Theoretical and experimental investigation of pressure drop and refrigeration effect in pulse tube cryocooler

被引:0
|
作者
Badgujar, A. D. [1 ]
Atrey, M. D. [1 ]
机构
[1] Indian Inst Technol, Dept Mech Engn, Bombay 400076, Maharashtra, India
关键词
Pulse tube cryocooler; pressure drop; regenerator mesh; L/D ratio;
D O I
10.1177/0954406215584393
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The design of a highly efficient pulse tube cryocooler (PTC) is a subject of recent research activities. The PTC performance depends on various operating and design parameters. Regenerator is one of the very important components of the PTC which decides the low temperature that the PTC can attain. Efficiency of regenerator should be high enough, 96% or above, in order to reach very low temperature while the pressure drop in the regenerator is one of the parameters which needs to be analysed in detail. In the present work, theoretical and experimental investigations are carried out on two different single stage U type PTC. The volumes of regenerators and pulse tubes, in both the cases are kept same while the length to diameter (L/D) ratios of regenerators are changed. Investigations are carried out on these PTC with respect to pressure drop in the regenerator and net refrigeration effect obtained from the PTC at 80K. The pressure drop increases from 0.29bar to 2.07bar with an increase in L/D ratio from 1.93 to 9, resulting in decrease in refrigeration effect from 6.1W to 1.7W at 80K with 300W input power. The study is further extended to understand the effect of coarse size stainless steel mesh size in the regenerator. Coarse size meshes filled up to 60% of regenerator length improved the refrigeration effect from 1.7W to 2.8W; however, further filling degrades the performance of the PTC. The experimental results are compared with theoretical results obtained by Sage software and Isothermal model.
引用
收藏
页码:1910 / 1920
页数:11
相关论文
共 50 条
  • [41] Design and preliminary experimental investigation of a 4 K Stirling-type pulse tube cryocooler with precooling
    Zhi-hua Gan
    Zhuo-pei Li
    Jie Chen
    Li Dai
    Li-min Qiu
    Journal of Zhejiang University-SCIENCE A, 2009, 10 : 1277 - 1284
  • [42] Theoretical and experimental study for the transient behavior of a linear compressor during pulse tube cryocooler cool down process
    Wang, Bo
    Li, Ruize
    Chao, Yijun
    Zhuang, Changpei
    Zhao, Qinyu
    Sun, Shuze
    Yan, Chunjie
    Gan, Zhihua
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 150 : 304 - 312
  • [43] Numerical investigation on a 70 Hz pulse tube micro-cryocooler
    Nekrasova, S. O.
    Zinovyev, E. A.
    Dovgyallo, A. I.
    OIL AND GAS ENGINEERING (OGE-2016), 2016, 152 : 314 - 320
  • [44] Investigation on the ultra-high frequency coaxial pulse tube cryocooler
    Xu N.
    Chen H.
    Liang J.
    Cai J.
    Yang L.
    Jixie Gongcheng Xuebao/Journal of Mechanical Engineering, 2011, 47 (06): : 156 - 159
  • [45] The Numerical Simulation and Experimental Study on a VM Type Pulse Tube Cryocooler
    Dai, Wei (cryodw@mail.ipc.ac.cn), 1600, Science Press (38):
  • [46] Fluid mechanical response of a pulse tube cryocooler: modelling and experimental validation
    Lauzier, K.
    Bribiesca-Argomedo, F.
    Gauthier, J-Y
    Sesmat, S.
    Lin-Shi, X.
    Lopes, D. Carvalho
    ADVANCES IN CRYOGENIC ENGINEERING, 2020, 755
  • [47] THERMODYNAMIC ANALYSIS AND EXPERIMENTAL VERFICATION ON A NOVEL LOOPED PULSE TUBE CRYOCOOLER
    Wang, Xiaotao
    Luo, Ercang
    Dai, Wei
    Hu, Jianying
    Zhou, Yuan
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS 57A AND 57B, 2012, 1434 : 1908 - 1915
  • [48] Experimental study of the oscillating flow characteristics for a regenerator in a pulse tube cryocooler
    Ju, YL
    Jiang, Y
    Zhou, Y
    CRYOGENICS, 1998, 38 (06) : 649 - 656
  • [49] Experimental investigation of heat transfer and pressure drop in a circular tube with multiple inserts
    Vashistha, Chaitanya
    Patil, Anil Kumar
    Kumar, Manoj
    APPLIED THERMAL ENGINEERING, 2016, 96 : 117 - 129