Does multifrequency bioelectrical impedance relate to body composition?

被引:4
|
作者
Suzuki, H
Rounds, JD
Wilmore, DM
机构
[1] BRIGHAM & WOMENS HOSP, DEPT SURG, SURG METAB & NUTR LAB, BOSTON, MA 02115 USA
[2] HARVARD UNIV, SCH MED, BOSTON, MA 02115 USA
关键词
D O I
10.1006/jsre.1996.0344
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: There is need for a rapid, noninvasive, inexpensive yet accurate bedside technique to measure body composition. Bioelectrical impedance analysis measures the resistance and conductance of a weak electrical current passed through the body. It has been suggested that multifrequency impedance analysis can determine the distribution of fluid between the extracellular and intracellular compartments. Materials and Methods: The correlation between the resistance signals obtained from multifrequency bioelectrical impedance measurements and body composition was determined in normal rats ranging from 150 to - 400 g in weight. Total body water, body fat, total body sodium, and total body potassium were measured using the carcass analysis technique, and extracellular water was derived from a dilutional marker using sodium bromide. Fat-free mass was calculated as the difference between body weight and body fat, and intracellular water was derived from total body water and extracellular water. Multifrequency bioelectrical impedance was measured at frequencies ranging from 3 to 300 kHz. Resistance at zero frequency and infinite frequency was calculated using the Cole and Cole equation. Results: Resistance index (i.e., length of the animal(2)/resistance) was highly correlated with all body compartments (r = 0.879-0.996) at all frequencies. There was also a high correlation among all compartments of the body (r = 0.971-0.999). Because of this high intercorrelation among the body compartments, a specific relationship between the multifrequency bioelectrical impedance signal and a specific compartment was not identified. Conclusions: Resistance index at any frequency will be correlated with any body compartment in a normal population. The utility of this technique should be determined in situations where there is a disturbance in the relationship between various compartments of the body. (C) 1996 Academic Press, Inc.
引用
收藏
页码:63 / 69
页数:7
相关论文
共 50 条
  • [41] BIOELECTRICAL IMPEDANCE FOR THE ASSESSMENT OF BODY-COMPOSITION OF DIALYZED PATIENTS
    BIASIOLI, S
    PETROSINO, Z
    CAVALLI, L
    ZAMBELLO, A
    CESARO, A
    FAZION, S
    CLINICAL NEPHROLOGY, 1989, 31 (05) : 274 - 275
  • [42] Qualitative human body composition analysis assessed with bioelectrical impedance
    Talluri, T
    COLLEGIUM ANTROPOLOGICUM, 1998, 22 (02) : 427 - 432
  • [43] BIOELECTRICAL IMPEDANCE ANALYSIS AS A METHOD TO ASSESS BODY-COMPOSITION
    LAWLOR, MR
    CRISMAN, RP
    HODGDON, JA
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1985, 17 (02): : 271 - 272
  • [44] BODY-COMPOSITION MEASURED BY BIOELECTRICAL IMPEDANCE AND HYDROSTATIC WEIGHING
    MILES, DS
    STEVENS, AG
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1985, 17 (02): : 272 - 273
  • [45] ASSESSMENT OF BODY COMPOSITION IN CHILDREN BY BIOELECTRICAL IMPEDANCE AND SKINFOLD ANTHROPOMETRY
    Vidueiros, Silvina M.
    Tarducci, Gabriel O.
    Morea, Guillermo
    Bardach, Ariel
    Paganini, Amalia
    Dimarco, Gabriela
    Aquino, Bernardo
    Calbe, Silvina
    Pallaro, Anabel N.
    ANNALS OF NUTRITION AND METABOLISM, 2009, 55 : 479 - 480
  • [46] Prediction of body composition of Iberian pigs by means bioelectrical impedance
    Daza, A
    Mateos, A
    Ovejero, I
    Bote, CJL
    MEAT SCIENCE, 2006, 72 (01) : 43 - 46
  • [47] Evaluation of bioelectrical impedance analysis as an estimator of moose body composition
    Hundertmark, KJ
    Schwartz, CC
    WILDLIFE SOCIETY BULLETIN, 2002, 30 (03) : 915 - 921
  • [48] The use of bioelectrical impedance analysis for body composition in epidemiological studies
    A Böhm
    B L Heitmann
    European Journal of Clinical Nutrition, 2013, 67 : S79 - S85
  • [49] Body composition by bioelectrical impedance analysis in renal transplant recipients
    Wong, HS
    Boey, LM
    Morad, Z
    TRANSPLANTATION PROCEEDINGS, 2004, 36 (07) : 2186 - 2187
  • [50] MEASUREMENT OF BODY-COMPOSITION USING BIOELECTRICAL IMPEDANCE ANALYSIS
    LUBANSKI, RE
    KURZER, M
    MEGUID, MM
    CLINICAL RESEARCH, 1987, 35 (03): : A775 - A775