Design and development of radio frequency system for pulse positron low energy beam and its electron beam trials

被引:0
|
作者
Shrotriya, S. [1 ]
Mukherjee, S. [2 ]
Jena, S. S. [1 ]
Shiju, A. [1 ]
Patel, N. [1 ]
Maheshwari, P. [2 ]
Sharma, S. K. [2 ]
Dutta, D. [2 ]
Sudarshan, K. [2 ]
Pande, M. [1 ]
Joshi, G. [1 ]
Pujari, P. K. [2 ,3 ]
机构
[1] Bhabha Atom Res Ctr, Accelerator Control Div, Mumbai 400085, Maharashtra, India
[2] Bhabha Atom Res Ctr, Radiochem Div, Mumbai 400085, Maharashtra, India
[3] Homi BhaBha Nation Inst, Mumbai 400085, Maharashtra, India
关键词
Spectrometers; Analogue electronic circuits; Instrument optimisation; LIFETIME;
D O I
10.1088/1748-0221/16/09/T09002
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Details of the design and development of radio frequency (RF) system at 37.5 MHz and 150 MHz and initial test results of electron beam trials of a pulsed positron beam line being developed at BARC, Mumbai are presented in this paper. The RF part of the beam line is based on the conventional positron pulsing technique of chopper-pre buncher-buncher arrangement. Picosecond (ps) pulsing is achieved by a 150 MHz quarter wave resonator, which times focuses the chopped positron beam onto the sample. The chopper and pre buncher, preceding the buncher, are designed to operate at one-fourth of the frequency of the buncher. The reflection type grid chopper uses sinusoidal waves riding on a DC offset to chop the incoming beam into less than 2 ns pulses. These various structures were excited by the RF power coupled from an overall two frequency RF system. This RF system comprises of amplifiers at 37.5 MHz and 150 MHz that derive a single common input from an arbitrary frequency generator (AFG) to reduce the timing distortion, their respective impedance matching units and RF coupling lines made of RF components used for amplitude and phase adjustments and then, feeds the RF power to these structures. The RF system was initially tested on a prototype setup before incorporating in the main pulsed positron beam line. RF interference suppression techniques like filtering and shielding were used to ensure minimum interference between RF signals and the various detector electronics. Before positron beam trials, electron beam trials were performed in the positron beam line. A final pulse width 280 ps was measured with an electron beam.
引用
收藏
页数:21
相关论文
共 50 条
  • [1] A LOW ENERGY POSITRON BEAM SYSTEM
    JADUSZLIWER, B
    BOWDEN, TJ
    PAUL, DAL
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1970, 15 (06): : 785 - +
  • [2] DESIGN OF A LOW-ENERGY POSITRON BEAM
    BRITTON, DT
    RICEEVANS, PC
    EVANS, JH
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1985, 12 (03): : 426 - 429
  • [3] DESIGN OF A LOW ENERGY POSITRON BEAM.
    Britton, D.T.
    Rice-Evans, P.C.
    Evans, J.H.
    Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms, 1985, B12 (03) : 426 - 429
  • [4] Radio frequency elevator for a pulsed positron beam
    Dickmann, Marcel
    Mitteneder, Johannes
    Koegel, Gottfried
    Egger, Werner
    Sperr, Peter
    Ackermann, Ulrich
    Piochacz, Christian
    Dollinger, Guenther
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 821 : 40 - 43
  • [5] Positron beam development and design
    Zecca, A
    APPLIED SURFACE SCIENCE, 2002, 194 (1-4) : 4 - 12
  • [6] Development of a beam energy adjustment system after a Radio-Frequency-Quadrupole
    Yang, Y.
    Tian, R. X.
    Zhai, Y. H.
    Wang, X. W.
    Jin, X. F.
    Li, L. B.
    Jing, L.
    Li, J. B.
    Zhang, B.
    Tang, Y.
    Mao, R. S.
    Xu, Z. G.
    Ma, H. Y.
    Xu, X. B.
    Zhu, T. M.
    Zhang, P.
    Guo, Y. H.
    Zhang, W. H.
    Feng, Y. C.
    Sun, L. T.
    Tang, X. D.
    Zhao, H. W.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2022, 1039
  • [7] Experimental study on low energy beam transport system of radio frequency quadrupole accelerator
    China Institute of Atomic Energy, P.O. Box 275-27, Beijing 102413, China
    不详
    Yuanzineng Kexue Jishu, 2008, 2 (97-100): : 97 - 100
  • [8] The beam energy measurement system for the Beijing electron-positron collider
    Zhang, J. Y.
    Abakumova, E. V.
    Achasov, M. N.
    Blinov, V. E.
    Cai, X.
    Dong, H. Y.
    Fu, C. D.
    Harris, F. A.
    Kaminsky, V. V.
    Krasnov, A. A.
    Liu, Q.
    Mo, X. H.
    Muchnoi, N. Yu.
    Nikolaev, I. B.
    Qin, Q.
    Qu, H. M.
    Olsen, S. L.
    Pyata, E. E.
    Shamov, A. G.
    Shen, C. P.
    Todyshev, K. Yu.
    Varner, G. S.
    Wang, Y. F.
    Xiao, Q.
    Xu, J. Q.
    Zhang, T. B.
    Zhang, Y. H.
    Zhukov, A. A.
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2012, 225 : 309 - 314
  • [9] The beam energy measurement system for the Beijing electron-positron collider
    Abakumova, E. V.
    Achasov, M. N.
    Blinov, V. E.
    Cai, X.
    Dong, H. Y.
    Fu, C. D.
    Harris, F. A.
    Kaminsky, V. V.
    Krasnov, A. A.
    Liu, Q.
    Mo, X. H.
    Muchnoi, N. Yu.
    Nikolaev, I. B.
    Qin, Q.
    Qu, H. M.
    Olsen, S. L.
    Pyata, E. E.
    Shamov, A. G.
    Shen, C. P.
    Todyshev, K. Yu.
    Varner, G. S.
    Wang, Y. F.
    Xiao, Q.
    Xu, J. Q.
    Zhang, J. Y.
    Zhang, T. B.
    Zhang, Y. H.
    Zhukov, A. A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 659 (01): : 21 - 29
  • [10] GENERATION OF A LOW-ENERGY POSITRON BEAM
    LOHNERT, GH
    SCHNEIDER, RT
    NUCLEAR TECHNOLOGY, 1971, 10 (03) : 315 - +