The Need for Standardization of Tacrolimus Assays

被引:49
|
作者
Levine, Daniel M. [1 ]
Maine, Gregory T. [2 ]
Armbruster, David A. [2 ]
Mussell, Christopher [3 ]
Buchholz, Christoph [3 ]
O'Connor, Gavin [3 ]
Tuck, Victoria [4 ]
Johnston, Atholl [4 ]
Holt, David W. [4 ]
机构
[1] Rogosin Inst, New York, NY 10065 USA
[2] Abbott Diagnost, Abbott Pk, IL USA
[3] LGC Ltd, Chem Measurement & Calibrat, Teddington, Middx, England
[4] St Georges Univ London, Analyt Serv Int Ltd, London, England
关键词
TRANSPLANTATION; IMMUNOASSAY; DRUGS;
D O I
10.1373/clinchem.2011.172080
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
BACKGROUND: Owing to the lack of an internationally recognized tacrolimus reference material and reference method, current LC-MS and immunoassay test methods used to monitor tacrolimus concentrations in whole blood are not standardized. The aim of this study was to assess the need for tacrolimus assay standardization. METHODS: We sent a blinded 40-member whole-blood tacrolimus proficiency panel (0-30 mu g/L) to 22 clinical laboratories in 14 countries to be tested by the following assays: Abbott ARCHITECT (n = 17), LC-MS (n = 9), and Siemens Dade Dimension (n = 5). Selected LC-MS laboratories (n = 4) also received a common calibrator set. We compared test results to a validated LC-MS method. Four samples from the proficiency panel were assigned reference values by using exact-matching isotope-dilution mass spectrometry at LGC. RESULTS: The range of CVs observed with the tacrolimus proficiency panel was as follows: LC-MS 11.4%-18.7%, ARCHITECT 3.9%-9.5%, and Siemens Dade 5.0%-48.1%. The range of historical within-site QC CVs obtained with the use of 3 control concentrations were as follows: LC-MS low 3.8%-10.7%, medium 2.0%-9.3%, high 2.3%-9.0%; ARCHITECT low 2.5%-9.5%, medium 2.5%-8.6%, high 2.9%-18.6%; and Siemens/Dade Dimension low 8.7%-23.0%, medium 7.6%-13.2%, high 4.4%-10.4%. Assay bias observed between the 4 LC-MS sites was not corrected by implementation of a common calibrator set. CONCLUSIONS: Tacrolimus assay standardization will be necessary to compare patient results between clinical laboratories. Improved assay accuracy is required to provide optimized drug dosing and consistent care across transplant centers globally. (C) 2011 American Association for Clinical Chemistry
引用
收藏
页码:1739 / 1747
页数:9
相关论文
共 50 条
  • [31] Tacrolimus metabolite cross-reactivity in different tacrolimus assays
    Murthy, JN
    Davis, DL
    Yatscoff, RW
    Soldin, SJ
    CLINICAL BIOCHEMISTRY, 1998, 31 (08) : 613 - 617
  • [32] Imaging: the need for standardization
    Lassere, Marissa N.
    BEST PRACTICE & RESEARCH IN CLINICAL RHEUMATOLOGY, 2008, 22 (06): : 1001 - 1018
  • [33] NEED FOR STANDARDIZATION IN BACTERIOLOGY
    BLACK, WA
    DORSE, SE
    CANADIAN JOURNAL OF PUBLIC HEALTH-REVUE CANADIENNE DE SANTE PUBLIQUE, 1976, 67 (02): : 141 - 141
  • [34] PERIMETRY - NEED FOR STANDARDIZATION
    SCHOESSLER, JP
    UNIACKE, CA
    AMERICAN JOURNAL OF OPTOMETRY AND PHYSIOLOGICAL OPTICS, 1977, 54 (10): : 699 - 702
  • [35] INCREASING NEED FOR STANDARDIZATION
    TOVELL, RM
    MCCORMICK, JMA
    ANESTHESIA AND ANALGESIA, 1963, 42 (01): : 70 - &
  • [36] THE NEED FOR STANDARDIZATION OF PECTIN
    MOTTERN, HH
    FOOD TECHNOLOGY, 1949, 3 (01) : 34 - 35
  • [37] Screening for IgG Antinuclear Autoantibodies by HEp-2 Indirect Fluorescent Antibody Assays and the Need for Standardization
    Copple, Susan S.
    Giles, S. Rashelle
    Jaskowski, Troy D.
    Gardiner, Anna E.
    Wilson, Andrew M.
    Hill, Harry R.
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2012, 137 (05) : 825 - 830
  • [38] Tacrolimus metabolite cross-reactivity in different tacrolimus assays.
    Murthy, JN
    Davis, DL
    Yatscoff, RW
    Soldin, SJ
    CLINICAL CHEMISTRY, 1998, 44 : A95 - A95
  • [39] PROPOSALS FOR STANDARDIZATION OF TOTAL PROTEIN ASSAYS
    PETERS, T
    CLINICAL CHEMISTRY, 1968, 14 (12) : 1147 - &
  • [40] PROGRESS IN STANDARDIZATION OF TOTAL BILIRUBIN ASSAYS
    DOUMAS, BT
    BAYSE, DD
    MCCOMB, RB
    PERRY, BW
    SCHAFFER, R
    CLINICAL CHEMISTRY, 1981, 27 (06) : 1036 - 1036