摘要
Based on the point spread function of holographic system, the lateral resolution of digital holographic imaging system without any pre-magnification is studied. The expression of resolution limitation of holographic imaging system is thus presented. We investigate the possibilities to improve the lateral resolution. The simple experimental setup with an off-axis arrangement is built. By using a U.S. Air Force (USAF) test target as microscopic object, the recorded holograms are reconstructed digitally based on the principle of Fresnel diffraction. The lateral resolution of 2.76 mu m without any pre-magnification is demonstrated experimentally, which matches the theoretical prediction well.
引用
收藏
页码:165 / 167
页数:3
相关论文
共 50 条
  • [31] PHOTOELECTRON HOLOGRAPHY FOR HIGH-RESOLUTION SPECTROMICROSCOPY
    TONNER, BP
    ULTRAMICROSCOPY, 1991, 36 (1-3) : 130 - 141
  • [32] VIGNETTING IN HIGH-RESOLUTION ELECTRON HOLOGRAPHY
    LICHTE, H
    VOLKL, E
    EUREM 88, VOLS 1-3: TUTORIALS, INSTRUMENTATION AND TECHNIQUES / PHYSICS AND MATERIALS / BIOLOGY, 1988, 93 : 191 - 192
  • [33] PARAMETERS FOR HIGH-RESOLUTION ELECTRON HOLOGRAPHY
    LICHTE, H
    ULTRAMICROSCOPY, 1993, 51 (1-4) : 15 - 20
  • [34] HIGH-RESOLUTION CONTACT DENISYUK HOLOGRAPHY
    BJELKHAGEN, HI
    CHANG, J
    MONEKE, K
    APPLIED OPTICS, 1992, 31 (08) : 1041 - 1047
  • [35] PERFORMANCE OF HIGH-RESOLUTION MONITORS FOR DIGITAL CHEST IMAGING
    SUDDARTH, SA
    JOHNSON, GA
    SHERRIER, RH
    RAVIN, CE
    MEDICAL PHYSICS, 1987, 14 (02) : 253 - 257
  • [36] High-resolution terahertz inline digital holography based on quantum cascade laser
    Deng, Qinghua
    Li, Weihua
    Wang, Xuemin
    Li, Zeyu
    Huang, Haochong
    Shen, Changle
    Zhan, Zhiqiang
    Zou, Ruijiao
    Jiang, Tao
    Wu, Weidong
    OPTICAL ENGINEERING, 2017, 56 (11)
  • [37] Mechanical vibration measurement by high-resolution time-averaged digital holography
    Borza, DN
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2005, 16 (09) : 1853 - 1864
  • [38] HIGH-RESOLUTION IMAGING BY FOURIER-TRANSFORM X-RAY HOLOGRAPHY
    MCNULTY, I
    KIRZ, J
    JACOBSEN, C
    ANDERSON, EH
    HOWELLS, MR
    KERN, DP
    SCIENCE, 1992, 256 (5059) : 1009 - 1012
  • [39] HIGH-RESOLUTION IMAGING MAGNETIC ENERGY FILTERS WITH SIMPLE STRUCTURE
    LANIO, S
    OPTIK, 1986, 73 (03): : 99 - 107
  • [40] High-resolution digital holography using dual-wavelength coupled phase retrieval
    Zhao, Wanting
    Zhong, Zhi
    Liu, Bin
    Song, Diyao
    Liu, Lei
    Shan, Mingguang
    OPTICS AND LASERS IN ENGINEERING, 2025, 186