INFLUENCE OF TIP CLEARANCE ON THE PERFORMANCE AND MATCHING OF MULTISTAGE AXIAL COMPRESSORS

被引:0
|
作者
Zheng, Xinqian [1 ]
Yang, Heli [1 ]
机构
[1] Tsinghua Univ, Turbomachinery Lab, State Key Lab Automot Safety & Energy, Beijing 100084, Peoples R China
关键词
FLOW;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Tip clearance has great influence on the performance of multistage axial compressors including efficiency, pressure rise, mass flow, as well as matching. This paper reports a study into the influence of tip clearance on the performance and matching of a 5-stage axial compressor by a numerical method. Different tip clearances from 0% to 5.0% span which represents the typical range of tip clearance in modern multistage axial compressors were simulated and analyzed. The results show that as tip clearance increases from 0% to 5.0% span, the choked mass flow decreases by about 21.8%, the peak pressure ratio decreases by about 43.1% and the peak efficiency decreases about 14.3 percents. As tip clearance increases, the efficiency of the whole compressor decreases in a parabolic manner not linearly as previous suggested, which is partially attributable to the cantilevered stators considered in this paper and primarily due to the mismatching of different stages. It is of great importance to control the tip clearance. When tip clearance increases, the front stage tends to work near surge condition and the rear stage tends to work near choke condition, which leads to lower efficiency than in the middle stages. A weight was defined to evaluate each stage's contribution to the whole compressor's efficiency deficit caused by the increase of tip clearance. Front and rear stages contribute more to the efficiency deficit than the middle stages, which indicates that more attention should be paid on front and rear stages to improve the performance of multistage axial compressors. In order to evaluate the matching of multistage axial compressors with a quantified method, a new parameter named "Peak Efficiency Deviation (PED)" was defined based on the difference between each stage's operating efficiency and its peak efficiency. The mass flow of multistage axial compressors should be well considered to make the PED parameter to be close to zero as possible. In the most commonly used range of tip clearance from 0.5% to 3.0% span, the PED varies little within 0.4 percent, which is only about 8.4% of the peak efficiency deficit at 1.5% span tip clearance. So, the PED could be small within a wide range of tip clearances if the matching of the compressor is perfect at design tip clearance.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Numerical Simulation of Particulates in Multistage Axial Compressors
    Saxena, Swati
    Jothiprasad, Giridhar
    Bourassa, Corey
    Pritchard, Byron
    JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2017, 139 (03):
  • [42] OVERALL PERFORMANCE OF MULTISTAGE AXIAL-FLOW COMPRESSORS WITH RADIAL END STAGE
    STAUDE, R
    ATOMKERNENERGIE, 1978, 32 (04): : 279 - 283
  • [43] Effect of tip clearance and rotor-stator axial gap on the efficiency of a multistage compressor
    Danish, Syed Noman
    Qureshi, Shafiq Rehman
    Imran, Malik Muhammad
    Khan, Salah Ud-Din
    Sarfraz, Muhammad Mansoor
    El-Leathy, Abdelrahman
    Al-Ansary, Hany
    Wei, Mingshan
    APPLIED THERMAL ENGINEERING, 2016, 99 : 988 - 995
  • [44] A Correction Method for the Effects of Reynolds Number, Roughness, and Tip Clearance on Geometric Scaling of Axial Compressors
    Liu, Yitong
    Gong, Wuqi
    Liang, Lu
    Wang, Qi
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2023, 145 (10):
  • [45] Influence of tip clearance on pressure fluctuations in an axial flow pump
    Feng, Jianjun
    Luo, Xingqi
    Guo, Pengcheng
    Wu, Guangkuan
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2016, 30 (04) : 1603 - 1610
  • [46] Influence of tip clearance on pressure fluctuations in an axial flow pump
    Jianjun Feng
    Xingqi Luo
    Pengcheng Guo
    Guangkuan Wu
    Journal of Mechanical Science and Technology, 2016, 30 : 1603 - 1610
  • [47] Influence of Non-Uniform Blade Tip Clearance on the Performance of a Large Axial Flow Fan
    Cheng K.
    Chen Y.
    Meng F.
    Li J.
    Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 2022, 56 (10): : 180 - 189
  • [48] Effects of nonaxisymmetric tip clearance on axial compressor performance and stability
    Graf, MB
    Wong, TS
    Greitzer, EM
    Marble, FE
    Tan, CS
    Shin, HW
    Wisler, DC
    JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 1998, 120 (04): : 648 - 661
  • [49] Effects of nonaxisymmetric tip clearance on axial compressor performance and stability
    Graf, M.B.
    Wong, T.S.
    Greitzer, E.M.
    Marble, F.E.
    Tan, C.S.
    Shin, H.-W.
    Wisler, D.C.
    Journal of Turbomachinery, 1998, 120 (04): : 648 - 661
  • [50] THE EFFECT OF TIP CLEARANCE ON THE PERFORMANCE OF AN AXIAL-FLOW FAN
    VENTER, SJ
    KROGER, DG
    ENERGY CONVERSION AND MANAGEMENT, 1992, 33 (02) : 89 - 97