ryul
    PROCEEDINGS OF THE 3RD ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING VOLS I AND II, 2006, : 105 - +
  • [5] Heat transfer to air-water annular flow in a horizontal pipe
    Zimmerman, R
    Gurevich, M
    Mosyak, A
    Rozenblit, R
    Hetsroni, G
    INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2006, 32 (01) : 1 - 19
  • [6] Prediction of film thickness distribution in horizontal air-water annular flow
    Fukano, Tohru
    Ousaka, Akiharu
    Nippon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B, 1988, 54 (505): : 2452 - 2458
  • [7] AIR-WATER COUNTERCURRENT ANNULAR FLOW.
    Bharathan, D.
    Electric Power Research Institute (Report) EPRI NP, 1979,
  • [8] Distribution of downward air-water flow in vertical tubes connected to a horizontal cylindrical header
    Shaban, H.
    Tavoularis, S.
    NUCLEAR ENGINEERING AND DESIGN, 2015, 291 : 90 - 100
  • [9] Air-water two-phase flow and heat transfer in a plate heat exchanger
    Vlasogiannis, P
    Karagiannis, G
    Argyropoulos, P
    Bontozoglou, V
    INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2002, 28 (05) : 757 - 772
  • [10] Two-phase refrigerant distribution in an intermediate header of a parallel flow minichannel heat exchanger
    Byun, Ho-Won
    Kim, Nae-Hyun
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2015, 59 : 14 - 28