Performance of the electrostatic collection type radon and toron detector

被引:0
|
作者
Noto, N [1 ]
Ohsumi, H [1 ]
Kobayashi, S [1 ]
机构
[1] Saga Univ, Fac Sci & Engn, Dept Phys, Saga 8408502, Japan
关键词
radon/toron detector; half life; effect of humidity; nobe gas environment;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The major background source in the underground experiments, such as a search for the double beta decay, is recognized as the radio-active materials, specifically the daughter nucleus of toron, Tl-208, in the environment as well as the detector iteself. To measure such contamination, a large volume electrostatic collection-type detector having radon sensitivity, or the detection limit, of the order of 10mBq/m(3) is commonly used. In case, for example, of an experimental configuration utilizing a drift chamber, the measurement of radio-active contamination in the filling gas is crucial. The present detector seems to be useful in the estimate of minute amount of the radon as well as the toron in the gas. To understand such type of the detector, we have studied a general behavior of the 1 l volume detector, inside of which is a PIN photodiode held at a negative potential. The radio-active ions, such as poloniums and bismuth, are collected and their a decays are detected as clearly separated several peaks. Some results are presented in this report for the lifetime measurements of natural radon Rn-222 and toron Pb-212. Other results also will be presented, such as a relation between the collection efficiency of the daughter nucleus, Po-218, and the humidity.
引用
收藏
页码:429 / 434
页数:6
相关论文
共 50 条
  • [21] AN IMPROVED ELECTROSTATIC INTEGRATING RADON MONITOR WITH THE CR-39 AS ALPHA-PARTICLE DETECTOR
    Fan, D.
    Zhuo, W.
    Chen, B.
    Zhao, C.
    Yi, Y.
    Zhang, Y.
    RADIATION PROTECTION DOSIMETRY, 2015, 167 (1-3) : 121 - 125
  • [23] Developing a radon monitor for simultaneous measurement of Rn-222 and Rn-220 with less influence of humidity based on electrostatic collection and CR-39 detector
    Fan, Zhongkai
    Shan, Jian
    Lin, Fen
    Hu, Tao
    Mo, Yixiang
    Xie, Ruomei
    Yuan, Shuai
    Liu, Shuaibin
    Li, Huiying
    Yi, Haibo
    Sun, Jiale
    Wu, Jiulin
    Liu, Zhipeng
    Chen, Linquan
    Yuan, Hongzhi
    Tan, Yanliang
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 1052
  • [24] Effects of thoron on a radon detector of pulse-ionization chamber type
    Ishikawa, T
    RADIATION PROTECTION DOSIMETRY, 2004, 108 (04) : 327 - 330
  • [25] Electrostatic field in microstrip chambers and its influence on detector performance
    Florent, J.J.
    Gaudaen, J.
    Ropelewski, L.
    Sauli, F.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1993, A329 (1-2) : 125 - 132
  • [26] Experimental study on collection performance of dipolar charging electrostatic precipitator
    Chen, Wangsheng
    Guo, Junyi
    Li, Weijie
    Xiang, Xiaodong
    Lu, Jidong
    2008 PROCEEDINGS OF INFORMATION TECHNOLOGY AND ENVIRONMENTAL SYSTEM SCIENCES: ITESS 2008, VOL 4, 2008, : 926 - 928
  • [27] Lateral collection structure for planar type InGaAs infrared detector
    Deng, Honghai
    Wang, Zhiliang
    Huang, Jing
    Li, Xue
    Gong, Haimei
    OPTICAL SENSING AND IMAGING TECHNOLOGIES AND APPLICATIONS, 2018, 10846
  • [28] SSNTDs in the automatic detector of radon
    Nevinsky, I
    Tsvetkova, T
    RADIATION MEASUREMENTS, 2005, 39 (01) : 115 - 119
  • [29] A SUPERSENSITIVE DETECTOR FOR RADON IN WATER
    FISCHER, UH
    JURY, JW
    CHEMICAL GEOLOGY, 1988, 70 (1-2) : 98 - 98
  • [30] A radon detector for earthquake prediction
    不详
    PHYSICS WORLD, 2010, 23 (04) : 5 - 5