A New Current Transducer for On-Line Monitoring of Leakage Current on HV Insulator Strings

被引:12
|
作者
Villalobos, Rodrigo J. [1 ]
Moran, Luis A. [2 ]
Huenupan, Fernando [1 ]
Vallejos, Francisco [1 ]
Moncada, Roberto [1 ]
Pesce, Cristian G. [1 ]
机构
[1] Univ La Frontera, Dept Elect Engn, Temuco 4811230, Chile
[2] Univ Concepcion, Dept Elect Engn, Concepcion 4030000, Chile
关键词
Insulators; Transducers; Leakage currents; Current measurement; Pollution measurement; Transmission line measurements; Pollution; Current transducer; HV insulator strings; leakage current; on-line monitoring; pollution level estimation; CONTAMINATION LEVEL; FLASHOVER PROCESS; CURRENT INDEX; VOLTAGE; POLLUTION; PORCELAIN;
D O I
10.1109/ACCESS.2022.3191349
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Leakage current measurement and its harmonics have been widely used for the pollution level estimation of HV insulator strings. However, the solutions available to applications into transmission lines and substations are few and it reduces the creepage distance (mm/kV), must be installed by de-energizing the electrical power system or do not allow the characteristic harmonics of the leakage current to be obtained. This paper presents the design, implementation, testing, and experimental validation of a transducer for measuring and online monitoring of leakage currents on high-voltage insulator strings. The transducer is composed of a clamp-type current transformer with a supermalloy material core. The leakage current is reconstructed from the transducer output voltage by applying the Fast Fourier Transform (FFT) and its own inverse transfer function, which allows it to obtain the leakage current with its characteristic harmonics and reduces the electromagnetic noise present in power systems. The output voltage of the transducer was acquired, processed, and transmitted using a dedicated device installed in the HV tower. The proposed transducer was first tested on an insulator inside an artificial fog chamber according to the IEC 60507 standard. The transducer was experimentally validated on an insulator string in a 220 kV substation. The results showed that the designed transducer measured the leakage current and its harmonics with an average error less than 1.76%. With these results the transducer can be used for the on-line monitoring of pollution levels of insulator strings without reduces the creepage distance.
引用
收藏
页码:78818 / 78826
页数:9
相关论文
共 50 条
  • [21] Leakage Current Monitoring of Distribution Line Spacers
    Pinheiro, Walter
    Kanashiro, Arnaldo G.
    Burani, Geraldo F.
    PC 2008: PROCEEDINGS OF THE 8TH WSEAS INTERNAITONAL CONFERENCE ON POWER SYSTEMS AND POWER TECHNOLOGY, 2008, : 252 - 257
  • [22] The design of synchronous sampling unit in on-line resistive leakage current monitoring system of MOA
    Wang, YQ
    Lu, FC
    Li, HM
    Li, YQ
    Proceedings of the 2005 International Symposium on Electrical Insulating Materials, Vols, 1-3, 2005, : 472 - 475
  • [23] Influence of power system's harmonic voltage on on-line leakage current monitoring of MOA
    Wang, YQ
    Lu, FC
    Li, HM
    2004 3RD INTERNATIONAL CONFERENCE ON COMPUTATIONAL ELECTROMAGNETICS AND ITS APPLICATIONS, PROCEEDINGS, 2004, : 268 - 271
  • [24] Network-model on-line monitoring system of leakage current of ZnO surge arresters
    Deng, Wei
    Liu, Weidong
    Fu, Zhiyang
    Cao, Jian
    Gaodianya Jishu/High Voltage Engineering, 2003, 29 (09):
  • [25] Impulse voltage characteristics for HV transmission line insulator strings
    Enache, R.
    Coatu, S.
    Baran, Ileana
    Nicoara, B.
    Revue roumaine de sciences techniques. Serie electrotechnique et energetique, 1988, 33 (03): : 253 - 266
  • [26] Study of adaptive noise cancellation used in measuring HV insulator's leakage current
    Liu, D.C.
    Xia, L.M.
    Shang, Z.H.
    Wuhan Daxue Xuebao (Gongxue Ban)/Engineering Journal of Wuhan University, 2001, 34 (04):
  • [27] INSULATOR LEAKAGE CURRENT MONITORING: CHALLENGES FOR HIGH VOLTAGE DIRECT CURRENT TRANSMISSION LINES
    Roman, M.
    van Zyl, R. R.
    Parus, N.
    Mahatho, N.
    PROCEEDINGS OF THE 2014 11TH INTERNATIONAL CONFERENCE ON THE INDUSTRIAL AND COMMERCIAL USE OF ENERGY (ICUE), 2014, : 314 - 320
  • [28] Monitoring Porcelain Insulator Condition Based on Leakage Current Characteristics
    Salem, Ali Ahmed
    Lau, Kwan Yiew
    Ishak, Mohd Taufiq
    Abdul-Malek, Zulkurnain
    Al-Gailani, Samir A.
    Al-Ameri, Salem Mgammal
    Mohammed, Ammar
    Alashbi, Abdulaziz Ali Saleh
    Ghoneim, Sherif S. M.
    MATERIALS, 2022, 15 (18)
  • [29] Novel sensor system for leakage current detection on insulator strings of overhead transmission lines
    Fontana, Eduardo
    Oliveira, S. Campello
    Cavalcanti, F. J. M. M.
    Lima, R. Bandeira
    Martins-Filho, J. F.
    Meneses-Pacheco, E.
    2006 IEEE/PES Power Systems Conference and Exposition. Vols 1-5, 2006, : 2255 - 2255
  • [30] New type of pulse current sensors for on-line partial discharge monitoring
    Fang, Q
    Xu, Y
    Cao, XL
    Geng, FH
    Ding, R
    Lu, G
    PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2003, : 298 - 301