Comparison of Three High Resolution Real-Time Spectrometers for Microwave Ozone Profiling Instruments

被引:5
|
作者
Sauvageat, Eric [1 ,2 ]
Albers, Roland [1 ]
Kotiranta, Mikko [1 ]
Hocke, Klemens [1 ,2 ]
Gomez, R. Michael [3 ]
Nedoluha, Gerald [3 ]
Murk, Axel [1 ,2 ]
机构
[1] Univ Bern, Inst Appl Phys, CH-3012 Bern, Switzerland
[2] Univ Bern, Oeschger Ctr Climate Change Res, CH-3012 Bern, Switzerland
[3] US Naval Res Lab, Remote Sensing Div, Washington, DC 20375 USA
关键词
Gases; Atmospheric measurements; Radiometers; Instruments; Microwave radiometry; Time series analysis; Real-time systems; digital real-time spectrometers; microwave radiometry; microwave spectroscopy; ozone; remote sensing; water vapor; WATER-VAPOR;
D O I
10.1109/JSTARS.2021.3114446
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this contribution, we present a comparison of three digital real-time spectrometers used in passive remote sensing of ozone and other trace gases in the middle atmosphere. During a period of six months, we connected the spectrometers to the same radiometric front-end to perform parallel observations of the ozone emission line at 110.836 GHz. This allowed us to better characterize a bias previously observed on the integrated spectra of the Acqiris AC240, a widely used digital spectrometer which has been used for more than a decade in many operational microwave radiometers. We investigated the bias under different atmospheric conditions and found that it is caused by multiple sources. Nonlinearities in the calibration are responsible for part of the bias, but a larger contribution stems from a second effect in the AC240. Although this error source is still partly unexplained, we found that a simple correction scheme simulating a spectral leakage can be applied to the integrated spectra of the AC240 and worked well on our range of observations. We also show that by applying our bias correction to the spectra, we can correct the bias in the ozone retrievals. There is still a need for further measurements to validate this approximate correction, but it could help to correct the numerous time series of ozone and other atmospheric constituents recorded by the AC240.
引用
收藏
页码:10045 / 10056
页数:12
相关论文
共 50 条
  • [41] High Resolution Radar Real-Time Signal and Information Processing
    Teng Long
    Tao Zeng
    Cheng Hu
    Xichao Dong
    Liang Chen
    Quanhua Liu
    Yizhuang Xie
    Zegang Ding
    Yang Li
    Yanhua Wang
    Yan Wang
    中国通信, 2019, 16 (02) : 105 - 133
  • [42] Real-time High Resolution Fusion of Depth Maps on GPU
    Trifonov, Dmitry S.
    2013 INTERNATIONAL CONFERENCE ON COMPUTER-AIDED DESIGN AND COMPUTER GRAPHICS (CAD/GRAPHICS), 2013, : 441 - 442
  • [43] Design of ultra high resolution real-time display system
    Liu, Yu
    Hu, Ya-Hua
    Lu, Li
    Tang, Bo
    Yu, Li-Fu
    Guofang Keji Daxue Xuebao/Journal of National University of Defense Technology, 2002, 24 (03):
  • [44] High-resolution, real-time fringe pattern profilometry
    Karpinsky, Nikolaus
    Lei, Shuangyan
    Zhang, Song
    FOURTH INTERNATIONAL CONFERENCE ON EXPERIMENTAL MECHANICS, 2010, 7522
  • [45] Real-time watermark embedding for high resolution video watermarking
    Kang, In-Koo
    Im, Dong-Hyuck
    Suh, Young-Ho
    Lee, Heung-Kyu
    ADVANCES IN INFORMATION AND COMPUTER SECURITY, PROCEEDINGS, 2006, 4266 : 227 - 238
  • [46] High Resolution, Real-Time Interferometer for Coherent Beam Combination
    Simion, Sandel
    Blanaru, Constantin
    Ursescu, Daniel
    LIGHT AT EXTREME INTENSITIES: OPPORTUNITIES AND TECHNOLOGICAL ISSUES OF THE EXTREME LIGHT INFRASTRUCTURE, 2010, 1228 : 272 - 276
  • [47] HIGH-RESOLUTION REAL-TIME ULTRASOUND OF THE CAROTID BIFURCATION
    COOPERBERG, PL
    ROBERTSON, WD
    FRY, P
    SWEENEY, V
    JOURNAL OF CLINICAL ULTRASOUND, 1979, 7 (01) : 13 - 17
  • [48] Towards an Embedded Real-Time High Resolution Vision System
    Ekstrand, Fredrik
    Ahlberg, Carl
    Ekstrom, Mikael
    Spampinato, Giacomo
    ADVANCES IN VISUAL COMPUTING (ISVC 2014), PT II, 2014, 8888 : 541 - 550
  • [49] High-resolution, real-time exercise stress cine
    Rizwan Ahmad
    Samuel T Ting
    Jason Craft
    Shivraman Giri
    Ning Jin
    Subha V Raman
    Orlando P Simonetti
    Journal of Cardiovascular Magnetic Resonance, 16 (Suppl 1)
  • [50] HIGH-RESOLUTION REAL-TIME SONOGRAPHY OF SCROTAL VARICOCELE
    WOLVERSON, MK
    HOUTTUIN, E
    HEIBERG, E
    SUNDARAM, M
    GREGORY, J
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1983, 141 (04) : 775 - 779